HomeMy WebLinkAbout02558 ^r
LEACH FIELD "B"
GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT Permit 2 i 8
109 8th Street Suite 303 Assessor's Pa el No.
Glenwood Springs, Colorado 81801
4 j Phone (303) 945 -8212
This does not constitute
\ INDIVIDUAL SEWAGE DISPOSAL PERMIT a building or use permit.
PROPERTY
Owner's Name Sopris RV Park Present Address 0640 County .Road 106. Carbtione 963-0163
System Location 0640 County Road 106, Carbondale
Legal Description of Assessor's Parcel No.
SYSTEM DESIGN
Septic Tank Capacity (gallon) Other
Percolation Rate (minutes/inch) Number of Bedrooms (or other) SEE LETTER FROM ENARTECH
let Pete Zerrv4 - /JO Chytt ' OZ / /Fa *77o'll5
Required Absorption Area - See Attached 7Y5 ther-icfeLs
Special Setback Requirements:
Date Inspector �y �'
FINAL SYSTEM INSPECTION AND APPROVAL (as installed) NoTE — See. /545 ik.e/son -' - " "/
Call for Inspection (24 hours notice) Before Covering Installation
Sys • staller
Septic Tank Capacity
Septic Tank Manufacturer or Trade ` ..le
Septic Tank Access within 8" of surface
Absorption Area 9A _
Absorption Area Type and /or , facturer or Trade Jame a - yl �_ I i✓'ti 7g.4rers
Adequate compile ; = with County and State regul ations/requirements 165
` Other -( d
late 1 L - J - � Inspector _ —
RETAIN 'WITH RECEIPT RECORDS AT CRUCTION SITE
*CONDITIONS:
1. All Installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter
25, Article 10 C.R.S. 1973, Revised 1984.
2. This permit Is valid only for connection to structures which have fully complied with County zoning and building requirements. Con-
nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a
requirement of the permit and cause for both legal action and revocation of the permit.
3. Any person who constructs, alters, or installs an individual sewage disposal system in a manner which involves a knowing and material
variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine — 6
months in )ail or both).
While - APPLICANT Yellow • DEPARTMENT
ENARTECH Inc. Consulting Engineers and Hydrologists
December 21, 1994
Mr. Mark Bean
Garfield County
109 Eighth Street, Suite 303 ®®®a
Glenwood Springs, CO 81601
RE: Sopris RV Park
Dear Mark:
Enclosed are Individual Sewage Disposal System permit applications for the Sopris
RV Park Leach Fields A and B. The design flow for each leach field is based upon
actual flows measured at the Sopris RV Park from October 25 to November 22,
1994. The total average daily flow measured was 2,132 gallons per day (gpd). The
total design flow for the two leach fields is 4,238 gpd as outlined in the enclosed
design calculations.
Leach Field A is a proposed leach field to be located near the entrance at the west
end of the Sopris RV Park. This leach field will replace the existing leach field
located adjacent to the Manager's residence. The existing septic tanks and dosing
tanks for this system will be utilized. This system will serve RV Spaces 1 - 21 and
the Manager's Residence; up to 4 bedrooms were allowed in the Manager's
Residence to allow for future expansion of this residence. The average flow into
this system at full occupancy is estimated to be 1,475 gpd; the design flow is 2,213
gpd. The proposed leach field consists of 62 "Biodiffuser" leach field chambers as
shown on the enclosed design drawing and specifications. The required setbacks
include 147 feet from the irrigation ditch, 197 feet from the water supply well and
379 feet from Leach Field 13.
Leach Field I3 is an existing sewage disposal system located at the east end of the
Sopris RV Park. This leach field serves RV Spaces 22 - 27, the laundry and the
shower facilities. The average flow into this system at full occupancy is estimated to
be 1,350 gpd; the design flow is 2,025 gpd. The existing system consists of two septic
tanks and a 2,400 square foot leach field. The required size for this leach field is
1,400 square feet. The required setbacks include 132 feet from the irrigation ditch,
182 feet from the water supply well and 379 feet from Leach Field A. The existing
septic tanks and leach field are sufficient as constructed; no improvements to the
existing Leach Field B system are proposed.
302 Eighth Street, Suite 325 P.O. Drawer 160 Glenwood Springs, Colorado 81602 (303) 945-2236
Mr. Mark Bean
Page - 2
Both leach field systems meet the required setbacks from the irrigation ditch and
from the water supply well. The two leach field systems also meet the State's
separation requirements to be considered individual systems under the County's
jurisdiction. Construction of Leach Field A will commence upon issuance of the
ISDS Permit. Please give me a call is you have any questions or require additional
information.
Sincerely,
ENARTECH, INC.
S — 7 , - IA
Peter Belau, P.F.
PB /jlw
Enclosure
cc: Sopris RV Park
1'407 -01 (P407_0211)94
:-.e. a-..
3
. T _ , - •
j r
INDIVIDIJAT. SEWAGE DISPOSAL SYSTEM APPLICATION
OWNER Sopris RU Park Leach Field "B"
ADDRESS 0640 County Road 106 PHONE 963 -0163
CONTRACTOR
ADDRESS PHONE
PERMIT REQUEST FOR ( X) NEW INSTALLATION () ALTERATION () REPAIR
Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area,
habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes
(See page 4).
J .00ATION OF PROPOSED FACILITY COUNTY Garfield
Near what City or Town Carbondale Lot
Legal Description NW /4. SE /4. Section 28. T.79., R.B8I0I.
WASTES TYPE: ( ) Dwelling ( ) Transient Use
( ) Commercial or Industrial ( ) Non - domestic Wastes
(X) Other- Describe RV Park - 6 Spaces; Shower and Laundry Facilities
BUILDING OR SERVICE TYPE: Manager's Residence ano 21 RV Spaces
Number of bedrooms: Number of persons
( ) Garbage Grinder (X) Automatic Washer ( ) Dishwasher
SOT MCP AND TYPE OF WATER SIJPPI,Y: (x) WELL () SPRING ( ) STREAM OR CREEK
Give depth of all wells within 180 feet of system: Nune
If supplied by communtiy water, give name of supplier:
IOROTJNT) CONDITIONS:
Depth to bedrock: more tnan 20 feet
Depth to rust Ground Water Table: more than 20 feet
Percent Ground Slope: 1 percent
DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: 700 ft. across river
Was an effort made to connect to community system? yes; tuo expensive
TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED:
(x) Septic Tank ( ) Aeration Plant ( ) Vault
( ) Vault Privy ( ) Composting Toilet ( ) Recycling, potable use
( ) Pit Privy ( ) Incineration Toilet ( ) Recycling, other use
( ) Chemical Toilet ( ) Other - Describe:
FINAL DISPOSAL BY:
(x) Absorption Trench, Bed or Pit ( ) Evapotranspiration
( ) Underground Dispersal ( ) Sand Filter
( ) Above Ground Dispersal ( ) Wastewater Pond
( ) Other - Describe:
WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? No
pERCOT.ATION TEST RESULTS: (To be completed by Registered Professional Engineer)
Minutes 5 per inch in hole No. 1 Minutes 23 per inch in Hole No. 3
Minutes 6 per inch in hole No. 2 Minutes per inch in Hole No.
Name, address and telephone of RPE who made soil absorption tests: Peter Belau, P.E.
Enartech, Inc., P.O. Drawer 160, Glenwood Springs, CO 81602, 945 -2236
Name, address and telephone of RPE responsible for design of the system: same
Applicant acknowledges that the completeness of the appliction is conditional upon such further mandatory
and additional tests and reports as may be required by the local health department to be made and furnished
by the applicant or by the local health department for purposes of the evaluation of the application; and the
issuance of the permit is subject to such terms and conditions as deemed necessary to inusre compliance with
rules and regulations adopted under Article 10, Title 25, C.R.S. 1973, as amended. The undersigned hereby
certifies that all statements make, information and reports submitted herewith and required to be submitted
by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and
are designed to bre relied on by the local department of health in evluating the same fro purposes of issuing
the permit applied for herein. I further understand that any falsification or misrepresentation may result in •
the denial of the application or revocation of any permit granted based upon said application and in legal
action for perjury as provided by law.
Signed ( c ) :— ::'--- 2 " 5 ""^- Date (a — a i — 9 4 /
Peter Belau, P.E., Design Engineer
PLEASE DRAW AN ACC! IRATE MAP TO YOIJR PROPERTY
•
•
4. , w
p1 OT In AN AND DFSIGN FFATT JRF.S
Include by measured distance location of wells, springs, potable water supply lines, cisterns, buildings,
property lines, subsoil drains, lake, water course, stream, dry gulch and show location of proposed system by
direction and distance from dwelling or other fixed reference object, and additional submissions in support
of this application such as data, plans, specifications statements and commitments.
See Attached Drawing