HomeMy WebLinkAbout03531 a ,
System shall be installed in accordance with all applicable Garfield County Building and Sanitation
Dept. and manufactures specifications.
Sincerely,
Gambia & Associates, Inc.
6 1 49 24
Chris Strouse, Desig ' er
r
E
Robert 7.
W. Penning t
1 •
GARFIELD COUNTY
ISDS DESIGN CALCULATIONS
Owner's Name IMMIMMINIMMIMParcel ID # Milannalatini
House Size (sq. ft.) 900 54
Number of Bedrooms in Main House
Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House
Number of Bedrooms in Detached Caretaker unit
Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit
(If the caretaker unit is ATTACHED, treat as if part of main house.)
Average Daily Waste Flow : 108
State Review Required ?: no
Perc Rate (t)
Design Flow (Q) _ # potential bedrooms X 2 people /bedroom X gpd X 1.50
Q- 162
Absorption Area
A = S x�
A = 224.47 sq. ft. of absorption area required
15 infiltrator units without reduction
A maximum 50% reduction Is allowed for use of deep gravel or gravelless chambered system,
only if the lot size and soil conditions are optimal.
If a reduction is being proposed, describe why lot size and soil conditions are optimal:
We will use a 40% reduction in Trench area because of the Percolation Test results.
A = 157.13 sq.ft. with reduction
11 infiltrator units with reduction
Type of system: [X]Absorption trenches ()Absorption bed D Gravelless chambers
DDry well ()Seepage Pit ['Other (type)
SETBACK FROM WELL
# of feet - 100
SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet = 50
SETBACK FROM DRY GULCH
# of feet = 25
FINAL INSPECTION BY: DATE: