Loading...
HomeMy WebLinkAbout4586 N? 045R GARFIELD COUNTY BUILDING, SANITATION and PLANNING DEPARTMENT 109 8th Street Suite 303 _ - Glenwood Springs, Colorado 81601 (303) 945 -8212 Job Address 141 West Tamarack Circle, Battlement Mesa Nature of Work Building, Permit Use of Building Enclose area between Manus Home and detached garage Owner Heinz & Martha Beer Contractor Owner Amount of Permit: $ 118 Date : September 21, 1992 Permit: 72.00 Plan : 46.80 S. Archuleta Clerk White- Treas. Canary- Office - - - - Pink - Applicant - Gold - Duplicate GARFIELD COUNTY APPLICATION FOR BUILDING PERMIT �� PERMIT NUMBER please print or type DATE 9 - 9 7/ Assessor's Parcel # TO BE FILLED OUT BY APPLICANT _ PLOT PLAN ADDRESS AVIV/ 7aeptrof w t NOTE: Show easements, property line dimensions, SUBDIVISIO all other structures, specify north, and street L 5 1FILING # LOT # BLOCK # name. For odd shaped lots, or if space is a TAX SCHEDULE # too small, provide separate plot plan. 'I LEGAL (SEC /TWN /RNG) # OF BUILDINGS NOW ON PARCEL NAME USE OF BUILDINGS NOW ON PAR EL �� z W MAILING ADDRESS �Q 6Os 7 /N(a�?(, hip - o CITY Mo4, efq PHONE 2 5 93/d? era_ free, e • NAME AM- >� a (2: i ADDRESS CITY NAME 01 , l vU e2-- 0 o ADDRESS F I r CITY / o PHONE LICENSE # ( / CLASS OF WORK 1„./..- 0 7 13V0Ved fr 8 ( 9 9 NEW ALTERATION ADDITION DEMOLISH REPAIR MOVE MOBILE HOME (make /model) 4C4- S.F. OF BUILDING S.F. OF LOT # OF FLOORS 1 HEIGHT --{ OF FAMILY UNITS '1 9 F S 1 y� , INTENDED USE OF BUILDING ` di T[ n h 1. -.49c }_e_14 C. GARAGE: SINGLE DBL CARPORT: SINGLE DBL FRONT PROPERTY LINE FIREPLACE DOCUMENTS ATTACIIED _ STREET NAME /ROAD NUMBER WATER SUPPLY __AXE t CHECK IF CO'NP$ LOT DRIVEWAY PERMIT +I DESCRIPT 0 OF WORK PLANNED /l SITE PLAN o r dr 29 e_ I Al d, Wen/ s - e_ • the BUILDING PLANS ✓ — �' y „ o ! AO , , '�:l - f'2 e SANITARY SEWER CLEARANCE N4 (e c& 4 h - I here *, ack that I ave read this ON SITE SEWAGE DISPOSAL PERMIT A aoplic here'', a•di, the above is correct and I OTHER DOCUMENTS (specify) agree • compl 1 with all county ordinances and s a e laws igulating building construction ihummOMMItAlli �2- 6 A � / SIGNA. PI MI �, FOR OFFICE USE ONLY VALUATION "/ 9 0.0, o v FLOOD HAZ.. °D PERMIT FEE $ % ,bb "PLAN CHECK FEE $ `� 1 - 4 ,- d CERTIFIED BLDG ELEVATION TOTAL FEE $ //g c & D SCHOOL IMPACT FEE $ _ A ^ SPECIAL. CONDITIONS l DATE PERMIT ISSUED ZONING DISTRICT /- p 1--1 P PROBLEMS WITH PERMIT TYPE OF OCCUPANCY -- TYPE OF CONSTRUCTION I/ r . N ADDITIONAL INFORMATION NEEDED S.F. OF BUILDING 22_o.l S.F. OF LOT MAX. HEIGHT - / ROAD CLASS. — CERTIFIED BY COLORADO REGISTERED LAND SURVEYOR SETBACKS FROM PROPERTY LINE: FRONTA rhi y,,-, ..e OR ENGINEER REAR RIGHT LEFT OFF STREET PARKING SPACES REQUIRED �! p r APPROVED' _ i_ / /,O /I ., 7 B9 g2_ APPROVED: • q_ZIriz / D T E PLANNING DEPARTMENT DATE O DING DEPARTM iT , c J v et - /� ,, /, - -. 4 a k ti. 7/ / � , ` - - 2 2 C' LL `,,,9 f ' o L -, _ 2 II ( 0/ l (.2 ' Sot..), 3 0 o, _ A f. , �, �� ;:1 � � ,° n - �' - 'f 83. s : - Q. 'A- . _ d-➢ p ..,,aa i �r :�40 r''r -" 44th ' E-, x_ � c.+ksr�+' °'w €rc ^ + *t - -r W-,- '` ....L'nL l "i4 - . Y A Ptc. WI y 4 w x R iL MI6 , tia+: t[x i� - .. a-,� .s �. : : N. t aaffi 3 r-..- ,- • : : : .,# fi j Ni � � T¢ i a :. - i .0 `+ + -tea 7 tM S �1M q N, b. - -- 1 ,a.'. - -+.. ,r is v?s,' s z �,�. xc Ml - , -s. -- r i sw v g � � _ =..� �TS d T a ^ .' s ? } r w of ro. � '_ c - S s ` . � $ c - "wS.:. 45 � 2+ ' s °�YXLx4H�.. �,� �"F � . r : A'a �'a. ! Rif V+S.a h rt M vr ` n j '� "'eY - , + R- ,.,, -a s i.'' .... ., -.' r < — x —4--" r krsi, - x w .�' r " Fa. ..: 'i'`�✓ *' y : s-a- '.r . s ' w .' XS R k `.. a•a � - a.. y am; .- y'M`�.. ._ :'.t"-- . . - r.:: - 3 ... r.6 .. -v J- , - 7---P 4'.., r ' S Ji a • 4 k , • a1 ♦: } • 4 {.i- -' ' s tit 4" nl . ,r q- jp *.' rer7' AI : • N ei is it fi i1 - A ''s% W p : e k N ',....: N x M b e �' .N - • �I I xr • 4„ a.. .iw a ar L. $T S { r�. i MY .off/ g , a. ? - YSF 1 �° k.' , t.',,,. � rv � �} l Y� ~ 1 4 ' t -w -a ar,l . +BL JL � ^ ' ° p' E w. .. 4 . iY- � : - �� l �� YS > ' 2 _emu y Y " ^S� 3: i �-a ,t.rt¢vs LU PERMIT 1 _ OWNERJ2 1/4/ $t(, LOCATION OW 7.r/ r/C/C Ct. CONTRACTOR TIIE FOLLOWING ITEMS MAY HAVE BEEN OMITTED FROM YOUR PLANS OR MAY NOT COMPLY WItti TIIE PROVISIONS OF TIIE UNIFORM BUILDING CODES. PLEASE CHECK ALL CIRCLED ITEMS BEFORE BEGINNING CONSTRUCTION. ALL REFERENCES ARE 1900 EDITIONS OF THE CODES. THESE ITEMS ARE REQUIREMENTS FOR R -3 OCCUPANCIES ONLY (ONE AND TWO FAMILY DWELLINGS) AND ARE NOT ALL INCLUSIVE OF TIIE CODE REQUIUEMEN'TS, OUT ARE MEANT AS A GUIDE TO SOME OF THE MOST OFTEN ENCOUNTERED QUESTIONS RELATED TO CODE RIEQUIREMENTS. TIIE APPROVED PLANS RETURNED TO YOU SHALL. BE KEPT AT TIIE BUILDING SITE DURING CONSTRUCTION. FOR ANY REQUIREMENTS OF TIIE NATIONAL ELECTRICAL CODE CONTACT TIIE COLORADO ELECTRICAL INSPECTOR. THERE SHALL BE A FINAI. INSPECTION AND APPROVAL. OF ALL BUILIIINGS AND STRUCTURES WILE ON LE'TED AND REALLY F 11 QCCUfAti ( Atli) USE - UUC SEC 305 (d). , / 0/ 'tar, 41e :Y rt'jjtlf 41(f7trr ilk (vete ee' , f re ti It 4..07 El Concrete for fourrlldatl.ans and load bearing "nlabn Is required to be 3000 pal in 20 dayn - UDC Chapter 26. Mortar and grout shall be In accordance with r � UBC Chapter 24 & Table 24 -A and 24 -B. U<) Masonry units, mortar, and grout shall bo protected during cold weather in accordance with UDC Sec. 2404 (c). Concrete shall be protected during cold or hot weather in accordance with UDC Sec. 2605 (f) and (g). 3. Minimum concrete and /or masonry foundation reinforcement requirements are shown on the attachment.. (Notes these minimums apply only if a foundation soils investigation is not performed and the moils are assumed to have an expansion index of 20 or less and footing loads leas than 2000 lbs /linear foot - UBC Sec. 2904 (a) and (b) and Sec. 2906. 4. Foundation frost protection Is 30" from finished grade to top of footing - UDC 2907 (a). Foundations shall extend a min. of 6" above finished grade - UBC 2907 (d). Provide for the control and drainage of surface water away from the building - UBC 2907 (f). 7. Foundation walls enclosing a basement below grade shall be clamp- proofed on the exterior with approved materials - UDC Sec. 1707 (d). - -- 0) Foundation plates or sills shall be redwood or pressure treated wood (UBC - 2516 (c)), and shall be bolted to the foundation with not less than 1/2" dia bolts embedded at least 7" into concrete or masonry, spaced not more than 6 feet apart, min. of 2 bolts per piece and within 12" of each end of piece ' /� - UBC 2907 (1).. 1 �./ Exterior concrete or masonry piers shall extend 0" min. above grade unless the poste or columns which they support are treated or decay resistant wood. Columns and poste located in basements shall be supported by concrete piers or metal pedestals extending 6" min. above earth and 1" min, above floor unless treated or decay resistant wood - UDC Sec. 2516 (c) 4. CD Manufactured trusses, and manufactured joists and beams (1.e. TJI /Micro- Latns, DCI /Versa -Lams, Gln -Lams, etc.), shall be sized and installed in accordance with the manufacturers requirements. 11. Wood joists or floor beams located closer than 10" or wood girders closer than 12" to the ground in crawl spaces shall be treated or decay resistant wood - UDC Sec. 2516 (c) 2. 12. Girders supported by masonry or concrete shall have 1/2" air space at top, sides, and ends tialess treated or decay resistant wood - floc Sec. 2516 (c) 5. Ends of beams' and girdern shall have min. 3" of bearing on masonry or concrete - UDC Sec. 2517 (c). 13. Floor joists under and parallel to bearing partitions shall be doubled UBC 2517 (d) 5. , 14. Floor joists require full. depth solid blocking and must lap a min. of 3" ,� over bearing supports - UDC 2517 (d)'3. l±?..) Beams, roof rafters, and ceiling and floor joists shall be supported laterally in accordance with UBC 2506 (h). 1 070 Columns, posts, beams, and girders shall have positive connection° provided i to ensure against both uplift and lateral displacement - UDC Sec. 2516 (m). 17. Ends of floor joists shall have 1 1/2" min. bearing on wood or metal and no less than 3" on concrete or masonry - UBC Sec. 2517 (c) and (d) 2. le. Notches on the coda of floor joists - max. 1/4 joist depth. pored holes not within 2" of top or bottom of joist and hole diameter no larger than 1/3 depth of joist. Notches at top or bottom shall not exceed 1/6 depth and not located In middle 1/3 span - UBC Sec. 2517 (d) 3. 1. 19. Floor joists and /or roof rafters are insufficient for the span - UBC Table 25 -V -J -1 and UDC Standards. C o) Roof live load (snow load) shall be 40 pef below 7,000 feet elevation -UBC Sec. 2305 (d) -dead loads shall he as required in UDC Sec. 2305. 21. Floor live load shall be 40 psi - UOC Sec.2304 (a) and Table 23 -A -1 - dead loads shall be as required in UnC Sec. 2304. 2 Basie wind speed shall be Bo mph - UDC Sec. 2311. (leaders over wall openings 4' wide or less shall be doubled 2" framing lumber on edge. Over 4' wide the header shall be sized for the span - WIC Sec. 2517 (g) 5. 24. Bearing walls supporting two floor loads are required to be a min. of 3" x 4 "or 2 "x 6" studs with a max. spacing of 16" on center -IIDC Sec. 2517 (g) 1. 25. Wood studs may be cut or notched to a depth not exceeding 25% of width in exterior walls and bearing partitions and not exceeding 40% of width In non- bearing partitions - UDC Sec. 2517 (g) B. 26. Wood studs may have bored holes no greater in diameter than 40% of stud width, 60% of width of doubled studs (but not more than 2 successive doubled studs). Ho holes shall be bored nearer than 5/0" to edge of stud - UOC Sea. 2517 (g) 9. 27 Wall bracing required both sides of each corner and every 25 lineal feet - the braced panel must be a min. of 40" In width perpendicular to studs - UOC Sec. 2517 (g) 3. 20 Approximate min. insulation values are R -19 walla, R -25 roofs, and R - floors over unheated space - Dee frlansi for morn npcol((0 requirements - "Colorado Energy Conservation Standards." 29. Foam plastic insulation shall be separated from the building interior, including attics and crawl spaces, in accordance with 11DC Sec. 1712. Other insulation (including duct and plenum insulation and coverings per UMC Chapter 10) including facings shall meet the requirements of UDC Sec. 1713. 30. Masonry and stone veneer units (5" max. in thickness) shall have min. size of No. 22 gauge by 1" gals. metal ties or'No. 9 gauge gaiv. wire ties and spaced to support not more than 2 sq. ft. of wall area but not more than 24" on center horizontally. When applied over stud construction, the studs shall be max. of 16" on center. Approved building paper must be applied ' over the sheathing or studs - UDC Sec. 3006 (d). 31. Ceiling height is required to be 7'6" In all rooms except kitchens, hallo, bathrooms, and storage areas which may be 7 min. c UDC Sec. 1207 (a). - - - -- 32. Min. stairway headroom clearance is 6'0" - URC Sec. 3306 (p). -- -- 33. Min. stairway width is 36" - UDC Sec. 3306 (b) and min. landing dimension in the direction of travel must also be 36" - UDC Sec. 3306 (g). 34. Stairways m i n ; run 9 "; max. rise 0 "; max. variation in rise and run 3/0" - UBC Sec. 3306 (c). 35. Enclosed usable space under interior and exterior stairways shall be protected on the enclosed side as required for one -hour fire - resistive construction - UDC Sec. 3306 (m). Fire stops shall be provided in accordance with UnC Sec. 2516 (f) 2c. 36. Stairway handrails: min. height 34 "; max. height 30 "; handgrip portion shall be not less than 1 1/2" nor more than 2" in x- section dimension. Min. of one handrail required on all stairways with more than three risers. Hin. 1 1/2" space required between wall and handrail - U11C Sec. 3306 sed 37. Guardrails of 36" min. height shall be installed at unenclo floor openings and open sides of stairways, landings, rampn, decks or porches more than 30" above grade or floor below. Open guardrails shall have a pattern each that a 'sphere 6" in die. cannot pass through - UOC Sec. 1711. 30. Under -floor (crawl apace) cross ventilation is required equal to 1 sq. Et. for each 150 sq. ft. of under -floor area - UDC Sec. 2516 (c) 6. 39. Under -floor areas shall be provided with a min. 10" by 24" access opening - UDC Sec. 2516 (c) 2. 30" by 30" mill. if mechanical equip. in under -floor area - UNC See. 709. 40. All sleeping rooms below the fourth story without a door opening to the exterior shall have at least one operable window that meets the following requirements1 NRIINIIII clear opening: 5.1 eq. Et. MAXIMUM sill heights 44" MINI11111 net clear opening height! 24" (x34 1/4" = 5.7 sq.ft.) MINIMUM net clear opening width: 20" (x41" = 5.7 sq. ft.) Tills also appl.len to basement sleeping rooms - 1IDC Sec. 1204. 41 Glazing In hazardoun locations as defined in UDC Sec. 5406 (glazing in doors and adjacent to doorways, and glazing in windows located within 10" vertically of a walking surface) shall be safety glazed or protected. 42. Glass in sloped glazing (more than 15 from the vertical) and skylights shall meet the requirements of UOC Chapter 34. Skylights and roof and wall panels of light- transmitting plastics shall meet the requirements of UBC Chapter 52. 43. Provide combustion air for fuel burning equipment per 11MC Chapter 6. 44. Pressure relief valves and /or combination pressure /temperature relief valves Shall be provided with a drain line to a floor drain with min. 1" air gap • or extended to the exterior of the building - UPC Sec. 1007. 45. Domestic dishwashing machines shall not be directly connected to a drain or waste disposer without the use of an approved airgap - UPC Sec. 608 (d). 46. Fuel burning appliances shall not be located in any room used or designed to be used as a sleeping room, bathroom, or closet or any enclosed space opening into such room or space UPC Sec. 1309 and UMC Sec. 704 (unless listed for such use). 47. Appliances (including space heating and water heating equipment) shall be accessible for repair and removal in accordance with the UMC. 48. LPG fueled appliances shall not be installed in a pit, under -floor (crawl) space, or basement - UMC Sec. 504 (f). 49. Appliances located in a garage (or in an enclosure opening into a garage) shall be located out of the normal path of vehicles or protected from damage. Any portion of the appliance creating a flame, spark or glow shall be installed a min. of 18" above the garage floor - UMC Sec. 500. 50. Each water closet stool nhall be located in a clear space, not lens than 30" in width and 24" in front of stool - UBC Sec. 511 (a). 51. Toilet rooms without operable windows shall be equipped with an exhaust system ducted to the exterior - IIUC Sec. 1205 (c). 52. Showers and Tub /Shower enclosures shall have a smooth, hard, nonabsorbont surface to a height of 70" min. above the drain inlet - UDC Sec. 510 (b). Water- resistent gypsum board shall not be used over vapor barriers, in ''� saunas or steam rooms, or on ceilings - UDC Sec. 4712. • CD . Attic access opening of not less than 22" by 30" is required - UDC Sec. 3205 (a). 30" by 30" if mechanical equip. In attic space - UMC Sec. 708. 54 Enclosed attic and rafter spaces shall have cross ventilation of min. 1/150 of the area of the space ventilated. The area may be 1/300 if provided equally at lower and upper portions of the space with inin. 3' vertical separation of :locations - UDC Sec. 3205 (c). 5 Garage side of common wall between living apace and garage shall be finished with materials approved for one -hour fire- resistive construction. This also applies to ceilings and bearing walla if living space above the garage: Self closing min. 1 3/8" solid , tight fitting door in required between house and Anrage IIEe 503 (d)'` 3. 56. Electrically wired, interconnected smoke detectors are required in all sleeping room access areas, near the top of stalrwalis in upper levels, and near the bottom of stairways to basements - UDC Sec. 1210 (a). 57. Wood stoves and factory built chimneys, and manufactured fireplace units and venting systems shall be installed in accordance with the manufacturers listing requirements and inspected during installation UMC Chapter 9 and UBC ' Chapter 37. 50. Masonry and concrete fireplaces and barbecues shall meet the requirements of UDC Chapters 23, 24, 26, 27 and 29. A chimney shall not support any structural load other than its own weight unless designed as a supporting member - UDC Sec. 3703 (a).' 59. 60. COPIES OF TIIE ITEM(S) CHECKED DELOW ARE AT'TAC11ED. (Copies of any of the items above or below are 'available upon request). Excavations, fills, foundations, and retaining walls - UDC Chapters 23 and 29. Retaining walls - UDC Sec. 2300 (b) and 2907 (g) j. Roof coverings and drainage - (Inc Chapter 32 (Roof drains sized in accordance with UPC Appendix D). Roof sheathing - (Inc Sec. 2516 (f). Wood combined with (supporting) masonry or concrete - UDC Sec. 2515. Floor sheathing - UDC Sec. 2516 (h). Wiring in plenums - UMC Chapter 10 and NEC. Fire and draft stops - UDC Sec. 2516 (f). Nailing requirements for connecting wood members - UDC Sec. 2516 (j). Enclosure of elevator, vent, and dumbwaiter shafts, and clothes and rubbish chutes - UDC Sec. 1706. Exterior wall coverings and exterior weather protection - UDC Sec. 1707 (d) and 2516 (g). _ Interior application of gypsum wallboard and interior and exterior application of lath and plaster - UDC Chapter 47. Manufactured wall and ceiling covering systems (simulated stucco, etc.) shall be installed in accordance with manufacturers requirements. Landings and floor level at doors - UDC Sec. 3304 (1). Cross connection control and back flow prevention - UPC Sec. 1002 and 1003. Treated Wood Foundation Systems - UBC Standard 29 -3. • INSPECTION WILL NOISE BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT r'‘ AFIELD CO TY, COLORADO. [ Date Issued / _7 Zoned Area rile( b Permit No, 4 ? °' AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from ou j,ilginr,Inspector nd IMMEDIATELY BECOME NULL AND VOl 0, Use S f Addre.s r Legal Descript n / S I 74 ' . ji Owne Setbacks Front Side Side Rear This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection. INSPECTION RECORD Zoning Roof Covering Electric -Final (by STATE inspector) Footing J/, / -J) `/J - .he-, 11 15a ?.57 7 - - -93 3:7,,.. Foundation hnan yViIr Plumbing - Underground Gas Piping I- Ieating Ventilation Frame ( a _ a i 1 d, - )7 Ipulalion Plumbing -Rough Drywall Electric-Rough .4 "1'' (by STATE inspector) -:,Vi Final q_.2,_.? 3 ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING — WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 945 -8212 109 8Ih Street, County Courthouse, Glenwood Springs, Colo. APP O 1 V E D I NOT DESTROY THIS CARD „ i Date 1 to :yek (,y... IF PLACED 0 UTSI E - COVER WITH CLEAR PLASTIC a . •