Loading...
HomeMy WebLinkAbout4249 ..., . +r .. a..,... — ^;wwm'm!!1plverr5' • .wr ...... ... .. - n 04249 GARFIELD COUNTY BUILDING, SANITATION and PLANNING DEPARTMENT 109 8th Street Suite 303 Glenwood Springs, Colorado 81601 (303) 946 -8212 Job Address 110 Nature of Work Y,iriidinz Perinit Use of Building Construction Steal Building for Storage owner Rocky Gaboani Contractor owner Amount of Permit: $ 252.45 Date: June 17, 1991 Permit $153.00 plan ti 99.45 R. Bennett Clerk White- Trees Canary - Office Pink - Applicant Gold - Duplicate GARFIELD COUNTY a ./ r APPLICATION FOR BUILDING PERMIT Q PERMIT NUMBER r please print or type DATE ‘, - S- `l 1 e A S S e C O r S Prcef # z'3f3 ,74- oo ooC TO BE FILLED OUT BY APPLICANT PLOT PLAN ADDRESS cos, an NOTE: Show easements, property line dimensions, SUBDIVISION all other structures, specify north, andstreet m FILING # LOT H /y j S BLOCK # name. For odd shaped lots, or if space is w TAX SCHEDULE 4 G / too small, provide separate plot plan. LEGAL (SEC /TWN /RNG) Lo{. t - 0 # OF BUILDINGS NOW ON PARCEL 11I6 • NAME (] } � , �,, USE OF BUILDINGS NOW ON PARCEL W .MAILING ADDRFS.' II a t s - Pw1 „Pr [2(04,...„ p C TPY CI e 1.‘ ..,..)co r�4..;� ts& PIIONE 99 St 73 r y a NAME a ADDRESS CITY a w ,r - - -- --41- m NAME o G 0..1n o S s S. g ADDRESS . ,.,.. r , ; N.,‘ c . Q.,. g CITY Glgn w 0 o et Gr l D.. N o I P HONE lets - _ 76? 1 LICENSE' # n CLASS OF WORK � S SC+f - NEW L--- ALTERATION ADD.TTION ° DEMOLISH REPAIR MOVE MOBILE HOME (make /model) ' OF BUILDING Qi S.F. OF LOT 4 OF FLOORS HEIGHT #1.010 , # OF FAMILY UNITS 4 OF BEDROOMS :INTENDED USE OF BUILDING. •1, GARAGE: SINGLE DEL CARPORT: NGr,E DBL _ _ FRONT PROPERTY LINE LFIREPLACE Q � DOCUMENTS ATTACKED _ STREET NAME /ROAD NUMBER a Rd 11 n /V ^ WATER SUPPLY ["C CHECK IF CORNER LOT DRIVEWAY PERMIT � Qr u: MSS. DESCRIPTION OF WORK PLANNED Q } yuc.� SITE PLAN t/ am, ktm I ac {r.rsrk :Skeek Ncdr. BUILDING PLANS t, ^ SANITARY SEWER CLEARANCE NR I ereby acknowl dge that I have read this ON SITE SEWAGE DISPOSAL PERMIT Ar 1 application and the above is correct and I OTHER DOCUMENTS (specify) ro„4, &cL.* ., agree to comply with all county ordinances f ecS:•. - rC;2# 7,:1 e_.F• chP'L5 n and state laws regulating building construction. / / � _ hi•cAr -ez- • _ SIGNAATU FOR OFFICE USE ONLY VALUATION DUD. 0 0 FLOOD HAZARD PERMIT FEE $ 0 L CHECK FF. P•. $ 99 4. 7' CERTIFIED BLDG ELEVATION TOTAL FEE $ 1 Z , ¢C SCHOOL IMPACT FEE $ / 4-- SPECIAL CONDITIONS ALL Oast, ,A4-Alt limm*r-i-gmasig DATE PERMIT ISSUED Tkmp , 10 4etnop --1 3.07. Of . t ZONING DISTRICT CA PROBLEMS WITH PERMIT c vaem., AS TYPE OF OCCUPANCY ! Sr, 4 y .i S' ' • ' — 161 S P t - GZ '+4[L,- plasm Prapivv,F4) , TYPE OF CONSTRUCTION - ADDITIONAL INFORMATION NEEDED S.F. OF BUILDING S.F. OF LOT t- Q C, 1 MAX. HEIGHT ---,---/ S ROAD CLASS. m CERTIFIED BY COLORADO REGISTERED LAND SURVEYOR SETBACKS FROM PROPERTY LINE: FRONT /4-40/4_ OR ENGINEER •„• REAR RIGHT LEFT OFF STREET PARKING SPACES REQUIRED 5 E'E . Z c 4 APPROVED: Alta �,/��,/ a 3 APPROVE � a . _y �� ;C rin �eU ILDING DEPAR MEN d e , D TE PLANNING DEPART' N O f DATE L. i i iii/e0e6C' y' C; �j 3 G? ssi CV14/9/ i; r a,/ c./ l C) 4 a 7l� 0 ' � cz Z 3 a ,0?, f CJ. J J • J c 1 S f 5.4 C. / r C.5 v7 f<.-f , ` r, , _ •' . . f cL,1 c_ L'..) n '' � , u d c , v j rl ZU I I r ii 1! ' il 1 I i i II ' at i ii II ii I I il Iii ;;I i ii 1 i . • . PERMIT / OWNEII ((,« Y 6/1105,5 C.t'2 / LOCATION eC/ , • CONTRA TOR__,,., r 1 TIIE FOLLOWING ITEMS MAY HAVE BEEN OMITTED FROM YOUR PLANS OR MAY NOT COMPLY WITH TIIE PROVISIONS OF THE UNIFORM BUILDING CODES. PLEASE CHECK ALL CIRCLED ITEMS BEFORE BEGINNING CONSTRUCTION. ALL REFERENCES ARK 1900 EDITIONS OF THE CODES. THESE ITEMS ARK- .REQUIREMENTS• FOR R -3-' OCCUPANCIES ONLY (ONE' AND-THO•FAMILY DWELLINGS)""AND ARE NOV ALL INCLUSIVE OF Tllli CODE REQUIREMENTS, BUT ARE MEANT AS ) A GUIDE TO SOME OF TIIE 14051' OFTEN ENCOUNTERED QUESTIONS RELATED TO CODE REQUIREMENTS. THE APPROVED PLANS RETURNED TO YOU SHALT, DE KEPT AT TIIE BUILDING SITE DURING CONSTRUCTION. FOR ANY REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE CONTACT THE COLORADO ELECTRICAL INSPECTOR. THERE SHALL, BE A FINAL INSPECTION AND APPROVAL OF ALL BUILDINGS AND STRUCTURES - WIIEN COMPLETED AND READY FOR OCCUPANCY AND USE -- UBC SEC. 305 (d). 1, Concrete for foundations and load bearing slabs is required to be 3000 psi in 28 days - UBC Chapter 26. Mortar and grout shall be In accordance with UDC Chapter 24 & Table 24 -A and 24 -11. 2. Masonry units, mortar, and grout shall he protected during cold weather In accordance with UBC Sec. 2404 (c). Concrete shall he protected during cold or hot weather in accordance with URC Sec. 2605 (f) and (g). 3. Minimum concrete and /or masonry foundation reinforcement requirements are shown on the attachment. (Note: these minl.iuma apply only if a foundation soils investigation Is not performed and the Boils are assumed to have an expansion index of 20 or less and footing loads lose than 2000 lbs /linear foot - UBC Sec. 2904 (a) and (b ) and Sec. 2906. 4. Foundation frost protection is 30" from finished grade to top of footing - UBC 2907 (a). (5) Foundations shall extend a min. Of 6" above finished grade - UBC 2907 (d). 6 Provide for the control and drainage of surface water away from the building UBC 2907 (f). 7. Foundation walls enclosing a basement below grade shall be damp - proofed on the exterior with approved materials - UBC Sec. 1707 (d). • - -- 8. Foundation plates or Mills shall be redwood or pressure treated wood (U8C - 2516 (c)), and shall be bolted to the foundation with not leas than 1/2" dia bolts embedded at least 7" into concrete or masonry, spaced not more than 6 feet apart, min. of 2 bolts per piece and within 12" of each end of piece - UBC 2907 (f). 9. Exterior concrete or masonry piers shall extend 0" min. above grade unless the posts or columns which they support are treated or decay resistant wood. Columns and posts located in basements shall be supported by concrete piers or metal pedestals extending 6" min. above earth and 1" min. above floor unless treated nr decay resistant wood - UBC Sec. 2516 (c) 4. 10. Manufactured trusses, and manufactured joists and beams (i.e. TJI /Micro- Lams, DCI /Versa -Lams, Glu -Lams, etc.), shall be sized and installed in accordance with the manufacturers requirements. 11. Wood joists or floor beams located closer than 10" or wood girders cloggn than 12" to the ground in Crawl spaces shall be treated or decay resistant wood - UBC Sec. 2516 (c) 2. 12. Girders supported by masonry or concrete shall have 1 /2" air space at top, sides, and ends unless treated or decay resistant wood - UBC Sec. 2516 (c) 5. Ends of beams and girders Shall have min. 3" of bearing on masonry or concrete - UBC Sec. 2517 (c). 13. Floor joists under and parallel to bearing partitions shall be doubled UBC 2517 (d) 5. 14. Floor joists require full depth solid blocking and must lap a min. of 3" over bearing supports - UBC 2517 (d) 3. 15. Beams, roof rafters, and ceiling and floor joists shall be supported laterally in accordance with UBC 2506 (h). 16, Columns, posts, beams, and girders shall have positive connections provided to ensure against both uplift and lateral. displacement - UDC Sec. 2516 (m). 17. Ends of floor joists *shall have 1 1/2" min. bearing on wood or metal and no loss than 3" on concrete or masonry - UBC Sec. 2517 (c) and (d) 2. 10. Notches on the ends of floor joists - max. 1/4 joist depth. Bored holes not within 2" of top or bottom of joist and hole diameter no larger than 1/3 depth of joist. Notches at top or bottom shall not exceed 1/6 depth and not located in middle 1/3 span - UBC Seca 2517 (d) 3. 19. Floor joists and /or roof rafters are insufficient for the span - UBC Table 25 -V-J -1 and UDC Standards. (2", Roof live load (snow load) shall be 40 psf below 7,000 feet elevation -UBC Sec. 2305 (d) -dead loads shall he as required in UBC Sec. 2305. (1 :.- ) 1, 0' / � '.I 7 'v'i ( . � . ) i S i" I CAR , y5) / II / I I L ! I . 11-^-1 '.(Ylr , . ' I }) 1 {'. e I I L. F /r 1 ! YYY / r / `i ' ( iI 'r � l ! k - . �� 11'a �l )..) . I ( ( . I fr'I') 0 l 1.1i/ fil ,()CT Eli 4, / 1 I I I / Ili i) I' d ) ( o `) )I ( 7 / 21. Floor live load shall be 40 psf - UUC Bec.2304 (a) and Table 23 -A -1 - dead loads shall be as required in UBC Sac. 2304. Basic wind speed shall be 80 mph - UBC Sec. 2311. 3. Headers over wall openings 4' wide of less shall be doubled 2" framing lumber on edge. Over 4' wide the header shall be sized for the (span - UBC Sec. 2517 (g) 5. 24. Bearing walla supporting two floor loads are required to be a min. of 3" x 4 "or 2 "x 6" studs with a max. spacing of 16" on center -UBC Sec. 2517 (g) 1. 25. Wood studs may be cut or notched to a depth not exceeding 25% of width In exterior walls and bearing partitions and not exceeding 409 of width in non- bearing partitions - UBC Sec. 2517 (q) 8. 26. Wood studs may have bored holes no greater In diameter than 40% of stud width, 609 of width of doubled studs (but not more than 2 successive doubled studs). No holes shall be bored nearer than 5/8" to edge of stud - UBC Sec. 2517 (g) 9. 27. Wall bracing required both sides of each corner and every 25 lineal feet - the braced panel must be a min. of 40" in width perpendicular to studs - UBC Sec. 2517 (g) 3. 28. Approximate min. insulation values are n -19 walla, N -25 roofs, and R -11 floors over unheated space - see plans for more specific requirements - "Colorado Energy Conservation Standards." 29, Foam plastic Insulation shall be separated from the building interior, including attics and crawl spaces, in accordance with UBC Sea. 1712. Other insulation (including duct and plenum insulation and coverings per UMC Chapter 10) including facings shall meet the requirements of UBC Sec. 1713. 30. Masonry and atone veneer units (5" max. in thickness) shall have min. site of No. 22 gauge by 1" gale. metal ties or No. 9 gauge gals. wire ties and spaced to support not more than 2 sq. ft. of wall area but not more than 24" on center horizontally.. When applied over stud construction, the studs shall be max. of 16" on center. Approved building paper must be applied over the sheathing or studs - UBC Sec. 3006 (d). 31. Ceiling height is required to be 7'6" in all rooms except kitchens, hallo, bathrooms, and storage areas which may be 7'0" min. - UBC Sec. 1207 (a). ---- 32. Min. stairway headroom clearance is 6'8" - UBC Sec. 3306 (p). --- 33. Min. stairway width is 36" - UBC Sec. 3306 (b) and min. landing dimension in the direction of travel must also be 36" - UBC Sec. 3306 (g). 34. Stairways max. run 9 "1 max. rise 8 "; max. variation in rise and run 3/8" - UBC Sec. 3306 (C). 35. Enclosed usable space under interior and exterior stairways shall be protected on the enclosed side as required for one -hour fire- resistive construction - UBC Sec. 3306 (m). Fire stops shall be provided In accordance with UBC Sec. 2516 (f) 2c. 36. Stairway handrails' min. height 34 "1 max. height 38 "; handgrip portion shall be not lees than 1 1/2" nor more than 2" in x- section dimension, Min. of one handrail required on all stairways with more than three risers. Min. 1 1/2" space required between wall and handrail -- UBC Sec. 3306 (j). 37. Guardrails of 36" min. height shall be installed at unenclosed floor openings end open sides of stairways, landings, ramps, decks or porches more than 30" above grade or floor below. Open guardrails shall have a pattern such that a sphere 6" in dia. cannot pass through - UBC Sec. 1711. 30. Under -floor (crawl apace) cross ventilation is required equal to 1 sq. ft. for each 150 sq. ft. of under -floor area - use Sec. 2516 (c) 6. 39. Under -floor areas shall be provided with a min. 18" by 24" access opening - UBC Sec. 2516 (c) 2. 30" by 30" min. if mechanical equip. in under -floor area - UMC Sec. 709. 40. All sleeping rooms below the fourth story without a door opening to the exterior shall have at least one operable window that meets the following requirements! MAXIMUM sill height! 44" MINIMUM net clear opening height' 24" (x34 1/4" + 5.7 sq.ft.) MINIMUM net clear opening widths 20" (x41" - 5.7 sq. ft.) This also applies to basement sleeping rooms -. UBC Bec, 1204. 41. Glazing in hazardous locations as defined in UBC Sec. 5406 (glazing In doors and adjacent to doorways, and glazing in windows located within 10" vertically of a walking surface) shall be safety glazed or protected. 42. Glass in eloped glazing (more than 15 from the vertical and skylights shall meet the requirements of UBC Chapter 34. Skylights and roof and wall panels of light - transmitting plastics shall meet the requirements of UBC Chapter 52. 43. Provide combustion air for fuel burning equipment per UMC Chapter 6. 44, Pressure relief valves and /or combination pressure /temperature relief valves shall be provided with a drain line to a floor drain with min. 1" air gap • or extended to the exterior of the building - UPC Sec. 1007. 45. Domestic dishwashing machines shall not be directly connected to a drain or waste disposer without the use of an approved airgap - UPC Sec. 608 (d): 46. Fuel burning appliances shall not be located in any room used or designed to be used as a sleeping room, bathroom, or closet or any enclosed apace opening into such room or space* UPC Sec. 1309 and UMC Sec. 704 (unless listed for such use). 47. Appliances (including space heating and water heating equipment) shall be accessible for repair and removal In accordance with the UMC. 48. LPG 'fueled appliances shall not be installed in a pit, under -floor (crawl) apace, or basement - UMC Sec. 504 (f). 49. Appliances located in a garage (or in an enclosure opening into a garage) shall be located out of the normal path of vehicles or protected from damage. Any portion of the appliance creating a flame, spark or glow shall be installed a min. of 18" above the garage floor - UMC Sec. 500. 50. Each water closet stool shall be located in a clear space not lees than 30" in width and 24" in front of stool - UDC Sec. 511 (a). 51. Toilet rooms without operable windows shall be equipped with an exhaust system ducted to the exterior - UBC Sec. 1205 (c). 52. Showers and Tub /Shower enclosures shall have a smooth, hard, nonabsorbent surface to a height of 70" min. above the drain inlet - UBC Sec. 510 (b). Water- renistent gypsum board shall not be used over vapor barriers, in saunas or steam rooms, or on ceilings - UDC Sec. 4712. • 53. Attic access opening of not less than 22" by 30" is required - UDC Sec. 3205 (a). 30" by 30" if mechanical equip. In attic Space - UMC Sec. 708. 54. Enclosed attic and rafter spaces shall have cross ventilation of min. 1 /150 of the area of the space ventilated. The area may be 1/300 if provided equally at lower and upper portions of the space with min. 3' vertical separation of locations - UBC Sec. 3205 (c). 55. Garage side of common wall between living apace and garage shall be finished with materials approved for one -hour fire- resistive construction. This also applies to ceilings and bearing walls if living apace above the garage. Self closing min. 1 3/8" solid door is required between house and garage-- nee 503 (d) 3. 56. Electrically wired, interconnected smoke detectors are required in all Bleeping room access areas, near the top of stairways in upper levels, and near the bottom of stairways to basements - Use Sec. 1210 (a). 57. Wood stoves and factory built chimneys, and manufactured fireplace units and venting systems shall be installed in accordance with the manufacturers listing requirements and inspected during installation UMC Chapter 9 and UDC Chapter 37. 58. Masonry and concrete fireplaces and barbecues shall meet the requirements of UDC Chapters 23, 24, 26, 27 and 29. A chimney shall not support any structural load other than its own weight unless designed as a supporting member - UBC Sec. 3703 (a). 59. 60. COPIES Of THE ITEM(S) CHECKED BELOW ARE ATTACHED (Copies of any of the items above or below are available upon request). Excavations, fills, foundations, and retaining walls - UDC Chapters 23 and 29. ___.. Retaining walls - UBC Sec. 2308 (b) and 2907 (g) 4. Roof coverings and drainage - UDC Chapter 32 (Roof drains sized in accordance with UPC Appendix D). Roof sheathing - (SC Sec. 2516 (1). - Wood combined with (supporting) masonry or concrete - UDC Sec. 2515. Floor sheathing - UDC Sec. 2516 (h). Wiring In plenums - UMC Chapter 10 and NEC. , Fire and draft stops - UBC Sec. 2516 (f). Hailing requirements for connecting wood members - UBC Sec. 2516 ()). Enclosure of elevator, vent, and dumbwaiter shafts, and clothes and rubbish chutes - USC Sec. 1706. _ Exterior wall coverings and exterior weather protection - UBC Sac. 1707 (d) and 2516 (g). - Interior application of gypsum wallboard and interior and exterior application of lath and plaster - (inc Chapter 47. Manufactured wall and ceiling covering systems (simulated stucco, etc.) shall be installed in accordance with manufacturers requirements. Landings and floor level at doors - UBC Sec. 3304 (i). - Cross connection control and back flow prevention - UPC Sec. 1002 and 1003. Treated Wood Foundation Systeme - UDC Standard 29 -3. f or ( P o .) . - 3 . 01 .m T t ' Ce 0 ( (> i, a ! 7 ' 1 . Q2 .- I J 9 ■ 9Dz Li Ur G 4?c. z. Y , ' 1 C;14 (1 3 o . ( • 8� n --..... ■EM ': t. " ... ll I .. 1 1 , , Fr! , O ::;,, !:!! • ,,,,,,,,..... ,,,.. ........... mow. , ?: JEt Y -II p3 Y - g , 1 - _ , err — � � .r� � 1 S a l ,r s 111 . rr— ._.. .... _. I � J • i; � -_ ZY — y1 — 1t -,. 0 CI ® _ }_ . .. • Fit: iq • • YM a . 1tl_k✓kY.w ..� 4 4 •0 i1 ! • 47 :$1 f v'1 Fic„ ._— _.. ii yy � - i F i — — ....... _._._ ■ !' Y 4 11 � r r _._.. ......... _....... 3.1 n ,4 y I1A ' • wt— ...... • II 1 • r as Pam 3 . 9 ,_ o „ F mo L J M y tr aF` .� n \, o y Q, pp q e v N I N ii =p t i ` ,<: ect-al I, 48 : a 4uw. b 's• q 8 i ra n } F� { 4/ 5. 8',.l _ r 5 K i T L_ R """n g ; n8 �_ g ." }gv^�""vx .. y g ver, u n 1 bo : ' Rns Feu••r�� u ' K ` -- ... yC Y e b ^ . e. u gfleio I' u *� pi $ E F ,. ac . Y.^q..' „ S.`q-P . wa.agr r -g ^ ^� .' a r •75•. . /i n e eRI4- n - -314... ;"';`?P n� y �a- r. Q- In I p n zi ` . v r .toon- R bl • ; h �- �5 a.nn. " :u n - S &no,". "'g nc °n w +mom yy wk at Sj 2"rn 2 L7 .8; Wtl� Si = 8' Q tt 1 8 :it " Br E . $ 3 " ^w and 2S-:,.° ji a re �i ry q �• yy Q ,o ^ „ 0 ..,n w P% O � , O i a • Y ' Si R N S' » n npu d •` to -4 °15 w :HEN S EC _ . p F R ' 2 e t n•° lm ,. ° v is ° S • , N .0. g S Z t $tl 2 cu 1 . 0 2 M -fin °12.22 W :. ` o �; o.,� ;h (yyr� • £ L ,yy� i i °' ` o e : ^ q — 1 S N p r q N. » 22:42 n q . y u a N ' t BUIItDINC� (PERMIT °' GA `W' W COUNTY, OLORAD - -- . � DatF ( (cited Area Permit No `tom r ►^ .. s AGREEMENT i , ' ri.constderatt cif the is supnce of this permit, the applicant hcrehy agrees to comply with i, a - - - `W iyllaaKd'regula[iorts related to the zoning, location; construction atir°rcction of the proposed structuretfor which this permit is granted, and further agrees that if the above said regulations a`rennot fully complied with in the zoning, location, erection and construction of the above described Structure, the permit may then he revoked by notice trample County B iI_4 ding Ins l (MME Il peytortat COME ILL�VO� Ilse C V Coty �C��1+�C � ( �"� Q �iP y r , Address or Legal Description �J n . .,. Uwner '�e�I / �,�t��� Contractor �D„� Setbacks Front Side Side Rear _ This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection. INSPECTION RECORD Zoning Roof Covering I Footing , Foundation Plumbing - Underground MIES Heating Ventilation nla n insulation I ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING — WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND, THIS PEBMIT'I5 NOT TRANSFERABLE Phone 945-$212 109 8th Street i, ', County Courthouse, Glenwood Springs, Colo. A z Dat f j 1 At BY . ,roT � 4 • tm nr TS' r)P,= C N'T1T ( ? \ T'T.: \STTC