Loading...
HomeMy WebLinkAbout02544 GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT Permit 2544 109 8th Street Suite 303 Assessor's Parcel No. Glenwood Springs, Colorado 81601 Phone (303) 945 -8212 This does not constitute INDIVIDUAL SEWAGE DISPOSAL PERMIT a building or use permit. PROPERTY Owner's Name John K. Sn&bble Present Address 5970 CR 109, Carbondale Phone_1 -2636 System Location 5970 County Road 109, Carbondale Legal Description of Assessor's Parcel No. SYSTEM DESIGN Mix/ /aso Septic Tank Capacity (gallon) Other - Percolation Rate (minutes /inch) Number of Bedrooms (or other) 4 Re.o4ie o r nrP.v7 - o- af//.'- sys7t-111 Required Absorption Area - See Attached Special Setback Requirements: Date Inspector FINAL SYSTEM INSPECTION AND APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering Installation System Installer DRAEGER EycAPIA Septic Tank Capacity /SOO GALLON "&lPFLej Septic Tank Manufacturer or Trade Name /.-YL Septic Tank Access within 8" of surface Vt5 AbsorptiewAfee Ca4O,7r UC»D 5 .1 01 e# 0 7 /u eti6 `ir rn Absorption Area Type and /or Manufacturer or Trade Name ET 7)9.e Sea Adequate compliance with County and State regulations /requirementsteLS Other OK ro cart, se - e TANK .. - f9 - !/ 47/flr Date 3 `13 96 Inspector RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE *CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con- nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs, alters, or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 flne — 8 months in jail or both). white Yellow - DEPARTMENT IN 1)1 VII)LIA1..Sf WAG Ii .l)1SPOSA1._SYSTEMI\PPLICATION OWNER faro K . vv) L ADDRIiss s3 7o iQd. IdQ PII 3c3 94j ze_e‘ CONTRACTOR _ AI)I)RI:SS — PHONE PER MI'I' ItEQUI:ST FOR ( ) NEW INSTALLATION (r/f ALTERATION ( ) REPAIR Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable building, location of potable wafer wells, soil percolation lest boles, soil profiles in test holes (See page 4). LQCAI DI? PROPOSED FACILITY.: COI NTY t y� r rte/ Nenr what Cily or Town /✓W c _ .(kt..-4 - r __ L n1 Legal I)cscriplion ! ( ) 'Transient U WAS "I'IiS'fl'I'1: M Dwcllin; ( ) Commercial or Industrial ( ) Non - domestic Wastes ( ) Other - 1)escrihe --- 1111I 1.1)1 NG OR Stilt V ICIi TYPE:-7,0 -JJ ---- - - - - -- -- - - - - -- Number of bedrooms: __— --------- _-- _.--- _-- . -__ - -- Number of persons 7_ ti ( ) Garbage Grinder (✓) Automatic Washer (✓) Dishwasher SOURCIi-AND "LYPL' OF_WAflR SLIPI-'I.Y: (✓) WELL ( ) SPRING ( ) STREAM OR CREEK Give depth of all wells within 1811 feet ol' system: � _ ',tiQ i If supplied by community wafer, give name of supplier °____ -_-- GROUND CONh_1TIQNS: Depth lo bedock: G.itt>fya b ) Depth to first Ground Water Table: — Percent Grdiu Slope: -- _----- .. --c - >� __. -- ---- _ - -- -- I) 1S' I' ANCR' I'O NEAREST COMMIJNI'I'1' SHAVER SYSTEM: - '- ,, e Was an effort made to connect to community system? 4- -- -- TYPl OE INDIVIDl IAI. SEWAGI? DISPOSAL SYS'I'NNM PROPOSED: (v5 Septic Tank ( ) Aeration Plant ( ) Vault ( ) Vault Privy ( ) Composting "Toilet ( ) Recycling, potable use ( ) Pit Privy ( ) Incineration Toilet ( ) Recycling, other use ( ) Chemical toilet ( ) Other - Describe: FINAI. I)ISPOSAI. BY: — ( ) Absorption "french, Bed or Pit Yw Evapotranspiration ( ) Underground Dispersal ( ) Sand Filler () Above Ground Dispersal ( ) Wastewater Pond ( ) Other - Describe: _ WII.1. FEN.111'NN'I'RIS DISCI !ARCM) 1)IRI:CI'LY INTO\VA'I'I?RS 0u'TPIE STATI?'? Na I'ILICQI4Ai'InN_ IST% RGSL1..I . (To he completed by Registera Engineer) Minutes - per inch in hole No. I Minutes __ per inch in Hole No. 3 Minutes per inch in hole No. 2 Minutes per inch in Hole No. Name, addres and telephone of RN: who made soil absorption tests: Name, address and telephone of Itl?I( responsible for design of the system: Applicant acknowledges That the completeness oflheappliclion is conditional upon such further mandatory and additional rests and reports as may be required by Ilse local health department lo he made and furnished by the applicant or by the local health department for purposes of the evaluation of the application; and the issuance of the permit is subject to such terms and conditions as deemed necessary to inusre compliance with rules and regulations adopted under Article It), Title 25, C.R.S. 1973, as amended. The undersigned hereby certifies that all statements make, information and reports submitted herewith and required to be submitted by the applicant are or will he represented to be true and correct to the hest of my knowledge and belief and are designed to bre relied on by the local department of health in evluating the same fro purposes of issuing Ilse permit applied for herein. 1 further understand that any falsification or misrepresentation may result in the denial of the application or revocation ol' any permit granted based upon said application and in legal action Iitr perjury as provided by law. Signed _ _� Q- % se�S7i I)ale / //f /96 CLEASIi I_ ACC!!RATIi NIA l'.T0._YO11R-1'R41'ER"l_'Y /f ;3 Ok ref. I ` J aU G` / C�� Yc3 S. I Gfl A, t-. , -.2 e ���� br_d u/ 1 F. R Filzgcrnld, F'.F.. • 10144 E. Jewell Avc, H2 Denver, Cola 80211 1 . } d F P Fi tzgeral j � ' :F , :. Mnf -O 0 1996 'S1 U,11 4'1C .I_U C- CX.11f Y March 6, 1996 Mr. Jake Jacobsen Garfield Co. Bldg. Insp. 109 8 Street, Suite 303 Glenwood Springs, Colo. 81601 Dear Mr. Jacobsen: This leper concerns the Jack Snobble properly near Carbondale. On Nov 25, 1995, I inspected the constructed wetland system being used at the Snobble house to treat household wastewater. I collected water samples from various points in the system, and in the surrounding drainage, stored these samples under standard conditions, and delivered them to the laboratory of the Colorado Department of Public Health and Environment in Den ver. 'rho samples were analyzed for fecal coliforms. Results were reported to Mr Snobble earlier. "his letter is to } chtri(y the Significance of those reported numbers, as a measure of the effectiveness of the treatment System. p , the ttektructed wetland is within the surface and subsurface drainage path of natural wetlands on t.'' the 5 ilbhble Property, and the natural wetlands extend both upstream and downstream from the constructed system. Considering both the constructed and natural wetlands, as far as the point where thetiatural drainage channel leaves the Snobble property, to be an integrated treatment system, it is 'seen that the water quality al the property line exceeds the Colorado slate standards for both Class 1 Odium human contact and for cold water fish spawning. Dissolved oxygen and pI I were nreasul ec! in place with a Corning M -90 portable instrument . Measurement Class I Standard Cold Water Life Standard D. 0., mg/1 8.5 3.0 or greater 7.0 or greater pll 8.27 6.5 to 9.0 6.5 to 9.0 Fecal Coliforms 8 200 or less not specified Should there be any need for further discussion or clarification, please do not hesitate to write or call me directly at 303- 755 -4374 Sincerely, F. Patrick Fitzgerald Colorado Registered PE number 19656 F. P. Fitzgerald, P.E • o , 10144 E. Jewell Ave, #2 Denver, Colo. 80231 { ..- - 1 Cr >. 7 T -1 — 3 w r - - � s . r q, r leig J li i A e4s `' .ss a ,: j . x r '" ... y„� 1 � t; .a� �fi r' a kr s .�' E t? ° .... urnr- .r..ir.. LD C:CXM'UY March 6, 1996 Mr. Jake Jacobsen Garfield Co. Bldg. Insp. 109 8 Street, Suite 303 Glenwood Springs, Colo. 81601 Dear Mr. Jacobsen: This letter concerns the Jack Snobble property near Carbondale. On Nov 25, 1995, I inspected the constructed wetland system being used at the Snobble house to r ,.,..,treat household wastewater. I collected water samples from various points in the system, and in the surrounding drainage, stored these samples under standard conditions, and delivered them to the '- ,.laboratory of the Colorado Department of Public Health and Environment in Denver. The samples were analyzed for fecal coliforms. Results were reported to Mr Snobble earlier. This letter is to elarify1the'Bigniftcance of those reported numbers, as a measure of the effectiveness of the treatment system '; The egnstructed wetland is within the surface and subsurface drainage path of natural wetlands on '.the Sriribble property, and the natural wetlands extend both upstream and downstream front the ' eontructed system. Considering both the constructed and natural wetlands, as far as the point where 'the: nat drainage channel leaves the Snobble property, to be an integrated treatment system, it is Seen thaf the water quality at the property line exceeds the Colorado state standards for both Class I ,primary human contact and for cold water fish spawning. Dissolved oxygen and pH were measured in place with a Corning M -90 portable instrument . Measurement Class I Standard Cold Water Life Standard D. 0., mg /1 8.5 3.0 or greater 7.0 or greater pH 8.27 6.5 to 9.0 6.5 to 9.0 Fecal Coliforms 8 200 or less not specified Should there be any need for further discussion or clarification, please do not hesitate to write or call me directly at 303 - 755 -4374 Sincerely, 6(1 F. Patrick Fitzgerald Colorado Registered PE number 19656