Loading...
HomeMy WebLinkAbout01624 • GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT /di . I . t . 109 8th Street Suite 303 ace- Q� Glenwood Colorado 81601 Phone ne (30 (303) ) 945 - 8212 Y tr INDIVIDUAL SEWAGE DISPOSAL PERMIT :' - 1 624 abuildThis does not constitute ingorusepermi Owner Bill Vezzoso System Location 0111 Widow Lane, Carbondale Licensed Installer ____ °Wrie ' Conditional Construction approval is hereby granted for a gallon Septic Tank or _ _Aerated treatment unit. Absorption area (or dispersal area) computed as follows: Perc rate of one inch in ___ minutes requires a minimum of sq. ft. of absorption area per bedroom. Therefore the no. off bedrooms // / x �/ _sq. ft. minimum � requirement = a total of sq. ft. of absorption area. May we suggest: Aek a c_4zie if i ecby s4en, d Pa ccleciesso e / q • E, 6 lUb hY b es et r kc ti tee{1 Date._ _ Ly c G� g � O __ . Inspector i. _ - La / J FINAL APPROVAL OF SYSTEM: No system shall be deemed to be in compliance with the Sewage Disposal Laws until the assembled system is approved prior to cover• ing any part, pa r� LC .. Septic Tank access for inspection and cleaning within 12" of ground surface or aerated access ports above ground p PS'. surface. - CP ..gi , Proper materials and assembly. n 0/" Trade name of septic tank or aerated treatment unit. / 7410 `/st /2S . ej ?G r . � S C9 � / ly�r�8 ,�CC11 //''�' Ade quate absorption (or dispmsall area. -- SL_�... Adequate compliance with permit requirements. C � Adequate compliance with County a d State eg ation; /requirements. -- __L-r-. Other /9e a f d" "mac? esylr, �p CC v Date � �� _ P t� ....-- ------ Inspector _r /1. -- -- RETAIN WITH RECEIPT RECORD', CONSTRUCTION SIT *CONDITIONS: 1. All Installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit Is valid only for connection to structures which have fully complied with County zoning and building requirements. Connection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation of a requirement of the permit and cause for both legal action and revocation of the permit, 3. Any person who constructs, alters, or installs an individual sewage disposal system In a manner which involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine — 6 months In jail or both.). Applicant: Green Copy Department: Pink Copy Application ''. 'INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION Approval by OIJNER / /,5., s d County Official: ADDRESS O /// W, / /n„ 1 at 6oAI,e a / PHONE 9L /,.5 - ,r CONTRACTOR Sleye ADDRESS PHONE PERMIT REQUEST FOR: ( New Installation ( ) Alteration ( ) Repair Attach separate sheets r report showing entire area with respect to surrounding areas, topography of area, habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes. (See page 4.) LOCATION OF PROPOSED FACILITY: County 6 g g Near what City of Town_ nlylle4/,p Lot Size S,;2247 Legal Description J4( 1��., 4„ro30A 5„b au, WASTES TYPE: ('() Dwelling �� `` ( ) Transient Use ( ) Commercial or Institutional ( ) Non - domestic Wastes ( ) Other - Describe BUILDING OR SERVICE TYPE: Number of bedrooms 3 Number of persons T if ( ) Garbage grinder ( ) Automatic washer (/() Dishwasher SOURCE AND TYPE OF WATER SUPPLY: (1) well ( ) spring ( ) stream or creek Give depth of all wells within 180 feet of system: If supplied by community water, give name or supplier: GROUND CONDITIONS: Depth to bedrock: Depth to first Ground Water Table: Percent ground slope: DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: Was an effort made to connect to community system? TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: ( $ Septic Tank ( ) Aeration Plant ( ) Vault ( ) Vault Privy ( ) Composting Toilet ( ) Recycling, potable use ( ) Pit Privy ( ) Incineration Toilet ( ) Recycling, other use ( ) Chemical Toilet ( ) Other - Describe: FINAL DISPOSAL BY: ( ) Absorption Trench, Bed or Pit ( ) Evapotranspiration ( ) Underground Dispersal ( ) Sand Filter (K) Above Ground Dispersal ( ) Wastewater Pond ( ) Other - Describe: �y WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? (gin ) Page 2 r • SOIL PERCOLATION TEST RESULTS: (To be completed by Registered Professional Engineer.) 'Minutes per inch in hole No. 1 Minutes per inch in hole No. 3 Minutes per inch in hole No. 2 Minutes per inch in hole No. Nance, address and telephone of RPE who made soil absorption tests: Name, address and telephone of RPE responsible for design of the system: Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional tests and reports as may be required by the local health department to be made and furnished by the applicant or by the local health department for purposes of the evaluation of the application; and the issuance of the permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations adopted under Article 10, Title 25, C.R.S. 1973, as amended. The undersigned hereby certifies that all statements made, information and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes of issuing the permit applied for herein. I further under- stand that any falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based upon said application and in legal action for per- jury as provided by law. Date 4 -42- O X - Signed PLEASE DRAW AND ACCURATE MAP TO YOUR PROPERTY aststt.54fir _33 C Rr0A 1 4 sk- S 9r .. S. ffi Page 3 • PLOT PLAN AND DESIGN FEATURES: Include by measured distance location of wells, springs, potable water supply lines, cisterns, buildings, property lines, subsoil drains, lake, water course, stream, dry gulch and show location of proposed system by direction and distance from dwelling or other fixed reference object, and additional submissions in support of this application such as data, plans, specifications, statements and commitments. r ept;e 1 �a o ce 1 Page 4 MIME Wright Water Engineers, Inc. DENVER OFFICE 1 ULSA OFFICE GLENWOOD SPRINGS OFFICE 2490 West 260h Ave., Suite 55 A 201 West 5th St., Suite 130 818 Colorado Avenue Denver, Colorado 80211 Tulsa, Oklahoma 74103 P.O. Box 219 (303) 480 -1700 (918) 584 -7136 Glenwood Springs, Colorado 81602 (303) 945-7755 August 4, 1988 Denver Direct Line: 893 -1606 Mr. William Vezzoso 0111 Willow Lane Carbondale, CO 81623 Re: Vezzoso Wastewater Treatment System Dear Bill: The following design for an individual on -site wastewater treatment and disposal system for a four bedroom single family home on Lot C in the Harris Subdivision near Carbondale is provided at your request. The design is based upon Garfield County requirements and physical site conditions. A field inspection of the site was made on July 22, 1988. Observations were made of three test holes at the leach field location. The location of the house with respect to the surrounding surface elevation will necessitate a pumped effluent system. The septic tank and soil absorption mound is located southwest of the house. The following parameters were used in the design of the system: o 4 bedroom single family home o Design flow rate = 150 gpd/bedroom o Natural ground slope less than 5% o Bedrock not encountered (assume greater than 4 feet) o Water table not encountered (assume greater than 24 inches but less than 48 inches at high water) o Minimum detention time in septic tank 30 hours The sewage effluent flow is calculated to be 600 gpd based on 4 bedrooms at 150 gpd/bedroom. A peak day multiplier of 1.5 was used for design purposes. Mr. William Vezzoso • August 4, 1988 Page 2 Septic Tank The septic tank shall be a prefabricated concrete or polyethylene tank with a minimum liquid capacity of 1200 gallons. The tank shall be installed in accordance with Garfield County requirements and shall be at an elevation capable of receiving sewage flow by gravity. Dosing Tank and Pump Septic tank effluent shall enter a water tight polyethylene or concrete dosing tank with a capacity of 300 gallons, which is approximately twice the volume of the pipe laterals. A low head submersible pump rated at 35 -50 gpm at 5 ft. of head, such as Hydromatic Model CW25 or equal, shall be installed in the dosing chamber. Soil Absorption Mound The soil absorption mound shall be as shown on the attached figures 7 -10, 7 -11 and 7 -13 which are from the EPA Design Manual for On -site Wastewater Treatment & Disposal Systems. The mound shall be located on natural ground within 25 feet of the dosing chamber. Topsoil shall be plowed or raked with backhoe teeth prior to placing the mound fill. Fill material shall be medium textured sand meeting the following grada- tion: Sieve Size Percent Passing #4 100 #10 75 -90 #16 35 -50 #50 15 -25 #200 0 -10 Results of a gradation test shall be provided by the supplier. For design purposes the sand shall be assumed to have a infiltration rate of 1.2 gpd /ft.2. Mr. William Vezzoso August 4, 1988 Page 3 The absorption bed material shall be porous media consisting of graded • gravel sized between 3/4 inch and 2 -1/2 inches. Fill material'and bed material should be readily available from local suppliers. The area of the absorption bed shall be 750 square feet based on a peak day flow of 900 gpd and an absorption rate of 1.20 gpd /ft. The mound shall be constructed on a relatively shallow grade and the percolation rate of the natural soils is relatively high. G1( ([/ The base are of the mound shall be a minimum of 1125 ft. based on 900 gpd and 0.8 gpd /ft. Mound dimensions for the system are as shown below. Refer to figure 7 -13 for location of dimensions. A = 18 ft. B = 42 ft. C = 1 ft. (minimum) E = 1 ft. (minimum) F = 0.75 ft. G = 1 ft. H = 1.5 ft. I = 12 ft. j1 ' J = 6 ft. (1) K = 9 ft. (1) L = 60 ft. W 36 ft. (1) actual dimension will vary slightly to meet 3:1 slopes The mound shall have six distribution laterals consisting of 4 inch dia- meter PVC drain tile placed 36 inches O.C. The laterals shall be connected with a 4 inch diameter PVC header on both ends. The distribution of the effluent to the mound will be in a 4 inch diameter PVC pipe. The purpose of the design and letter report is to assist you in obtaining a Garfield County permit for an on -site individual wastewater treatment system. Mr. William Vezzoso August 4, 1988 Page 4 If you have any questions please contact me at your convenience. . Very truly yours, WRIGHT WATER ENGINEERS, INC. S. B 7 • ,, P.: � n :c lb.; a i PSB/bdm 1 l ` >" ^ r : • , °• • , 881 - 027.240 ',''° c ?d. `..•' , , yp fit • • FIGURE 7 -11 DETAILED SCHEMATIC OF A MOUND SYSTEM Layer of Straw or Marsh Hay 1' 4" Perforated Sandy Loam Soil '� Laterals 4 `• • Diversion for ; �� °'�•.:. Surface Water Inlet Pipe j• Clean Rock _.,E,�' 6" Topsoil -- Max 1 •: • Sand Fill' _ '.,,,�, V4 • — -. ! _.__- .. - -' ,- -:: y :.:!1,� -•o-:/ -sex s •.a.r sd • _�.. Sod •''` Slo : o• " _ ; . Broken Up' . 7.2.4.2 Application a. Site Considerations Site criteria for mound systems are summarized in Table 7 -7. These criteria reflect current practice. Slope limitations for mounds are more restrictive than for conventional systems, particularly for mounds used on sites with slowly permeable soils. The fill material and na- tural soil interface can represent an abrupt textural change that re- stricts downward percolation, increasing the chance for surface seepage from the base of the mound. • 241 • FIGURE 7 -10 TYPICAL MOUND SYSTEMS Cap I Straw, Hay or Fabric { Distribution Lateral Fill —\ Absorption Bed Topsoil M L C /nL.1 r / .Plowed Layer of Top Soil Slope ope - - ar'.. w.rs• .al!►im► "7 - 11/ =-:Rock Strata or Impermea•le Soil Layers - = (a) Cross Section of a Mound System for Slowly Permeable Soil on a Sloping Site. Cap Straw, Hay or Fabric Distribution Lateral Fill �� d Absorption Bed Topsoil ..- 1 , y j ::: • u; 3 e 7:::: Ii \ 1 I I I I \ V A \ \ Plowed Laver of Top Soil r trrrrrrrlrrr���� 1 I I: \ \ \ \ \ \ Permeable Soil P r fi l irri `inT . _ l ! F r 1 !.. IT' Water Table or Creviced Bedrock • (b) Cross Section of a Mound System for a Permeable Soil, with High Groundwater or Shallow Creviced Bedrock 240 FIGURE 7 -13 MOUND DIMENSIONS Straw or Marsh Hay Perforated Clay Fill or Medium Sand Fill Pipe Topsoil T r - Topsoil • � % 1 I E f ID f opsoil ✓ -]me'° • Slope Subsoil Plowed Surface 3/4-21/2 in. Rock (A) Cross Section w A ) J Distribution I i Laterals I Y k B Bed of 1 3/4" -21/2" Rock 1 T Slope K J (B) Plan View 247 i. purr ,c) /JOf nee lr/! YU'�o /a7%0., 'et S1 /ter - s ewQ J 'C o%jlo3o s -r► , � ke Q O Y tM�f', II n 4 ( o 07' en b been.bSo07° t'n 31-ea SO. So wo u ld �� p c 'e444 o 44 on e 11o4n40-e do)/arS 4/4 /rzz6So 8861 i 9fltl V s rr. �i ^ /42i/ FUND 6kwa"( ITEM DESCRIPTION /c/e.nINP (services, supplies, eta.) ACCOUNT o _ oI - 5�- oo po - 3� -r/ moot $ 600 air 0 ,1 / Gt) d une 6 40.06- O O .. W fl)fr1 J rt' TOTAL $ CX O VENDOR # (etztad tua rn Irdiy INVOICE 0 APPROVED FOR 4PAYMENT DATE nein CHECKED BY ACCOUNTING OFFICEit1a s) (Initials)