Loading...
HomeMy WebLinkAbout01275 • • GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 2014 Blake Avenue Glenwood Springs, Colorado 81601 Phone (303) 945 -8241 REPAIR OR ALTERATION OF AN EXISTING SYSTEM RE -ISSUE OF 1192 (voided) NO FEE REQUIRED This does not constitute INDIVIDUAL SEWAGE DISPOSAL PERMIT r2 1275 a building or use permit. Owner Union 011 System Location Licensed Installer Schmuesser & Associates Conditional Construction approval is hereby granted for a 2 ,000 gallon per day operational level. — Septic Tank or — Aerated treatment unit. Absorption area (or dispersal area) computed as follows: Pere rate of one inch in — minutes requires a minimum of — sq. ft. of absorption area per bedroom. Therefore the no. of bedrooms — x — sq. ft. minimum requirement = a total of — sq. ft. of absorption area. May we suggest June 28, 1982 Engineered Plans and Specifications by Schmueser & Associates, Inc. approved for use up to 2,000 gpd. Loading in excess of 2,000 gpd will require site location R* at.pit,val NKR thy Cut JLadv Depart-moot Oi'}FRPIRr 11ca1Lh p.l... Lo aBc. Date: 2/18/83 from ANAL APPROVAL OF SYSTEM:1� -��� / f No system shall be deemed to be in compliance with the Sewage Disposal Laws until the assembled system is approved prior to cover- ing any part. Septic Tank access for inspection and cleaning within 12" of ground surface or aerated access ports above ground surface. Proper materials and assembly. Trade name of septic tank or aerated treatment unit. Adequate absorption (or dispersal) area. Adequate compliance with permit requirements. Adequate compliance with County and State regulations /requirements. X Other verification by Schmueser & Associates, Inc. of installation and constaa- tion to plans and specifications approved. Date 2/18/83 �- y 1l2CPXX Inspector RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE 'CONDITIONS: 1. All installation must comply with all requirements of the County Individual Sewage Disposal Regulations, adopted pursuant to au- thority granted in 66.44 -4, CRS 1963, amended 66 -314, CRS 1963. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Connection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a viola- tion of a requirement of the permit and cause for both legal action and revocation of the permit. 3. Section III, 3.24 requires any person who constructs, alters, or installs an individual sewage disposal system in a manner which in- volves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense (5500.00 fine — 6 months in jail or both). Applicant: Gran Copy Department: Plnk Copy / GARFIELD COUNTY / DEPARTMENT OF DEVELOPMENT PLANNING: 9458212 / ENVIRONMENTAL HEALTH: 945 -2339 / BUILDING: 945-8241 February 17, 1983 Mr. Thomas D. Kuebrich • Water Quality Specialist Union Oil Company of California 2777 Crossroads Boulevard, Suite 100 Grand Junction, CO 81501 Dear Mr. Kuebrich: Attached is the approved Garfield County Individual Sewage Disposal System Permit Number 1275 for the Lindauer Ranch area wastewater system. This permit is issued based on plans and specifications by Schmueser and Associates, Inc., dated June 28, 1982 and the subsequent verification of installation by the same firm. In confirmation of your recent letter, the permit is valid for up to 2,000 gallons per day operation level. Any amount in excess of 2,000 gpd will require site location approval from the Colorado Department of Health, Water Quality Control Division. Thank you for your cooperation and, if you have any questions, please call. Very truly yours, Edward L. Feld Environmental Health Officer ELF /eh Att. x.c. John Blair, District Engineer Colorado Department of Health Scott Leslie, Schmueser & Assoc. 2014 BLAKE AVENUE GLENWOOD SPRINGS, COLORADO 81601 r GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 2014 Blake Avenue Glenwood Springs, Colorado 81601 Phone (303) 945-8241 REPAIR - NO FEE REQUIRED J I � This oes not consti INDIVIDUAL SEWAGE DISPOSAL PERMIT 4O 92 � abuilding d oruseper Owner Union 011 • • System Location . . :. r . — . . _ Licensed Installer Schmuesser & Associates - (/ )• a A Conditional Construction approval is hereby granted for a ' 1 11 (� (� XXX ' Septic Tank or Aerated treatment unit. �J 1 Absorption area (or dispersal area) co •.ute. as f.11ows. Perc rate of one inch in minute r• • -s a minimum o sq. ft. of absorption area per bedroom. to Therefore the no. of bedrooms x sq. ft. minimu requirement = a total of sq. ft. of absorption area / May we suggest Date In •ector \I FINAL APPROVAL OF S TEM: No system shall be deemed • be in compliance w th the Sewage'Disposal Laws until the assembled system is approved prior to cover- ing any part. Septic Tank acce for inspection and cleaning within 12" of ground surface or aerated access ports above ground surface. • Proper materials and a • bl Trade name of septic tank or aerated treatment unit. Adequate absorption (or dispersal) area. Adequate compliance with permit requirements. Adequate compliance with County and State regulations /requirements. Other Date Inspector RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE "CONDITIONS: 1. All installation must comply with all requirements of the County Individual Sewage Disposal Regulations, adopted pursuant to au- thority granted in 66.44.4, CRS 1963, amended 66 -3 -14, CRS 1963. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Connection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a viola tion of a requirement of the permit and cause for both legal action and revocation of the permit. • 3. Section III, 3.24 requires any person who constructs, alters, or installs an individual sewage disposal system in a manner which in- volves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense (5500.00 fine — 6 months in jail or both). Applicant: Green Copy Department: Pink Copy INDIVIDUAL_ HOME SEWAGE TREATMENT SYSTEMS APPLICATION PAGE TWO OWNER OfJ /OA) C)/L, ADDRESS G+St9 Z a PHONE APPLICANT _ ADDRESS PHONE CONTRACTOR ScyMv�c c � d�c, t3 ADDRESS 3o I ✓ ^ ,S 61494A4po S`'C' . PHONE 1 IS PERMIT FOR: ( ) New Installation (X) Alteration ( ) Repair Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable buildings, location of potable water wells, soil percolation test holes, soil profiles in test holes. LOCATION OF PROPOSED FACILITY: County 00.42 Near what City or Town f44 _ ____ Lot Size Legal Description L/4/O402 MA/C4 /I f WASTES TYPE: ( ) Dwelling ( ) Transient Use �) Commercial or Institutional ( ) Non - domestic Wastes ( ) Other - Describe: _ BUILDING OR SERVICE TYPE: OFFICd Number of Persons GC __ Number of Bedrooms 0 ( ) Garbage grinder ( ) Automatic washer ( ) Dishwasher SOURCE AND TYPE OF WATER SUPPLY: QS) well ( ) spring ( ) stream or creek Give depth of all wells within 180 feet of system: /6At If supplied by community water, give name of supplier: GROUND CONDITIONS: Depth to bedrock: /'* 7Z$ J /0' Depth to first Ground Water Table: /Beef 13/ v' /0 Percent ground slope: DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: /S /N /GfS _ Was an effort made to connect to community system? 40 TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: Ic Septic TanKt)4STMXr> ( ) Aeration Plant ( ) Vault ( ) Vault Privy ( ) Composting Toilet ( ) Recycling, potable use ( ) Pit Privy ( ) Incineration Toilet ( ) Recycling, other use ( ) Chemical Toilet ( ) Other - Describe: FINAL DISPOSAL BY: (>Q Absorption Trench, Bed or Pi 01/44.Yr) ( ) Evapotranspiration ( ) Underground Dispersal ( ) Sand Filter ( ) Above Ground Dispersal ( ) Wastewater Pond ( ) Other - Describe: _ 2ff _ , PAGE THREE �L EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? )V0 SYSTEM IS DESIGNED FOR So 00 GALLONS. PER DAY If the system to be designed by a Registered Professional Engineer (RPE), state rate of absorption in test holes shown on the location map, in minutes per inch of drop in water level after holes have been soaked for 24 hours: - Poet Tat .. 6 67 m m/ ve4 - SOIL PERCOLATION TEST RESULTS: , Minutes 6.7. per inch in hole No. 1 Minutes 63) per inch in hole No. 3 Minutes '20 per inch in hole No. 2 Minutes per inch in hole No. Name, address, and telephone of RPE who made soil absorption tests: u 171 ` jeoov 3a cci ( /roar - s% oO/wah 564 d° 9/f -SYV Name, address, and telephone of RPE responsible for design of the system ;. Applicant ackrowledges .that.the_completeness the application is conditional upon such further mandatory and additional tests and reports as may be required . by the local health department to be made and furnished by the applicant or by the local health department for purposes of the evaluation of the application; and the issuance of the permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations adopted under Article 10, Title 25, C.R.S. 1973 as amended. The undersigned hereby certifies that all statements made, information and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes issuing the permit applied for herein. I further understand that any falsification or misrepresentation may • result in the denial of the application or revocation of any permit granted based upon said application and in legal action for perjury as provided by law. tS }ki6Th--- Date ,__C 2 8 - g2,. Signed PLEASE DRAW AN ACCURATE MAP TO YOUR PROPERTY PAGE FOUR PLOT PLAN AND DESIGN FEATURES: Include by measured distance location of wells, springs, potable water supply lines, cisterns, buildings, property lines, subsoil drains, lake, water course, stream, dry gulch and show location of proposed system by direction and distance from dwelling or other fixed reference object, and additional submissions in support of this application such as data, plans, specifications, statements and commitments. (SCE /377AM 7 At er a0 Union Energy Mining Division • Union Oil Company of California 2777 Crossroads Boulevard, Suite 100 Grand Junction, Colorado 81501 Telephone (303) 243 -0112 um idon RECEIVED FEB 1 , James S. Cloninger February 11, 1983 Manager of Administrative Services Mr. Ed Feld Garfield County Sanitarian 2014 Blake Avenue Glenwood Springs, Colorado 81601 Dear Mr. Feld: Per your request, enclosed are the most recent design drawings for the Lindauer Leach Field sewage system at our shale oil project. I understand from our phone conversation that the inspections performed by our installation contractor are suf- ficient, and that upon receipt of the enclosed drawings you will reissue the permit for this leach field sewage system at the 2,000 gpd operation level. I understand that if we wish to operate the sewage system in excess of the 2,000 gpd limit, then we must go through the site application process with the Colorado Department of Health. If you have any questions or need further information please call. Sincerely, Thomas D. Kuebrich Water Quality Specialist TDK:tw Enclosure cc: John Blair, CDH - w /enc. T. L. Larson w/o enc. W. G. Volk w/o enc. G. C. Dohm w/o enc. SCHMUESER S ASSOCIATES • • 1 I • 201 CENTENNIAL STREET SUITE 306 GLENWOOD SPRINGS, CO 81601 (303) 945.5468 . January 25, 1983 "' - A ` G 1933 Union Oil Company 2777 Crossroads Boulevard Suite 100 Grand Junction, Colorado 81501 Attn: Mr. Jerry Dome Re: Lindaur Ranch Wastewater System Dear Jerry, Enclosed please find our inspection report for the leachfield we installed at the Lindaur Ranch last summer. I have also enclosed a copy of the drawings which show the maintenance building connecting line to this leachfield. If you have any questions regarding this or other matters, please do not hesitate to call. Sinc rely, ' Scott Leslie Operations Consultant SL:sh Enclosure cc: Tom Kuebrich -Union Oil Company Ed Feld - Garfield County Sanitarian I I I �_ t∎ • "' ° oa ts INTER-OFFICE COMMUNICATION n , , I ASSOCUTCSI TO: Scott Leslie DATE: June_ 30, 1982 FROM: Bob Frazier SUBJECT: Lindauer Waste Water System, B2063A This is to confirm that the Lindauer Waste Water System has been constructed as per the plans and specifications shown on the Lindauer Sewer System As Built drawings of 6/28/82. The leach field has been cerrect7 located and properly sized, as are future tie -in locations, piping, manhole and inspection port. The area has been closed to vehicle traffic and a temporary barrier has been installed at the east side of the leach field. BF xc: 82063A COLORADO DEPARTMENT OF HEALTH Richard D. Lamm 114 Frank A. Traylor, M.D. Governor 1 7 6 Executive Director RECEI r , t January 4, 1983 ` VFW �l ` !,,33 MN_ 0.� 4, Mr. Thomas D. Kuebrich Union Oil Company of California 2777 Crossroads Boulevard, Suite 100 Grand Junction CO 81501 Re: Lindauer Ranch Wastewater Treatment Facility, Garfield County Dear Tom: This letter is a follow -up of our phone conversation concerning the wastewater treatment facilities for the Union offices at the old Landauer Ranch. The facility was repaired this past year through a repair permit issued by Garfield County. Recently, a request was made to allow additional connections to the system. The addition would bring the total daily flow to 1800 gpd. Ed Feld, Garfield County Sanitarian, asked that the Colorado Department of Health take responsibility for approval of the system if the system is to be used for more than 2000 gpd as per our regulations. The system built under the repair permit is large enough to handle more than 2000 gpd. If Union 011 Company plans to expand their offices at Lindauer Ranch such that more than a 2000 gpd sewage flow would result, then site application and design approval must be obtained from the'Colorado Department of Health. If you have any questions, please call me. Sincerely, FOR DIRECTOR, WATER QUALITY CONTROL DIVISION PC4- John R. Blair • District Engineer JRB /zp cc: Ed Feld, County Sanitarian Scott Leslie, Schmueser & Associates Water Quality Staff, Denver Dick Bowman, West Slope Supervisor 125 NORTH 8TH STREET, GRAND JUNCTION, COLORADO 81501 PHONE (303)245 -2400 of cola COLORADO DEPARTMENT OF HEALTH Richard D. Lamm \ �C — 'rte * Frank A. Traylor, M.D. Governor `1 g 7 6 Executive Director January 5, 1983 Pe cEIV E p JAN , tS 1933 Mr. Scott Leslie Schmueser & Associates, Inc. 201 Centennial Street, Suite 306 Glenwood Springs CO 81601 Re: Addition to Union Oil Company of California's Lindauer Ranch Wastewater Treatment Facility, Garfield County Dear Scott: I have reviewed the plans for the 1500 gpd addition to the wastewater treat— ment facility at Union Oil Company's office at the old Lindauer Ranch. The plans appear to meet the Colorado Department of Health design criteria except . for the 13.57% slope on the first section of line out of the new septic tank. Normally this slope should be reduced by the use of a drop manhole. Since the line only carries septic tank effluent, no adverse conditions should develop in this situation. I have informed Union Oil Company that any increase in usage over 2000 gpd must first be proceeded by site application and design approval. If a site application is approved, then I would like to see the as —built plans and design calculations for the existing system built under a Garfield County - repair permit. The plans and design will be reviewed to determine if the system can be used for more than 2000 gpd. If you have any questions, please call me. Sincerely, FOR DIRECTOR, WATER QUALITY CONTROL DIVISION John R. Blair District Engineer JRB /zp cc: Ed Feld, County SanitarianV Tom Kuebrich, Union Oil Company Water Quality Staff, Denver Dick Bowman, West Slope Supervisor 125 NORTH 8TH STREET, GRAND JUNCTION, COLORADO 81501 PHONE (303)245 -2400 INDIVIDUAL HOME SEWAGE TREATMENT SYSTEMS APPLICATION PAGE TWO OWNER 7v K.ti - - -- ADDRESS 6"3 JZAk?D'v C: _ PHONE APPLICANT - -- ADDRESS — PHONE ____________ CONTRACTOR SC H/IN C p , d /tcitei /1'I2t _ - - - - -- ADDRESS 3o I C{NIix rvnz _5% Cftc S L'c PHONE %yf 0"6 IS_PERMIT FOR: ( ) New Installation L Alteration ( ) Repair Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable buildings, location of potable water wells, soil percolation test holes, soil profiles in test holes. LOCATION OF PROPOSED FACILITY: County 61";FI0.. — - -_— Near .what City or Town thigic/l{ _ _ —_— —_ - -Lot Size ,— Legal Description _L /A%ojy _(.9,vC) /V-crn WASTES TYPE: ( ) Dwelling ( ) Transient Use Commercial or Institutional ( ) Non - domestic Wastes ( ) Other - Describe: BUILDING OR SERVICE TYPE: Cff/cc' Number of Persons 3S Number of Bedrooms C ( ) Garbage grinder ( ) Automatic washer ( ) Dishwasher SOURCE AND TYPE OF WATER SUPPLY: (CG) well ( ) spring ( ) stream or creek Give depth of all wells within 180 feet of system: /i-Ck If supplied by community water, give name of supplier: GROUND CONDITIONS: Depth to bedrock: "4= 7A✓ /C' Depth to first Ground Water Table: /fi pa/ /0/ Percent ground slope: DISTANCE 10 NEAREST COMMUNITY SEWER SYSTEM: /5 Was an effort made to connect to community system? -_ 40 TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: (x) Septic Tan1049 74) ( ) Aeration Plant ( ) Vault ( ) Vault Privy ( ) Composting Toilet ( ) Recycling, potable use ( ) Pit Privy ( ) Incineration Toilet ( ) Recycling, other use ( ) Chemical Toilet ( ) Other - Describe: FINAL DISPOSAL BY: ('1 Absorption Trench, Bed or Pil(fillutgr�( ) Evapotranspiration ( ) Underground Dispersal ( ) Sand Filter ( ) Above Ground Dispersal ( ) Wastewater Pond ( ) Other - Describe: -- , ; . PAGE THREE ; WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? �` _ — SYSTEM IS DESIGNED FOR SC C GALLONS PER DAY If the system is to be designed by a Registered Professional Engineer (RPE), state rate of absorption in test holes shown on the location map, in minutes per inch of drop in water level after holes have been soaked for 24 hours: 1 -) D ( 11.-ST 6 67 r/.✓ /iyei/ . - SOIL PERCOLATION TEST RESULTS: Minutes C.LX per inch in hole No. 1 Minutes (..7 per inch in hole No. 3 Minutes - 20 per inch in hole No. 2 Minutes per inch in hole No. — Name, address, and telephone of RPE who made soil absorption tests: £C "-) 6or-0 zti 3og C ci v aA/A/ow sr 6 KCV.41v0 &3C 6 Co 7 iff - f Name, address, and telephone of RPE responsible for design of the system; Applicant acknowledges .that.the _ cpmpleteness of the application is conditional upon such further mandatory and additional tests and reports as may be required by the local health department to be made and furnished by the applicant or by the local health department for purposes of the evaluation of the application; and the issuance of the permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations adopted under Article 10, Title 25, C.R.S. 1973 as amended. The undersigned hereby certifies that all statements made, information and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes issuing the permit applied _ for herein. I further understand that any falsification or misrepresentation may , result in the denial of the application or revocation of any permit granted based upon said application and in legal action for perjury as provided by law. Date S •Z KZ Signed J • PLEASE DRAW AN ACCURATE MAP TO YOUR PROPERTY PAGE FOUR PLOT PLAN AND DESIGN FEATURES: Include by measured distance location of wells, springs, potable water supply lines, cisterns, buildings, property lines, subsoil drains, lake, water course, stream, dry gulch and show location of proposed system by direction and distance from dwelling or other fixed reference object, and additional submissions in support of this application such as data, plans, specifications, statements and commitments. O ar- /i7m74C4n7 13t. mint, )