Loading...
HomeMy WebLinkAbout4360 ' ., ; 9. 04360 GARFIELD COUNTY BUILDING, SANITATION and PLANNING DEPARTMENT 109 8th Street Suite 303 Glenwood Springs, Colorado 81801 (303) 945 -8212 Job Address C,11. 260. Silt Nature of Work 1,biding; Permit Use of Building Detached Garage Owner Donal ci W. tar son Contractor . °` r Amount of Permit: $ 3 l ` " ^ 5(1 Date: Octob r 28, 1991 Pemit $90 " O(? Tian $ R. Bennett Clerk White-Treas. Canary -Office Pink - Applicant Gold - Duplicate GARFIELD COUNTY APPLICATION FOR BUILDING PERMIT / / 2/ PERMIT NUMBER � rJ0 please print or type DATE e Q I( ZZ , /4 r / TO BE FILLED OUT BY APPLICANT PLOT PLAN ADDRESS 41,5157 /Cp, i✓a, D• 5/g4ei, NOTE: Show casements, property line dimensions, SUBDIVISION all other structures, specify north, and street - IFILTNG # TOT # BLOCK # name. For odd shaped lots, or if space i5 PI TAX SCHEDULE # 4•200/26P „,_,� too small, provide separate plot plan. LEGAL (SEC/TWN/RNG) _ # OF BUILDINGS NOW ON PARCEL - p+ NAME TV A/#4.0 LI�/?$ w �..� USE OF BUILDINGS NOW ON PARCE �— �� /v0S t u., „, / 2, / s n.*, .1( et, 9/L5 e (MAILING ADDRESS �slid �lpQ I e CITY 3M 'r — " HONE g i u, a NAME m ADDRESS _ CITY a NAME... - __..- o ADDRESS _ g CITY _ F g °HONE LICENSE # CLASS OF WORK NEW ALTERATION ADDITION ____ Nu_ DEMOLISH __ _ REPAIR _ MOVE __ MOBILE NOME. (make /model) AI'�_ Si?. OF' BUILDING 7417 S.F. OF LOT 043 4c , # OF FLOORS -� _ HEIGHT •' I-- /( 2 # OF FAMILY UNITS N ,A # OF BEDROOMS iV A- INTENDED USE OF BUILDING C','ety 0 - yc'/S„} r.a4“ :- GARAGE: SINGLE. DAL _ CARPORT: SIMILE DAL __ _w FRONT PROPERTY LINE FIREPLACE DOCUMENTS ATTACHED STREET NAME /ROAD NUMBER WATER SUPPLY ALA_ CHECK IF CORNER LOT DRIVEWAY PERMIT NA __... DESCRIPTION OF WQRK / PLANED SITE PLAN Le- ( -2n S i/'cE C ' - w.. ir C1 a i o cf 9 BUILDING PLANS L` •.! ✓ SANITARY SEWER CLEARANCE ,/,.4 __ I hereby acknowledge that I have read this ON SITE SEWAGE DISPOSAL PERMIT /(j / - application and the above is correct and I OTHER DOCUMENTS (Specify) agree to comply with all county ordinances m--... state laws regplg building construction / /' (( Y+ _.,,. .z s. Q ,�P. /n'r6+ ec, 6n nz! Y ,OR °/7 OF USE _._ VALUATION � A O b J -- FLOOD HAZARD PERMIT FEE $ Q, 00 PLAN ! ! CHECK FEE $ S 0 CERTIFIED BLDG ELEVATION — TOl'AL FEE $ SO SCHOOL IMPACT FEE $ // 4 SPECIAL CONDITIONS DATE PERMIT TS.SUED ZONING DISTRICT PROBLEMS WITH PERMIT TYPE OF OCCUPANCY' V A A TYPE OF CONSTRUCTION Al ADDITIONAL INFORMATION NEEDED S.F. OF BUILDING 77 S.F. OF LOT [f, 9aI MAX. HEIGHT I , r, �. ROAD CLASS. .---- _ CERTIFIED BY COLORADO REGISTERED LAND SURVEYOR SETBACKS FROM PROPERTY LINE: FRONT OR ENGINEER REAR RIGHT _ LEFT OFT STREET PARKING SPACES REQUIRED 97 �Io APPROVED: .011-:___,,,„i I j Ij erg . 0 . 2 z 7 APPROVED: ;r . /,A0-,.., / leX ILDING DEP” T TE PLRNN C' DEPA'T r .+` DATE I I L..meso /0/--d- �Y /f I II Ii II 9A>cl A7:1111 ji II; T I I ��I Ii ii ii Al i II i i rrr .w.,. -. ... 1.7 5 S R 92 h OF THE 77/ P Pg. NOTE: . Bearings and distances on this map according to Document number 272264 unless otherwise noted. t. SE %4NE (See. 34) V Sel Reber 4. Cap se Sen'finn /Inc 6 r .. 41) • 4 r . p CZI U T CZ) e iW 4 ■ r N y5o 0 76.0' 11 40 I W ' o4Q .4 C1tt- ur h 6 Werl Porter ' f. _ i ✓ole - i of Reber WES 440.00' r ff. Vet Corner Cap 8130. gg//n� 340 d e60 - ` r . -- — — k l SC/94 e i,wcN- loo rssr . I 0 1 NE Y4 SE Y.4 0 l (Sec• 34) •960 Aunt,:; This is to certify that on the 26th day of July, 1976, there was a survey made by SCARROW AND WALKE, INC., of the improvements on a parcel of land - situated in tho SEkNE;, of Section 34, Township 5 South, Range 92 West of the Sixth Principal Meridian, County of Garfield, State of Colorado, said parcel of land descrihad in Coument number 272264 of The Garfield County Records. There was found a nn,a story house of frame construction with full basement, concrete foundation and asphalt shingle roof to be located as shown on this plat. The location and dimensions of all buildings, improvements., easements and rights -of- ways in e,vi,dence or known to me and encroachments by or on the piemiso aFo accurately Shown. SCARRO'W AND WALKER, INC. P.O. BOX 460 GLENWOOD SPRINGS, COLORADO 1 d PERMIT IF OWNER oAl Lies LOCATION (7S 35 (; /2c/1Z4 ro CONTRACTOR _ THE FOLLOWING ITEMS MAY RAVE BEEN OMITTED FROM YOUR PLANS OR MAY NOT COMPLY WITH THE PROVISIONS OF THE UNIFORM BUILDING CODES. PLEASE CHECK ALL CIRCLED ITEMS BEFORE BEGINNING CONSTRUCTION. ALL REFERENCES ARE 1988 EDITIONS OF THE CODES. THESE ITEMS ARE REQUIREMENTS FOR R -3 OCCUPANCIES ONLY (ONE AND TWO FAMILY DWELLINGS) AND ARE NOT ALL INCLUSIVE OF THE CODE REQUIREMENTS, BUT ARE MEANT AS A GUIDE TO SOME OF THE HOST OFTEN ENCOUNTERED QUESTIONS RELATED TO CODE REQUIREMENTS. THE APPROVED PLANS RETURNED TO YOU SHALL BE KEPT AT THE BUILDING SITE DURING CONSTRUCTION. FOR ANY REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE CONTACT THE COLORADO ELECTRICAL INSPECTOR. THERE SHALL BE A. FINAL INSPECTION AND APPROVAL OF ALL BUILDINGS AND STRUCTURES WHEN COMPLETED AND READY FOR OCCUPANCY AND USE - UDC SEC. 305 (d). a ? Concrete far foundations and load bearing slabs le required to be 3000 poi in 28 days - UBC Chapter 26 Mortar and grout shall be in accordancs with UBC Chapter 24 & Table 24 -A and 24 -B. Masonry units,'mortar, and grout be protected during cold weather i.n accordance with UBC Sec 2404 (c) Concrete ehai.l be protected during cold ari hot weather in accordance wit UBC Sec. 2605 (f) and (g). 0 :1_) Minimum cvnorete and /ox mason foundation reinforcement requirements are shown on the attachment (Note: these minimums apply only if a foundation soils investigation is not performed and the soils are assumed to have an expansion index of 20 or less and footing loads lean than 2000 lbs /linear foot - UBC Sec. 2904 (a) and (b) and Sec. 2906. 4. Foundation frost protebtion is 30" from finished grade to top of footing - UBC 2907 (a). Foundations shall extend a min. " above finished grade - UBC 2907 (d). 6 Provide for the control and drainage of 6 of surface water away from the building - UBC 2907 (f). 7. Foundation walls enclosing a basement below grade shall be damp - proofed on the exterior with . approved materials - UBC Sec. 1707 (d). - -- 0) Foundation plates or sills shall be redwood or pressure treated wood (UBC - 2516 (c)), and shall be bolted to the foundation with not less than 1/2" dia bolts embedded at least 7" into concrete or masonry, spaced not more than 6 feet apart, min. of 2 bolts per piece and within 12" of each end of piece - UBC 2907 (f). 9. Exterior concrete or masonry piers shall extend 8" min. above grade unless the posts or columns which they support are treated or decay resistant wood. Columns and posts located in basements shall be supported by concrete piers or metal pedestals extending 6" min. above earth and 1" min. above floor unless treated or decay resistant wood - UDC See. 2516 (c) 4. 10 Manufactured trusses, and manufactured joists and beams (i.e. TJI /Micro- Lams, BCI /Versa- -Lams, Glu - Lams, etc.), shall be sized and installed in accordance with the manufacturers requirements. 11. Wood joists or floor beams located closer than 18" or wood girders gjoser Khan 12" to the ground in crawl spaces shall be treated or decay resistant wood -- UBC Sec. 2516 (c) 2. 12. Girders supported by masonry or concrete shall have 1/2" air space at top, sides, and ends unless treated or decay resi wood - UBC Sec. 2516 (c) 5. Ends of beams and girders shall have min. 3" of bearing on masonry or concrete - UBC Sec. 2517 (c). 13. Floor joists under and parallel to bearing partitions shall be doubled UBC 2517 (d) 5. 14. Floor joists require full depth solid blocking and must lap a min. of 3" over bearing supports - UBC 2517 (d) 3. 15. Beams, roof rafters, and ceiling and floor joists shall be supported laterally in accordance with UBC 2506 (h). 16. Columns, posts, beams, and girders shall have positive connections provided to ensure against both uplift and lateral displacement -- UBC Sec. 2516 (m). 17. Ends of floor joists shall have 1 1/2" min. bearing on wood or metal and no less than 3" on concrete or masonry - UBC Sec. 2517 (c) and (d) 2. 10. Notches on the ends of floor joists - max. 1/4 joist depth. Bored holes not within 2" of top or bottom of joist and hole diameter no larger than 1/3 depth of joist. Notches at top or bottom shall not exceed 1/6 depth and not located in middle 1/3 span - UBC Sea. 2517 (d) 3. 19. Floor joists and/or roof rafters are insufficient for the span - UBC Table 25 -V -J -1 and UBC Standards. Roof live load (snow load) shall be 40 psf below 7,000 feet elevation -UBC sec. 2305 (d) -dead loads shall be as required in UBC Sec. 2305. 21. Floor live load shall be 40 psf - UBC Sec.2304 (a) and Table 23 - - - dead loads shall be as required in UBC Sec. 2309. Basic wind speed shall be 80 mph - UBC Sec. 2311. Headers over wall openings 4' wide or less shall be doubled 2" framing lumber on edge. Over 4' wide the header shall be sized for the span - UBC Sec. 2517 (g) 5. 24. tearing walls supporting two floor, loads are required to be a min. of 3" x 4 "or 2 "x 6" studs with a max. spacing of 16" on center -UBC Sec. 2517 g) 1, 25. Wood studs may be cut or notched to a depth not exceeding 25% of width in exterior walls and bearing partitions and not exceeding 40% of width in non- bearing partitions - UBC Sec. 2517 (g) 0. 26. Wood studs may have bored holes no greater in diameter than 40% of stud width, 60% of width of doubled studs (but not more than 2 successive doubled studs). No holes shall be bored nearer than 5/8" to edge of stud - UBC Sec. 2517 (9) 9• 27 Wel). bracing required both sides of each corner and every 25 lineal feet -- the braced panel must be a min. of 48" in width perpendicular to studs - UBC Sec. 2517 (g) 3. 28. Approximate min. insulation values are R -19 walls, R -25 roofs, and R.-11 floors over unheated space - see plans for more specific requirements - "Colorado Energy Conservation Standards." 29. Foam plastic insulation shall be separated from the building interior, including attics and crawl spaces, in accordance with UBC Sec. 1712. Other insulation (including duct and plenum insulation and coverings per UMC Chapter 10) including facings shall meet the requirements of UBC Sec. 1713. 30. Masonry and stone veneer units (5" max. in thickness) shall have min. size of No. 22 gauge by 1" galv. metal ties or No. 9 gauge galv. wire ties and spaced to support not more than 2 sq. ft. of wall area but not more than 24" on center horizontally. When applied over stud construction, the studs shall be max. of 16" on center. Approved building paper must be applied over the sheathing or studs - UBC Sec. 3006 (d). 31. Ceiling height is required to be 7'6" in all rooms except kitchens, halls, bathrooms, and storage areas which may be 7.0" min. - UBC Sec. 1207 (a). - - -- 32. Min. stairway headroom clearance is 6"8" - UBC Sec. 3306 (p). - --- 33. Min. stairway width is 36" - UBC Sec. 3306 (b) and min. landing dimension in the direction of travel must also be 36" - UBC Sec. 3306 (g). 34. Stairways max. run 9 "; max. rise 8 "; max. variation in rise and run 3/8" - UBC Sec. 3306 (c). 35. Enclosed usable space under interior and exterior stairways shall be protected on the enclosed side as required for one - hour fire - resistive construction. - UBC Sec. 3306 (m). Fire stops shall be provided in accordance with UBC Sec. 2516 (f) 2c. 36. Stairway handrails: min. height 34 "; max. height 38 "; handgrip portion shall be not less than 1 1/2" nor more than 2" in x- section dimension. Min. of one handrail required on all stairways with more than three risers. Min. 1 1/2" space required between wall and handrail - UBC Sec. 3306 (j). 37. Guardrails of 36" min. height shall be installed at unenclosed floor openings and open sides of stairways, landings, ramps, decks or porches more than 30" above grade or floor below. Open guardrails shall have a pattern such that a sphere 6" in dia. cannot pace through - UBC Sec, 1711. 38. Under -floor (crawl space) cross ventilation is required equal to 1 sq. ft. for each 150 sq. £t. of under - floor area - sec Sec. 2516 (c) 6. 39. Under -floor areas shall be provided with a min. 18" by 24" access opening - UBC Sec. 2516 (c) 2. 30" by 30" min. if mechanical equip. in under -floor area - UMC Sec. 709. 40. All sleeping rooms below the fourth story without a door opening to the exterior shall have at least one operable window that meets the following requirements: MAXIMUM sill height: 44" MINIMUM net clear opening heights 24" (x34 1/4" 5.7 sq.ft.) MINIMUM net clear opening width: 20" (x41" a 5.7 eq. ft.) This also applies to basement sleeping rooms - UBC Sec. 1204. 41. Glazing in hazardous locations as defined in UBC Sec. 5406 (glazing in doors and adjacent to doorways, and q) in windows located within 18" vertically of a walking surface) shall be safety glazed or protected. 42. Glass in sloped glazing (more than 15 from the vertical) and skylights shall meet the requirements of UBC Chapter 34. Skylights and roof and wall panels of light - transmitting plastics shall meet the requirements of UBC Chapter 52. 43. Provide combustion air for fuel burning equipment per UMC Chapter 6. 44. Pressure relief valves and /or combination pressure /temperature relief valves shall be provided with a drain line to a floor drain with min. 1" air gap or extended to the exterior of the building - UPC Sec. 1007. 45. Domestic dishwashing machines shall not be directly connected to adrain or waste disposer without the use of an approved airgap - UPC Sec. 608 (d): 46. Fuel burning appliances shall not be located in any room used or designed to be used as a sleeping room, bathroom, or closet or any enclosed space opening Into such room or space* UPC Sec. 1309 and UMC Sec. 704 (unless listed for such use). 47. Appliances (including apace heating and water heating equipment) shall be accessible for repair and removal in accordance with the UMC. 48. LPG fueled appliances shall not be installed in a pit, under -floor (crawl) space, or basement - UMC Sec. 504 (f). 49. Appliances located in a garage (or in an enclosure opening into a garage) shall be located out of the normal path of vehicles or protected from damage. Any portion of the appliance creating a flame, spark or glow shall be installed a min. of 18" above the garage floor - UMC Sec. 508. 50. Each water closet stool shall be located in a clear space not less than 30" in width and 24" in front of stool - UBC Sec. 511 (a). 51. Toilet rooms without operable windows shall be equipped with an exhaust system ducted to the exterior -. UBC Sec. 1205 (c). 52. Showers and Tub /Shower enclosures shall have a smooth, hard, nonabsorbent surface to a height of 70" min. above the drain inlet - UBC Sec. 510 (b). Water- resistent gypsum board shall not be used over vapor barriers, in saunas or steam teems, or on ceilings - URC Sec. 4712. 53. Attic access opening of not less than 22" by 30" is required - UBC Sec. 3205 (a). 30" by 30" if mechanical equip. in attic space - UMC Sec. 708. 54. Enclosed attic and rafter spaces shall have cross ventilation of min. 1/150 of the area of the space ventilated. The area may be 1/300 if provided equally at lower and upper portions of the space with min. 3' vertical separation of locations - UBC Sec. 3205 (c). 55. Garage side of common wall between living space and garage shall be finished with materials approved for one -hour fire - resistive construction. This also applies to ceilings and bearing walls if living space above the garage. Self closing min. 1 3/8" solid door is required between house and garage- - UBC 503 (d) 3. 56. Electrically wired, interconnected smoke detectors are required in all Bleeping room access areas, near the top of stairways in upper levels, and near the bottom of stairways to basements - UBC Sec. 1210 (a).., 57. Wood stoves and factory built chimneys, and manufactured fireplace units and venting systems shall be installed in accordance with the manufacturers listing requirements and inspected during installation UMC Chapter 9 and UBC Chapter 37. 58. Masonry and concrete fireplaces and barbecues shall meet the requirements of UBC Chapters 23,24, 26, 27 and 29. A chimney shall not support any structural load other than its own weight unless designed as a supporting member - UBC Sec. 3703 (a). 59. 60. COPIES OF THE ITEM(S) CHOCKED BELOW ARE ATTACHED (Copies of any of the items above or below are available upon request). Excavations, fills, foundations, and retaining walls - UBC Chapters 23 and 29. Retaining walls - UBC Sec. 2300 (b) and 2907 (g) 4. Roof coverings and drainage - UBC Chapter 32 (Roof drains sized in accordance with UPC Appendix D). Roof sheathing - UBC Sec. 2516 (i). Wood combined with (supporting) masonry or concrete - UDC Sec. 2515. Floor sheathing - UBC Sec. 2516 (h). Wiring in plenums - UMC Chapter 10 and NEC. Fire and draft stops - UBC Sec. 2516 (f). Nailing requirements for connecting wood members - UBC Sec. 2516 (1). Enclosure of elevator, vent, and dumbwaiter shafts, and clothes and rubbish chutes - URC Sec. 1706. Exterior wall coverings and exterior weather protection - UBC Sec. 1707 (d) and 2516 (g). Interior application of gypsum wallboard and interior and exterior application of lath and plaster - UBC Chapter 47. Manufactured wall and ceiling covering systems (simulated stucco, etc.) shall be installed in accordance with manufacturers requirements. _ Landings and floor level at doors - UBC Sec. 3304 (1). Cross connection control and back flow prevention - UPC Sec. 1002 and 1003. _,,,� Treated wood Foundation Systems - UBC Standard 29 -3. Rr :; M1 , • 32' -O" • • O '. t • • • k 1 1 1 n 9. SHOP AREA A l III � u11 1 __ It 1 • I i 111 : I i i� • r I ` � , I ^ � I LOCATE ODOR AND WINDOW AS AF,S6kE0 DOOR :. W • 16' x 7' OVERHEAD SECTIONAL ODOR I 0 'L - LONLAEIE A PROII . . yu' S . s ; � _; 36" x M, XIXOON -. ,.� • • • • . 1r-- -1 ~ • 32' -O • N • • • FLOOR PLAN T WO AUTO GARAGE WITH WORK SHOP • -_ Z ROOFING SHINGLES • �w w�ill�iD�ww� Twrrw w ��ww - - w "4rwwrrwww ROOF aww wwwwrrwwwwwr 1i l PI TLH • 12/4 • OMEN www www www www Tiw rDIrDNrrLwwwww • i ww' i i' 1" w 5 -5Z �� �� l =MIME I= w . . i. .. =nur- _Z_--- w__- fl_-- wa_ --- . -w ^rte M ^_w 1 x 6' FASCIA • METAL COR NER RNER TRIM 16' z T' OVEAIIEAD - -- , - -- A' DOOR TRIM JINNI l .= 1' N la ' a SE[TIONAL DOOR • • DIM GLASS LITES HORIZONTAL LAP SIDING ' —. , - _...... n .r -: • ' . FRONT ELEVATION • ' ''''' GARAG MODEL • • .f MA it DL 2432 © 1985 • 0 1 x G RAKE BOARD HDR17tfn1Al TAP SIDING M Slin C o • _ D• z 6 — W 8. DOOR b¢iai tx it .SAB4111 _uewAV12 S�zNUBSfsA.Mt RIGHT ELEVATION PO_______ 17/4 I x6 RAKE BOARD 36" x 36' WINDOW IIO11I2ONtAL LAP SIDING �m�. r ��- a7na�ur l;.r Ve• LEFT ELEVATION • ROOF PITCH - 17/4 ROOFING SHINGLES •�� \� I \, 1/2" ROOF SHEATHING ENGINEERED ' ,! MISSES . IVAL EDGE DRIP ,••!•--- 1 x 6 FASCIA SOFT IT 1/7" FIBERBOARD SHEATHING HORIZONTAL LAP SIDING ' 2 x 4 STUDS AT 16" ON CENTER 4" CONCRETE FLOOR STAB - SLOPE TO DOOR f i T ONE COURSE OF BLOCK AT OVERHEAD DOOR 1" EXPANSION JOINT II N Il u • B <i l Fbh HpET�pryF p i FOOTIRG DElA1Q5 • .. CROSS SECTION II ii —IR IR —. 1 - RII1 0 . . i s . • • i A ' et o f it - • 0. p1 0.61 r'1-a1 /'1•01 I !NW 1 OI ^dl ILp1 r' � � - METAL EDGE DRIP PI' AI,A_._ I 1 x 6 RAGE BOARD "� \'°'"' _ pI11111111PII111P� 901 IIIIIIIIIIIOIIIIIIIIIIIIIIIIL] IIIDII11tl I1111t11111111111111111CIIII' um11111'�� _ RAKE ASSEMBLY J \ LONC0.EIC FOOTING PER LOCAL CODE � COVE MOLDING = a I .. ' I pF I a FINIS l HED FLOOR ELEEM1I ILIN -r c • ..1 ' AI11 4" CONCRETE SLAB DYER WELL CONPACICD 0 1 �• €.4,: ' _I 41 � i } I LLD NN F -INS s LBCAL FI [DBE •REINFDRCE -SLOPE IT TB DDD NIAE ESN PER R STANDARD RAKE s- I 1 Z1 DETAIL Y4 �I • N . -. III S x B x 14 LONCAET BLDCR 11 ��I = � FINISHED ETON ELEVATION 4" i NORIZQNIAL ( I OMIT ON[ COURSE BF BL ACK Al pELN¢ 000R ^ LIP SIDING 2 x 1 TIE PLATE 4\ - a �.�.. = — E L ' ~ . . �.� : " III _ �•,^�,.,��- lulLll]mnlu I uuuLl& i Yi 1/2^ FIBERBOARD __r . ^ ^.„„ 1 •\�1 SHEATHING S J 1 x 4 TRIM II }II .— 2 - 2 x 12 READER 4 II _. P OOP 1. 0-0 ��I -d !! BUILD DOOR HEADER ON SIIE 1 '""I��III'"' '•p Ia Lei ti 1 ortoJ0 12 Yp2 -4 OVERHEAD 00013 1 - S•IS IS sm AR EWR mix 3nr A 11^ FOUNDATION PLAN ANCHOR BOLT LAYOUT HEADER DETAIL Wn f geg o rtr i. Nu" g, ID SDI IFA fWInE 1001 LIYE LMO ®' x IFS 300 •L - Foy 101 ALA MOM IE MAD'AAEAS: suesllml[ 2 01. 1J -5/1/4 • " • 11 -1 /e" muss nisi 0A EQUAL • 000 101 PER SwAM- 1001 Ain LOAD AAG51 WISI Ituit 2 t1d 1 -5 /1" • P• muss J0151 x[IP(AD 00 Lou,µ. • D0A1 1 • 11ry 4" WICREIE SLAB DEER NELC COMPACTED • mar mucus FILL REINFORCED WITH WIRE MESH PER . ANCHOR BOLTS (SEE PLANT " s u DIYHG CYI LOCAL COA SLOPE ID DADA __TREATED WOOD SILL • 1 / Po01 y1QA1x • h • c LISIMIAle 111¢25 IT NI 1 L 1 r MIPI. [WF IMP $ I II N ^ I r y .Ix6CA #IA '� � � "....i:•:1'.1..' x r l ' � � �� n� OM 2 • T no[xlnc •� � I I � ' I i 111 1 tl J I 'r - 1i ' f 17" p1 ELM FAC6I LIAL I III ti . MI. (YET 10111x4- _ ,,,,,,,_.• , [MT. wYAI(A ow 1 _... 4 ' -- 511011 • -- -- DMn.rm.IU ALTERNATE FOUNDATION ^ • " '— TIT IIKAWAW NEAInIRG INAI(D OD SILL pppp��'� DETAIL / ,lT— 2 n 1 ll[dul Rom 51uRS OD 111151(01MSW_AY _ IJS' JA[IMA MIS •v (t(1 1110 0 -0 I II I�I ' gll l � �c l1 111 0 =II - - � :II Tyr '1 F IW ----- I • I • 16 MC"I( S.Dt0 • AaI MWU(s(EW11niRA NOTE: BUILDER TO PROVIDE & Ti "' INSTALL FOOTING & FOUNDATION !•T..0 ; WALL SECTION : 1 • I NOT TO SCALE DIMENSIONS ARE CORRECT INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT GARFIELD COUNTY, COLORADO Date Issucd t 9 / Zoned Area .. Permit No. .- AG EMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice . from the County B 'Idin: I -pec - and IMMEDIATELY BECOME NULL AND VOID, Use , I<`!�. 4 l , Address or Legal Description „ p.� tn.- owner.L,R.� L.\-Id II'c.L Contractor e n fl Q,, Setbacks Front. Side Side Rear This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection. INSPECTION RECORD Zoning Roof Covering Electric -Final (by S'1'A' inspector) Footing 227. S .0 ,%r // / i'" 9/ l- Z - 97 .sf'e,..ia 015 96 Foundation C� Plumbing - Underground Gas Piping Heating Ventilation Frame 1 2 , ' 5° 9)I Insulation j 2 — I H 1 �rr� Plumbing -Rough Drywall / —7 9 �, Electric -Rough N n crk (by STATE inspector) Final / 7 -1z ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING — WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. ' THLS PERMIT LS NOT TRANSFERABLE Phone 945-8212 109 8th Street, County Courthouse, Glenwood Springs, Colo. APPROVED NOT DEST T CARD