�_ GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT Permit N 2 2 9 6 r
r 109 8th Skeet Suite 303 ' Assessor's Parcel No.
Glenwood Springs, Colorado 81601 4t 9
Phone (303) 945 -8212 t
This does not constitute
INDIVIDUAL SEWAGE DISPOSAL PERMIT a building or use permit. t
Y ,
PROPERTY '
T t
ti
Owner's Name Steve & Kim Ochio Present Address 4366 CR 100 Carbondale Phone 963 -9791
1
System Location County Road 100, Carbondale (+{
Legal Description of Assessor's Parcel No.
i 4
i
SYSTEM DESIGN 1 *
I I
S
(1 / /i /000 Septic Tank Capacity (gallon) Other {
7 . 6 Percolation Rate (minutes /inch) Number of Bedrooms (or other) 3
Required Absorption Area - See Attached writ J An fort T O 4 a NC H . pc S
�l r jI7 d 117 I 34X0 ? 0 1 _
Special Setback Requirements: -'2 $' CJ ` f J `� _ r
Date ( l f 941 Inspector . Mi
/ 42/ _
1.
FINAL SYSTEM INSPECTION AND APPROVAL (as installed)
Call for Inspection (24 hours notice) Before Covering Installation
System Installer - 3-6 E 7 CO<d1 C I0 p
Septic Tank Capacity /147Depe; r 0 1
Septic Tank Manufacturer or Trade Name -b p&el.w.rd
S
Septic Tank Access within 8" of surface
C
f7
Absorption Area 3 /7 fJ 4 S. f /Y et' Yore. i 1'
9
t
Absorption Area Type and /or Manufacturer or Trade Name f 1t a , / TiE'ri 7h j r
Adequate compliance with County and State regulations /requirements 44 -s
f
Other
. `
Date IL: - 9 Inspector «'. L/ K .ad:r c---
RETAIN WITH RECEIPT RECORDS AT COONST SITE
*CONDITIONS:
1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter
25, Article 10 C.R.S. 1973, Revised 1984.
2. This permit Is valid only for connection to structures which have fully complied with County zoning and building requirements. Con -
nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a
requirement of the permit and cause for both legal action and revocation of the permit.
3. Any person who constructs, alters, or installs an individual sewage disposal system in a manner which involves a knowing and material
variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine — 6
months in jail or both).
Applicant: Green Copy Department: Pink Copy I F
OCAS` o
3 Q2 p ,rnc• rn9rc _ Ft• c
Pr AVr
p245 X 75 /i c X /..5 r C73 O P°
Gs x2. = 3 ?7,3
3`17,30 x Go% : 7. C55 Cfrs> G3G
G SCo = C36 TR2NCM re's (Pro re's
NricfnAfan - 3 /9 e /7 3 $0 # 20
con NGfork TiVere s o n. ,o4
38 .o * 23 re s
k-C9-1K
Application
JNDIVIDT JAI , SEWAGE DISPOSAI. SYSTEM APPT JCATION Approval By
County Official
OWNER S }cuc a,na Kph, OCM0 /� /J///
ADDRESS 4Prb CCU& 110.2d ,W. (dit/rnc/444 l() P OZ PHONE VG -39n/ /
CONTRACTOR/,//! / 6% r 8'A
ADDRESS PHONE
PERMIT REQUEST FOR: k0 New Installation () Alteration () Repair
Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area,
habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes
(See page 4).
J.00ATION OF PROPOSED FACII .ITY : County , herA-- d
Near what City or Town (1 afzbondak- Lot Size { 19 03 w1C4C S
Legal Description P /Cast .5'. ki hick, - G //ac_Ard
WASTES TYPE • x3 Dwelling ( ) Transient Use
( ) Commercial or Institutional ( ) Non - domestic Wastes
( ) Other - Describe
BUILDING OR SERVICE TYPE: rim //7 Dix 1in9
Number of bedrooms , '3 J Number of' persons Z
Garbage grinder (k) Automatic Washer (D Dishwasher
,SOT JRCE AND TYPE OF WATER SI JPPI,Y: mQ well () spring () stream or creek
Give depth of all wells within 180 feet of system: /V /-
If supplied by community water, give name of supplier: /V /4
(TROTIND CONDITIONS:
Depth to bedrock:
Depth to first Ground Water Table:
Percent ground slope:
DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: None: in Ale /I
Was an effort made to connect to community system? NO
TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED:
S Septic Tank ( ) Aeration Plant ( ) Vault
( ) Vault Privy ( ) Composting Toilet ( ) Recycling, potable use
( ) Pit Privy ( ) Incineration Toilet ( ) Recycling, other use
( ) Chemical Toilet ( ) Other - Describe:
FINAL DISPOSAL BY:
( ) Absorption Trench, Bed or Pit ( ) Evapotranspiration
( ) Underground Dispersal ( ) Sand Filter
( ) Above Ground Dispersal ( ) Wastewater Pond
( ) Other - Describe:
WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? 4(2
SOIT, PER COT ,ATION TEST REST J1 TS (To be completed by Registered Professional Engineer)
Minutes 8 per inch in hole No. 1 Minutes 8 per inch in Hole No. 3
Minutes 10 per inch in hole No. 2 Minutes per inch in Hole No. _
Name, address and telephone of RPE who made soil absorption tests; .S /rucn 1- Pay kit, P1.
tl t Co k c h r Znr so20XL4 /S¢. 6knwwi
f , s.(0 ailm/ 303 94c 9488
Name, address and telephone of RPE responsible for design of the syste
Applicant acknowledges that the completeness of the application is conditional upon such further mandatory
and additional tests and reports as may be required by the local health department to be made and furnished
by the applicant or by the local health department for purposes of the evaluation of the application; and the
issuance of the permit is subject to such terms and conditions as deemed necessary to insure compliance with
rules and regulations adopted under Article 10, Title 25, C.R.S. 1973, as amended. The undersigned hereby
certifies that all statements made, information and reports submitted herewith and required to be submitted
by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and
are designed to be relied on by the local department of health in evaluating the same for purposes of issuing
the permit applied for herein. I further understand that any falsification or misrepresentation may result in
the denial of the application or revocation of any permit granted based upon said application and in legal
action for perjury as provided by law. 70�4.
is7X1i
Date js ne /7 1/9q# Signed kiv `' lJ
'o r 007 fO s ;'/
pi .EASE DRAW AN ACCTTRATE MAP TO YOTJR PROPERTY 314 c-5 lGG
/l�prox 1 m, e off the 81 —�
3
N 3
SCHEDULE A
PROPERTY DESCRIPTION
ORDER NO: 94022571
A parcel of land being located in the Southwest Quarter of the
Northeast Quarter of Section 30, Township 7 South, Range 87 West
of the Sixth Principal Meridian, said parcel is more fully
described as follows:
Commencing at the Center Quarter Corner of said Section 30, a
Garfield County Surveyor's Brass Cap Monument;
thence North 02 degrees 45'23" East along the North -South center
line Of)said,Section 30, being the Westerlyaboundary?of the
SouthWeet'.Quarter Of the Northeast Quarter of“said'Section,
435.60 feet to the true Point of Beginning;
thence continuing along said line North 02 degrees 45'23" East
259.46 feet;
thence South 75 degrees 18'55" East, 727.29 feet;
thence North 16 degrees 51'11" East, 113.52 feet;
thence North 22 degrees 35'32" East, 207.04 feet;
thence South 89 degrees 33'29" East, 522.92 feet to a point on the
Easterly boundary of the Southwest Quarter of the Northeast Quarter
of said Section 30;
thence South 02 degrees 43'43" West, 804.86 feet to the Southeast
Corner of the Southwest Quarter of the Northeast Quarter of
said Section 30;
thence South 89 degrees 55 West, 1133.99 feet along the
Southerly Boundary of the Southwest Quarter of the Northeast
Quarter of said Section 30, being also the East -West center line
of said Section to a point 200.00 feet, North 89 degrees 55'37"
East of the Center Quarter Corner, of said Section 30, a
Garfield County Surveyors Brass Cap Monument;
thence North 02 degrees 45'23" East, parallel to the North -South
center line of said Section 30, being the Westerly boundary of
the Southwest Quarter of the Northeast Quarter of said Section,
435.60 feet to a point;
thence North 89 degrees 55'37" West, parallel to said Southerly
boundary of the Southwest Quarter of the Northeast Quarter of
said Section 30 to the True Point of Beginning.
COUNTY OF GARFIELD
STATE OF COLORADO
ALSO SOMETIMES DESCRIBED AS
LOT 2
IRENE GREEN SUBDIVISION EXEMPTION
ACCORDING TO THE AMENDED PLAT
Eorm No: OFFICE OF THE STATE ENGINEER -
GWS -25 COLORADO DIVISION OF WATER RESOURCES
818 Centennial Bldg., 1313 Sherman St., Denver, Colorado 80203
(303) 866-3581
1095
WELL PERMIT NUMBER 198794 - -_
APPLICANT DIV. 5 CNTY. 23 WD 38 DES. BASIN MD
Lot: 2 Block: Filing: Subdiv: IRENE GREEN EXEMPTION
APPROVED WELL LOCATION
GARFIELD COUNTY
STEVE & KIM OCHKO SW 1/4 NE 1/4 Section 30
4355 COUNTY RD 100 Twp 7 S RANGE 87 W 6th P.M.
CARBONDALE CO 81623
DISTANCES FROM SECTION LINES
( 303)963- 9791 2250 Ft. from North Section Line
PERMIT TO CONSTRUCT A WELL 2465 Ft. from East Section Line
ISSUANCE OF THIS PERMIT DOES NOT CONFER A WATER RIGHT
CONDITIONS OF APPROVAL
1) This well shall be used in such a way as to cause no material injury to existing water rights. The issuance of the
permit does not assure the applicant that no injury will occur to another vested water right or preclude another
owner of a vested water right from seeking relief in a civil court action.
2) The construction of this well shall be in compliance with the Water Well Construction and Pump Installation Rules
2 CCR 402 -2, unless approval of a variance has been granted by the State Board of Examiners of Water Well
Construction and Pump Installation Contractors in accordance with Rule 17.
3) Approved pursuant to CRS 37- 92- 602(3)(b)(II)(A) as a change of use of permit no. 173635 (canceled), and as the
only well on a residential site of 19.03 acres described as lot 2, Irene Green Subdivision Exemption, Garfield
County. The issuance of this permit hereby cancels permit no 173635.
4) The use of ground water from this well is limited to ordinary household purposes inside a single family dwelling.
The ground water shall not be used for irrigation or other purposes.
5) The maximum pumping rate shall not exceed 15 GPM.
6) The return flow from the use of the well must be through an individual waste water disposal system of the
non - evaporative type where the water is returned to the same stream system In which the well is located.
7) This well shall be constructed not more than 200 feet from the location specified on this permit.
a 1) 6 -7 - '
{ tJ i -.i
Jits?"--
APPROVED .
State Engineer By
Receipt No. 0370030 DATE ISSUED JUN U 9 1999 EXPIRATION DATE JUN 0 9 1996
a g60104 7 Q .h /7//7
I GEOTECHNICAL, INC. 5020 Roa 54
Glenwood Springs, CO 81601
April 28, 1994 Fax 303 945 -8454
Phone 303 945 -7988
Steve and Kim Ochko
4366 County Road 100
Carbondale, Colorado 81623 'Job No. 194 190
SiBj 6t: \Percolation Test and W.ackhoe Pit, Proposed Residen4e, 4366 County
Road 100, Garfield County, Colorado.
Dear Mr. and Mrs. Ochko:
As requested, Hepworth - Pawlak Geotechnical, Inc. conducted percolation testing and
observed backhoe pit excavations at the subject site on April 14, 1994. The findings of
our work are presented in this report. The work was done in accordance with our
agreement for geotechnical engineering services to you, dated April 5, 1994.
A new 1 1/2 story residence and leach field for septic disposal are proposed. The
percolation testing was conducted for design of an infiltration disposal system and
backhoe pits were dug near the residence for general bearing conditions.
Two pits were dug near the proposed residence and a profile pit was dug in the leach
field area as located by you. The soils encountered in the pits consisted of low density
sandy silt in the residence area (Fig. 1) and about 3 feet of silt above the basalt gravel
and cobbles in a sandy silt matrix Lathe leach field area (Fig 2). Results of
consolidation testing performed on samples taken from the building site, shown on
Fig. 3, indicate the silts are highly compressible when wetted and loaded. No free
water was encountered in the pits and the soils were slightly moist. Percolation testing
was performed in the basalt gravel cobbles in 3 shallow pits on April 15, 1994.
Considering the conditions exposed in the pits dug near the building site, spread
footings placed on the natural silt soils could undergo excessive settlement even under
Light loading if wetting of the subsoils were to occur. Bearing the footings on the silty
gravel and cobble subsoils should have relatively low settlement risk. Moving the
building site and /or deepening the bearing level to the gravel and cobble subsoils should
be considered to reduce the risk of building distress. The percolation test results are
presented in Table I. Based on the subsurface profile and the test results, the designated
leach field area should be suitable for an infiltration septic disposal system. The
average percolation rate measured is about 10 minutes per inch.
Steve and Kim Ochko
April 28, 1994
Page 2
The findings of this study are based on our observation of the soils exposed within the
pits excavated at the designated locations. The extent of the compressible silt was not
determined in the residence area. Variations in the subsurface conditions could increase
the risk of foundation movement. Additional subsurface exploration is recommended to
determine the depth of the silt and a suitable building location.
If there are any questions or if we may be of further assistance, please let us know.
Sincerely,
HEPWORTH - PAWLAK GEOTECHNICAL, INC.
00 �` (,k: 15222 ,
Steven L. Pawlak, "SE ; / a J.
Rev. By: DEH J
` O F COLO—
SLP /ro
Attachment
H - GEOTECH
HEPWORTH - PAWLAK GEOTECHNICAL, INC.
LOG OF EXPLORATORY HOLES
Job No: 194 190
Datum: Ground Surface Prepared By: LEE, H -P Geotech, Inc. Date: 04/14/94
Reviewed By: SLP, H -P Geotech, Inc. Date: 04/22/94
Type /Size of Hole: 426 Cat backhoe
Pit No: 1 Pit No: 2
Location: Residence Downhill Location: Residence Uphill
Depth,Ft. Visual Description of Depth,Ft. Visual Description of
Class. Material Class. Material
0 - 3.5 Fill Man - placed; sandy silt, 0 - 0.5 OL Topsoil; organic silt, dark
loose, brown. brown.
3.5 - 9 ML Sandy silt; firm, slightly 0.5 - 8.5 ML Sandy silt; firm, slightly
moist, light brown occasional moist, light brown, occasional
basalt cobbles, porous. basalt cobbles, porous.
Bottom of Pit @ 9 feet
Bottom of Pit @ 8.5 feet
No free water
No free water
Samnlas; Samples;
1 Fill 2" diameter hand driven liner 2 ML 2" diameter hand driven liner
4 ML 2" diameter hand driven liner 4 ML 2" diameter hand driven liner
5 ML 2" diameter hand driven liner 7 ML 2" diameter hand driven liner
7 ML 2" diameter hand driven liner
Fig. 1
HEPWORTH - PAWLAK GEOTECHNICAL, INC.
LOG OF EXPLORATORY HOLES
Job No: 194 190
Datum: Ground Surface Prepared By: LEE, H -P Geotech, Inc. Date: 04/14/94
Reviewed By: SLP, H -P Geotech, Inc. Date: 04/22/94
Type /Size of Hole: 426 Cat backhoe
Profile Pit
Location: Leach Field
Depth,Ft. Visual Description of Depth,Ft. Visual Description of
Class. Material Class. Material
0 - 1 OL Topsoil; organic silt, dark
brown.
1 - 3 ML Sandy silt; firm, slightly
moist, light brown,
occasional basalt cobbles,
porous.
3 - 8 GM Gravel with cobbles; sandy
silt matrix, medium dense,
slightly moist, light brown.
Bottom of Pit @ 8 feet
No free water
Fig. 2
•
- 0 —
- f -� Moisture Content r 6.9 percent
Dry Unit Weight = 85 pct
1
Sample or: sandy silt -200=77
feet
2
From: pit 1 @ 5 fe
' 3 �' ~___ Compression
Upon Wetting
o 1 1 1
0, 4
to
U)
L
0
U 5 I i t
6 I
7
8
f .
I I
9 o.l 1.c 10 la,
APPLIED PRESSURE — ksf
Moisture Content = 8,9 percent
Dry Unit Weight = 98 pc:
• 0 — sample of sandy silt - 200 =83
o From: Pit 2 @ 4 feet
1 _
■
2
0
Compression
trlz Upon Wetting
c 3
o
in
Ltul 0) 4
n
o
5
•
6
0.1 1.0 10 100
APPLIED PRESSURE — ksf
194 190 HEPWORTH PAWLAK SWELL- CONSOLIDATION TEST RESULTS I Fig. 3
GEOTECHNICAL, Inc.
•
HEPWORTH - PAWLAK GEOTECHNICAL, INC.
TABLE I
PERCOLATION TEST RESULTS JOB NO. 194190
HOLE NO. HOLE DEPTH LENGTH OF WATER DEPTH WATER DEPTH DROP IN AVERAGE
(INCHES) INTERVAL AT START OF AT END OF WATER PERCOLATION
(MINI INTERVAL INTERVAL LEVEL RATE
(INCHES) (INCHES) (INCHES) (MIN. /INCH)
P-1 32 15 17 11 6
11 8 3
refill
16.5 13.6 3
13.5 11 2.5
11 8.5 2.5
8.5 6.5 2
refill 16.5 14.5 2
14.5 12.5 2 8
P -2 27 15 10 6 4
6 4 2
refill
9.5 7.5 2
7.5 6 1.6
6 4.5 1.5
refill 9 7.5 1.6
7.5 6 1.5
6 4.5 1.6 10
P -3 38 15 15 6.5 8.5
6.5 3 3.5
refill
14.5 11 3.5
11 8 3
8 5.5 2.6
refill 14.5 12 2.6
12 10 2
10 R 2 8
Note: Percolation holes were dug and soaked on April 14, and the tests were conducted on April 15, 1994.