GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT Permit 2958
. . 109 8th Street Suite 303 Assessor's Parcel No.
Glenwood Springs, Colorado 81601
Phone (303) 945 -8212
This does not constitute
INDIVIDUAL SEWAGE DISPOSAL PERMIT a building or use permit.
PROPERTY II `' l
Owner's Name a u ' 'k ` CA- f °`�' ' IL4 Present Address 1 R� kc c c In - CY , Phone 9 - 0 ( oi rj
System Location Cd r ] q (non 0 . l . C o r V,on ( G 9 C c7
Legal Description of Assessor's Parcel No. (� �� O" /O
,) tk d K -LEACH - F - ----^T 12 39
SYSTEM DESIGN a) 4- ACM CHAMaC4 - g350 = 4O UN ITS- -s r 7y 1 '
3) I1 11 '� a ENCHES : 3a '• k ur 604
O Septic Tank Capacity (gallon) Other p 2-I ltr CL
0 Percolation Rate (minutes /inch) Number of Bedrooms (or other)
3
/ 4(1 m.
Required Absorption Area - See Attached Pert H
is ID rT
Special Setback Requjremen
Date ■ O- Inspector A R rt 0
FINAL SYSTEM INSPECTION AND APPROVAL (as installed)
Call for Inspection (24 hours notice) Before Covering Installation I
System Installer 1 v
1 e) � 0 Y& A is e)J( ` Q A v r
1
Septic Tank Capacity 2 X
Septic Tank Manufacturer or Trade Name C' O pit A “ '/ /�
`/
Septic Tank Access within 8•• of surface T /�
Absorption Are ) (I � � ` I O U / I \ ' t � A � + CO C
Absorption Area Type and /or Manufacturer or Trade Name 1 Fit t T ` A. A T 0 S
Adequate compliance with County and State regulations/requirements Y C S
Other 4 9 A
Date 1 - t > -9 O Inspector A '` N D
RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE
*CONDITIONS:
1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter
25, Article 10 C.R.S. 1973, Revised 1984.
2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con-
nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a
requirement of the permit and cause for both legal action and revocation of the permit.
3. Any person who constructs, alters, or installs an individual sewage disposal system in a manner which involves a knowing and material
variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine — 6
months in )ail or both). '
White - APPLICANT Yellow - DEPARTMENT
INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION
OWNER 3r'uc.t La..sa.r'c.. Wt kU nsOtn►
ADDRESS 191 S4at `/ 'M tv • PHONE q cO '3 ' (Yarn CONTRACTOR IT1itCA Crete (On' ruc - 1'tc'
ADDRESS WSI tit fl-4 C le PHONE %3' Si
PERMIT REQUEST FOR (.NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area,
habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4).
J,OCATION OF PROPOSED FACILITY:
Near what City of Town e G r bcr+& amp Size of Lot Q • 37 cC •
Legal Description or Address b VY\oncOnct n Or . 1 Ca.riormA CO
WASTES TYPE: (tWELLING ( ) TRANSIENT USE
( ) COMMERCIAL OR INDUSTRIAL ( ) NON - DOMESTIC WASTES
( ) OTHER - DESCRIBE
BUILDING OR SERVICE TYPE:
Number of Bedrooms Number of Persons
( ) Garbage Grinder ( ) Automatic Washer ( ) Dishwasher
SOTTRT : AND TYPE OF WATER SIJPPJ.Y: ( _� r ( ) SPRING ( ) STREAM OR CREEK
If supplied by Community Water, give name of supplier:
DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM:
Was an effort made to connect to the Community System?
•
• • 1,1 •1 • I i •• 1 u� i i i it • l • 1 1. u \ td u
Leach Field to Well: 100 feet
Septic Tank to Well: 50 feet
Leach Field to Irrigation Ditches, Stream or Water Course: 50 feet
Septic System to Property Lines: 10 feet
YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WIT,i, NOT BE ISSUED
WITHOUT A SITE PT.AN.
GROI ND CONDITIONS:
Depth to first Ground Water Table
Percent Ground Slope
2
•
•
' •TYPE' INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED:
(PTIC TANK ( ) AERATION PLANT ( ) VAULT
( ) VAULT PRIVY ( ) COMPOSTING TOILET ( ) RECYCLING, POTABLE USE
( ) PIT PRIVY ( ) INCINERATION TOILET ( ) RECYCLING, OTHER USE
( ) CHEMICAL TOILET ( ) OTHER - DESCRIBE
FINAL»ISPOSAL BY:
( ) ABSORPTION TRENCH, BED OR PIT ( ) EVAPOTRANSPIRATION
( ) UNDERGROUND DISPERSAL ( ) SAND FILTER
( ) ABOVE GROUND DISPERSAL ( ) WASTEWATER POND
( ) OTHER - DESCRIBE
WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE?
?ERCOT ,ATION TEST RF.S1 II TS (To be completed by Registered Professional Engineer, if the Engineer does
the Percolation Test)
Minutes per inch in hole No. 1 Minutes per inch in hole NO. 3
Minutes per inch in hole No. 2 Minutes per inch in hole NO. _
Name, address and telephone of RPE who made soil absorption tests:
Name, address and telephone of RPE responsible for design of the system:
Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and
additional tests and reports as may be required by the local health department to be made and furnished by the
applicant or by the local health department for purposed of the evaluation of the application; and the issuance of the
permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations
made, information and reports submitted herewith and required to be submitted by the applicant are or will be
represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the
local department of health in evaluating the same for purposes of issuing the permit applied for herein. I further
understand that any falsification or misrepresentation may result in the denial of the application or revocation of any
permit granted based upon said application and in legal action for perjury as provided by law.
Signed Date
PLEASE DRAW AN ACCURATE MAP TO YOUR PROPERTY!!
3
Fab - 10 -98 01:55P PRINCE CREEK 970 963 2140 P.02
4
HEPWORTH- PAWLAK GEOTECHNICAL, INC. 5020 Road 154
Glenwood Springs, CO 81601
Fax 970 9954454
September 22, 1997 Phone 970945-7988
Bruce Wilkinson
P.O. Box 268
Carbondale, Colorado 81623 Job No. 197 496
Subject: Subsoil Study for Foundation Design and Percolation Test, Proposed
Residence, Lot 5, Up Cattle Creek Subdivision, Garfield County,
Colorado
Dear Mr. Wilkinson:
As requested, Hepworth- Pawlak Geotechnical, Inc. performed a subsoil study and
percolation test for foundation and septic disposal designs at the subject site The study
was conducted in accordance with our agreement for geotechnical engineering services
to you dated August 12, 1997. The data obtained and our recommendations based on
the proposed construction and subsurface conditions encountered are presented in this
report.
Proposed Construction: The proposed residence will be a two story wood frame
structure with an attached garage located on the site as shown on Fig. 1. Ground and
garage floors are proposed to be slab -on- grade. Cut depths are expected to up to about
6 feet. Foundation loadings for this type of construction are assumed to be relatively
Tight and typical of the proposed type of construction. The septic disposal system is
proposed to be located about 20 feet east of the proposed residence.
If building conditions or foundation loadings are significantly different from those
described above, we should be notified to re- evaluate the recommendations presented in
this report.
Site Conditions: The site was vacant at the time of our field work. The building site
is located on top of a relatively flat area with slopes down in all directions. The ground
surface in the area of the proposed residence and leach field is gently rolling with slight
w moderate slopes. There is about 8 feet of elevation difference in the building area.
The lot is steeply sloping to the north of the proposed leach field. The lot is vegetated
with sagebrush, grass, weeds and scattered juniper and pinon trees. Basalt cobbles and
boulders up to 4 feet in diameter are located on the ground surface.
Subsurface Conditions: The subsurface conditions at the site were evaluated by
excavating one exploratory pit in the building arca and one profile pit in the septic
disposal area at the approximate locations shown on Fig. 1. Pit I was an existing pit
for a reported septic tank location that was widened and cleaned out. The logs of the
pits are presented on Fig. 2. The subsoils encountered, below about I to 11/2 feet of
topsoil, consist of basalt gravel, cobbles and boulders in a sandy silt matrix. Results of
a gradation analysis performed on a sample of the gravels (minus S inch fraction)
Fab -10 -98 01:55P PRINCE CREEK 970 963 2140 P.03
• a
Bruce Wilkinson
September 22, 1997
Page 2
obtained from the site are presented on Fig. 3. No free water was observed in the pits
at the time of excavation and the soils were slightly moist to moist.
Foundation Recommendations: Considering the subsoil conditions encountered in the
exploratory pits and the nature of the proposed construction, we recommend spread
footings placed on the undisturbed natural soil designed for an allowable soil bearing
pressure of 2,000 psf for support of the proposed residence. Footings should be a
minimum width of 16 inches for continuous walls and 2 feet for columns. Loose and
disturbed soils encountered at the foundation bearing level within the excavation should
be removed and the footing bearing level extended down to the undisturbed natural
soils. Voids created by the removal of boulders should be backfilled with road base or
concrete. Exterior footings should be provided with adequate cover above their bearing
elevations for frost protection. Placement of footings at least 36 inches below the
exterior grade is typically used in this area. Continuous foundation walls should be
reinforced top and bottom to span local anomalies such as by assuming an unsupported
length of at least 10 feet. Foundation walls acting as retaining structures should be
designed to resist a lateral earth pressure based on an equivalent fluid unit weight of at
least 45 pcf for the on -site soil, exclusive of topsoil and oversized rock, as backfill.
Floor Slabs: The natural on -site soils, exclusive of topsoil, are suitable to support
lightly loaded slab -on -grade construction. To reduce the effects of some differential
movement, floor slabs should be separated from all bearing walls and columns with
expansion joints which allow unrestrained vertical movement. Floor slab control joints
should be used to reduce damage due to shrinkage cracking. The requirements for joint
spacing and slab reinforcement should be established by the designer based on
experience and the intended slab use. A minimum 4 inch layer of free- draining gravel
should be placed beneath slabs -on -grade to facilitate drainage and act as a leveling
course. This material should consist of minus 2 inch aggregate with less than 50%
passing the No. 4 sieve and less than 2% passing the No. 200 sieve.
All fill materials for support of floor slabs should be compacted to at least 95% of
maximum standard Proctor density at a moisture content near optimum. Required fill
can consist of the on -site soils devoid of vegetation, topsoil and oversized rock.
Surface Drainage: The following drainage precautions should be observed during
construction and maintained at all times after the residence has been completed:
1) Inundation of the foundation excavations and underslab areas should be
avoided during construction.
2) Exterior backfill should be adjusted to near optimum moisture and
compacted to at least 95% of the maximum standard Proctor density in
pavement and slab areas and to at least 90% of the maximum standard
H -P GEOTECM
Fab -10 -98 01:56P PRINCE CREEK 970 963 2140 P.04
•
Bruce Wilkinson
September 22, 1997
Page 3
Proctor density in landscape areas.
3) The ground surface surrounding the exterior of the building should be
sloped to drain away from the foundation in all directions. We
recommend a minimum slope of 12 inches in the first 10 feet in unpaved
areas and a minimum slope of 3 inches in the first 10 feet in pavement
and walkway areas.
4) Roof downspouts and drains should discharge well beyond the limits of
all backfill.
Percolation Testing: Percolation tests were conducted on August 22, 1997 to evaluate
the feasibility of an infiltration septic disposal system at the site. One profile pit and
three percolation holes were dug at the locations shown on Fig. 1. The test holes
(nominal 12 inch diameter by 12 inch deep) were hand dug at the bottom of shallow
backhoe pits and were soaked with water one day prior to testing. The soils exposed in
the percolation holes are similar to those exposed in the Profile Pit shown on Fig. 2 and
consist of 1 foot of topsoil overlying basalt gravel, cobbles and boulders in a sandy silt
matrix to the refusal depth of 3' feet. The percolation test results are presented in
Table I. The percolation test results indicate an infiltration rate of 30 minutes per inch.
The percolation rate was based on the last 2 readings of the test. Based on the
subsurface conditions encountered and the percolation test results, the tested area
should be suitable for a conventional infiltration septic disposal system.
Limitations: This study has been conducted In accordance with generally accepted
geotechnical engineering principles and practices in this area at this time. We make no
warranty either expressed or implied. The conclusions and recommendations submitted
in this report are based upon the data obtained from the exploratory pits excavated at
the locations indicated on Fig. 1, the proposed type of construction and our experience
in the area. Our findings include interpolation and extrapolation of the subsurface
conditions identified at the exploratory pits and variations in the subsurface conditions
may not become evident until excavation is performed. If conditions encountered
during construction appear different from those described in this report, we should be
notified at once so re- evaluation of the recommendations may be made.
This report has been prepared for the exclusive use by our client for design purposes.
We are not responsible for technical interpretations by others of our information. As
the project evolves, we should provide continued consultation and field services during
construction to review and monitor the implementation of our recommendations, and to
verify that the recommendations have been appropriately interpreted. Significant
design changes may require additional analysis or modifications to the
recommendations presented herein. We recommend on -site observation of excavations
H -P GEOTECN
Feb -10 -98 01:66P PRINCE CREEK 970 963 2140 P.05
Bruce Wilkinson
September 22, 1997
Page 4
and foundation bearing strata and testing of structural fill by a representative of the
geotechnical engineer.
If you have any questions or if we may be of further assistance, please let us know.
Sincerely,
HEPW H - PAWLAK GEOTECH AL., INC.
-�, p9pp,REG/s7�
(r .. to.
S cZ . i� ' 0 j1 ,...
, • 1. Jordy Z. dam n,Jr. P.E. i 29707 pj i
Reviewed By: ‘' 'ONA1. E� =
Daniel E. Hardin, P.E.
.JZA /kw
attachments
cc: Kurtz & Associates - Mtn: Brian Kurtz
H•P MOTECH
Fab - 1O -98 01:66P PRINCE CREEK 970 963 2140 P.06
P 2
APPROXIMATE SCALE
■ 10'
P 1
PROFILE PIT
•
P 3
A
1
•
PIT 1
PROPOSED RESIDENCE
(BUILDING CORNERS STAKED)
197 496 I GEOTECHNICAL. INC. I AND APERCOLATION EXPLORATORY
TEST HOLES l Fig. 1
•