Loading...
HomeMy WebLinkAbout4748 N 047 GARFIELD COUNTY BUILDING, SANITATION and PLANNING DEPARTMENT 109 8th Street Sults 303 Glenwood Springs, Colorado 81801 (303) 9454212 Granville W. & Glenda L. Farnum , 0101 Van Dorn ltd, Glenwood Springs Job Address NatureofWork Building Permit Use of Building Carport Owner Granville W. & Glenda L. Farnum Contractor Swner Amount of Permit: $ 39.10 Date May 12, 1993 Permit: 54.00 Plan : 35.10 S. Archuleta Clerk White - Treas. Canary-Office Pink - Applicant Gold- Duplicate GARFIELD COUNTY APPLICATION FOR BUILDING PERMIT ��� PERMIT N BEER Assessor's Parcel �f '� please print or type DATE ,4�/�, 57 TO BE FILLED OUT BY APPLICANT PLOT PLAN ADDRESS C)161 Veld bor l- NOTE: Show easements, property line dimensions, SUBDIVISION Che lyyvl /}Cygs all other structures, specify north, and street cl FILING # LhT # BLOCK # name. For odd shaped lots, or if space is a TAX SCHEDULE # 0 Vel 77 too small, provide separate plot plan. LEGAL (SEC /TWN /RNG) # OF BUILDINGS NOW ON PARCEL Q/1 e . Q f el V USE OF BUILDINGS NOW ON PARCEL cG NAM E `7 f4 vl I ! l OW - ), ,r / W MAILING ADDRESS P Q . (3 & y q-((' � (.� / \. 7 �-+ " C C.. o CITY Cl/10 • ./ „ �I PHONE qq9 -7t k(r tl - c,(6,(77._ / f / / NAME r`l �.$ ` 96 o — a w ADDRESS CITY o NAME Q La'r1 f. � . - • Q ADDRESS CITY 'o (PHONE LICENSE # 0 CLASS OF WORK 'JEW ALTERAT,ION ADDITION X DEMOLISH REPAIR _ MOVE MOBILE HOME (make /model) S.F. OF BUILDING S.F. OF LOT # OF FLOORS (HEIGHT ff OF FAMILY UNITS # OF BEDROOMS INTENDED USE OF BUILDING GARAGE: SINGLE DBL CARPORT: SINGLE DBL )<_ FRONT PROPERTY LINE FIREPLACE DOCUMENTS T CU ATTACHED _ STREET NAME /ROAD NUMBER /V WATER SUPPLY CHECK IF CORNER LOT DRIVEWAY PERMIT MA. DESCRIPTION OF WORr PLANNED SITE PLAN , � Ii v l i .._ [ I ' ;'l Epp y V � 2 BUILDING PLANS L. /.-- pX /S f ✓� ,-P s r e YI!' 2 SANITARY SEWER CLEARANCE ,4. I hereby acknowled that I have read this ON SITE SEWAGE DISPOSAL PERMIT A✓4 application and the above is correct and I OTHER DOCUMENTS (specify) agree t9lcomplg ith c y ordinances and st 9 et laws �% tin busldin 9 construction Tit 7 n S r y ' c> C�CV, OF f7 SIGNATURE _i/ FOR OFFICE USE ONLY VALUATION 0 b D. 0 o FLOOD HAZARD PERMIT FEE $ 54,c- CHECK FEE $3S% /0 CERTIFIED BLDG ELEVATION TOTAL FEE $67„ SCHOOL IMPACT FEE $ /WI SPECIAL CONDITIONS DATE PERMIT ISSUED ZONING DISTRICT , - / ^n //� /-� PROBLEMS WITH PERMIT TYPE OF OCCUPANCY Al TYPE OF CONSTRUCTION V- /k./ ADDITIONAL INFORMATION NEEDED S.F. OF BUILDING S.F. OF LOT 3,/9,3¢0,. _ MAX. HEIGHT / L_ ROAD CLASS. CERTIFIED BY COLORADO REGISTERED LAND SURVEYOR SETBACKS FROM PROPERTY LINE: FRONT3p 0HQ cit OR ENGINEER REAR RIGHT LEFT OFF STREET PARKING SPACES REQUIRED �� 7 APPROVED( / . / -� /Ay CT/y 3 APPROVED: Saar 5 1 G1 < 1} , I , ING DEPARTME , ' E PLANNING DEPARTMENT DATE Y t A v p T . • r ti 1 y.. _ . ti _.. / � 019.6] % -t i o i Zr H NI. Ot0 - /. ` "u ( IF MEE���i I i r w : 0 d p w, t m1 , ! } . , 1 I N O, 4Y96 m N TEl rut non. COXBIP°C11O6 , N' �- I X O +RDEN LEVEL Banner M / S_ T :XD PTTPCNED eaRAOE e ° S N w - /-0 P a �'g m ._ TRACT 6 '2 • TRACT ' ' � J.191 AC Y I • ?.' o • IIS._ . • .[ F — : m i r. • Y ✓v`r,! E AST m F . .le0e'... 322.62 y dCGLS6 1SI TRACP 0 pf '� - n Acre° SYEdi vi 9 wM County t . ,' N1'IUt 19, MSY t fcen feet in width r ` ��., eAld aaeewt le n y r ;Ot ON [ollaUin9 d0+c[IE°d Cell ine. .S. *y end of T[ect t end CM1e nartli _e e 1. TRACT IR L� °A T.+ a et corner a[ 0.699 a u[eee Wdt � T Y .c ppv(IIM cM1e [°iloring ro lY'. 6 • I '' f lnt 1 {�'l1 c TIFI -GATE I 'i - M�[ape i 0 e IMPROV FKI LO.CA--1 ' wY M.lwt a`-:. ' TRACT 6 y -.'SA [.at b"' o i'� CHELYN ACRES, GARFIELD COUNTY, CO. • tna Nr sLNt of Ifar °[ ° wbur /' ALSO BEING 1N THE <:',;.•• c ..lcviy O.igf- Ypre., oars � SE 1/4 SW 1/4 OF SECTION 34, / s °." i� i�� T.6S., R.B9 W. OF THE 6th P.M. • •• • r _ 4 / k A i /. a 6a+ . • R I RpRDYEREPT LOCATION CERTIFICATE e[G1Si Ce[e was fJ l P 1 hereby certify that N1° improvement location c r t i icate emenc nGea f I 1 ' fed for Granville W. Vernon d Glenda L. ParnU . has Oean m°n°x • by otlther. an 060 based on a porevl °be property survey the ea 6b1ieeeb Nat f w. f o d that it is not to be t. 11069. 1 further = .tr [ • I i [enc.. building o= future improvements tro=t on this dace, except utility k • I the improvemenzee On the b v a boundaries of the Greet, ee%er x+ - nn a n1Y ,v,[xM1achsehnte�q,on the described pr - y Y I connections e fit there 1 ado eg preoi.e cept as indicates and that + y I improvements n nee ` rni of any "' ex t roeeing orburdening any there � ' - m [ evidence en noted. 0 part of paid 1 except j l c p er-- .. rm n a T b T � — �5 p LEGAL DESCRIPTION MOUNTAIN ENGINE£R/NG xra0t ., chelyn Acree SubdivielM. A part of the SEl /0 of l a LAND SURVEYING CO. e SRI /a =f GLEN W000 SPRINGS, CO. • section ]e. 0ty, South, 6 doU, Pan9e 99 West of the Sixty Principl Re[ldlasection ''� l Garfield Wwty, Colorado. DATE OF SURVEY S JUNE 1950 ry' i4 1 AIE 40 FT. • '4. NL 1 M. - lila Gam- - .'il!� 3 - 2-t /) •�� -- ( � �,, - - - cW ^; j•, ;l > ,[ y / / f <_ _ - ,...:.PERMIT # OWNEIl6i0 � r LOCATION ( Vold y- id CONTRACTOR THE FOLLOWING TEMS MAY HAVE BEEN OMITTED FROM YOUR PLANS OR MAY NOT COMPLY WITH I THE PROVISIONS OF THE UNIFORM BUILDING CODES. PLEASE CHECK ALL CIRCLED ITEMS 1 BEFORE BEGINNI G CONSTRUCTION. ALL REFERENCES ARE 1988 EDITIONS OF THE CODES. THESE ITEMS A,E REQUIREMENTS FOR R -3 OCCUPANCIES ONLY (ONE AND TWO FAMILY DWELLINGS) AND ARE NOT ALL INCLUSIVE OF TILE CODE REQUIREMENTS, BUT ARE MEANT AS A GUIDE TO S ME OF THE MOST OFTEN ENCOUNTERED QUESTIONS RELATED TO CODE REQUIREMENTS. THE APPROVED PLANS RETURNED TO YOU SHALL BE KEPT AT THE BUILDING SITE DURING CO STRUCTION. FOR ANY REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE CONTACT THE CO ORADO ELECTRICAL INSPECTOR. THERE SHALL B A FINAL INSPECTION AND APPROVAL OF ALL BUILDINGS AND STRUCTURES I•IIIEN // /$ ED AND RS Y FM yC ,4ANC AND USE - UBC SEC. 30,5 (d) • - „ �• e1hC /G� `f( / J . JY t McI a / oil off/ �oc�P fe u�fen�eafs eve., i Concrete or fou da i ns a load bearing slab is require to be 3000 psi in 28 day - UBC Chapter 26. Mortar and grout shall be in accordance with UBC Chapt r 24 & Table 24 -A and 24 -B. Masonry u its, mortar, and grout shall be protected during cold weather in s,� a accordant with UBC Sec. 2404 (c). Concrete shall be protected during cold or hot wejather in accordance with UBC Sec. 2605 (f) and (g). .i firc.ICd � (1) Minimum doncrete and /or masonry foundation reinforcement requirements are - Fe lah',,y shown on[the attachment. (Note: these minimums apply only if a foundation assumed to have an LI / ! s soils in estigation is not performed and the soils are expansion index of 20 or less and footing loads less than 2000 lbs /linear foot - UBC Sec. 2904 (a) and (b) and Sec. 2906. Foundaticn frost protection is 30" from finished grade to top of footing - UBC 2907 (a). Foundaticns shall extend a min. of 6" above finished grade - UBC 2907 (d). Provide for the control and drainage of surface water away from the building - UBC 29.7 (f). 7. Foundati•n walls enclosing a basement below grade shall be,damp- proofed on the exte for with approved materials - UBC Sec. 1707 (d)., 8. Foundati•n plates or sills shall be redwood or pressure treated wood (UBC 2516 (c)), and shall be bolted to the foundation with not less than 1/2" dia bolts em.edded at least 7" into concrete or masonry, spaced not more than 6 feet a•art, min. of 2 bolts per piece and within 12" of each end of piece - UBC 29:7 (f). 9. - Exterior concrete or masonry piers shall extend 8" min. above grade unless the post= or columns which they support are treated or decay resistant wood. Columns .nd posts located in basements shall be supported by concrete piers or metal pedestals extending 6" min. above earth and 1" min,: above floor unles heae td or decay resistant wood - UBC Sec. 2516 (c) 4.' 10 Manuf act red trusses, and manufactured joists and beams (i.e. TJI /Micro- Lams, BC: /Versa -Lams, Glu -Lams, etc.), shall be sized and ins in accordan -e with the manufacturers requirements. 11. Wood han 12" to floor in s crawl spaces shall be t wood treated or decay resistant wood - U :C Sec. 2516 (c) 2. 12. Girders - upported by masonry or concrete shall have 1/2" air space at top, sides, a d ends unless treated or decay resistant wood - UBC Sec. 2516 (c) 5. Ends' of beams and girders shall have min. 3" of bearing on masonry or concrete - UBC Sec. 2517 (c). 13. Floor joists under and parallel to bearing partitions shall be doubled UBC 2517 (d) 5. j 14. Floor Jo sts require full depth solid blocking and must lap a min. of 3" over bea ing supports - UBC 2517 (d) 3. ' 0 Beams, oof rafters, and ceiling and floor joists shall be supported laterall in accordance with UBC 2506 (h). 16 Columns, posts, beams, and girders shall have positive connections provided to ensur against both uplift and lateral displacement - UBC c. 2516 (m). 17. Ends of door joists shall have 1 1/2" min. bearing on wood or Se metal and no less tha 3" on concrete or masonry - UBC Sec. 2517 (c) and (d) 2. 18. Notches bn the ends of floor joists - max. 1/4 joist depth. Bored holes not within 2J of top or bottom of joist and hole diameter no larger than 1/3 depth of joist. Notches at top or bottom shall not exceed 1/6 depth and not located in middle 1/3 span - UBC Sec. 2517 (d) 3. [ 19. Floor joists and /or roof rafters are insufficient for the span - UBC Table i 25 -V -J -1 and UBC Standards. - 20 Roof li load (snow load) shall be 40 psf below 7,000 feet elevation -UBC Sec. 23 5 (d) -dead loads shall be as required in UBC Sec. 2305. ( 0 v!V 7 - `f CoPy 21. Floor li e load shall be 40 psf - UBC Sec.2304 (a) and Table 23 -A -1 - dead loads sh 11 be as required in UBC Sec. 2304. Q Basic wi d speed shall be 80 mph - UBC Sec. 2311. 23. Headers ver wall openings 4' wide or less shall be doubled 2" framing lumber o edge. Over 4' wide the header shall be sized for the span - UBC Sec. 251 (g) 5. 24. Bearing alls supporting two floor loads are required to be a min. of 3" x 4 "or 2 "x 6" studs with a max. spacing of 16" on center -UBC Sec. 2517 (g) 1. 25. Wood stu s may be cut or notched to a depth not exceeding 25% of width in exterior walls and bearing partitions and not exceeding 40% of width in non- ., bearing artitions - UBC Sec. 2517 (g) 8. 26. Wood stu s may have bored holes no greater in diameter than 40% of stud width, 6 % of width of doubled studs (but not more than 2 successive doubled studs). No holes shall be bored nearer than 5/8" to edge of stud - UBC Sec. 2517 (g) 9. 27 Wall bra ing required both sides of each corner and every 25 lineal feet - the braced panel must b min. of in width perpendicular to studs - UBC Sec. 251 (g) 3. ,gee /f 6t,M 6. 28. Approxim to min. insula value are R -19 walls, R -25 roofs, and R -11 floors oer unheated space - see plans for more specific requirements - "Colorad Energy Conservation Standards." 29. Foam pl stic insulation shall be separated from the building interior, includin4 attics and crawl spaces, in accordance with UBC ,Sec. 1712. Other insulation (including duct and plenum insulation and coverings per UMC Chapter 0) including facings shall meet the requirements of UBC Sec. 1713. 30. Masonry nd stone veneer units (5" max. in thickness) shall have min. size of No. 2 gauge by 1" galv. metal ties or No. 9 gauge galv. wire ties and spaced t support not more than 2 sq. ft. of wall area but not more than 24" on cents horizontally. When applied over stud construction, the studs shall be max. of 16" on center. Approved building paper must be applied over the sheathing or studs - UBC Sec. 3006 (d). 31. Ceiling eight is required to be 7'6" in all rooms except kitchens, halls, bathroom:, and storage areas which may be 7 min. - UDC Sec. 1207 (a). - -- 32. Min. stairway headroom clearance is 6'8" - UBC Sec. 3306 (p). - -- 33. Min. stairway width is 36" - UBC Sec. 3306 (b) and min. landing dimension in the direction of travel must also be 36" - UBC Sec. 33b6 (g). 34. Stairway. ruin. run 9 "; max. rise 8 "; max. variation in rise and run 3/8" - UBC Sec. 3306 (c). 35. Enclosed usable space under interior and exterior. stairways shall be protecte. on the enclosed side as required for one -hour fire - resistive construc ion - UBC Sec. 3306 (m). Fire stops shall be provided in accordan e with UBC Sec. 2516 (f) 2c. 36. Stairway handrails: min. height 34 "; max. height 38 "; handgrip portion shall be not 1 -ss than 1 1/2" nor more than 2" in x- section dimension. Min. of one handrail required on all stairways with more than three risers. Min. 1 1/2" space required between wall and handrail - UBC Sec. 3306 (j). 37. Guardrai s of 36" min. height shall be installed at unenclosed floor openings and open sides of stairways, landings, ramps, decks or porches more than 30" above grade or floor below. Open guardrails shall have a pattern such tha a sphere 6" in dia. cannot pass through - UBC Sec. 1711. 38. Under -£l•or (crawl space) cross ventilation is required equal to 1 sq. ft. for eac 150 sq. ft. of under -floor area - UBC Sec. 2516 (c) 6. 39. Under - floor areas shall be provided with a min. 18" by 24" access opening - UBC Sec. 2516 (c) 2. 30" by 30" min. if mechanical equip. in under -floor area - C Sec. 709. 40. All sle ping rooms below the fourth story without a door opening to the exterio shall have at least one operable window that meets the following require ents: MINIMUM clear opening: 5.7 sq. ft. MUM sill height: 44" MI IMUM net clear opening height: 24" (x34 1/4" = 5.7 sq.ft.) MI IMUM net clear opening width: 20" (x41" = 5.7 sq. ft.) Th s also applies to basement sleeping rooms - UBC Sec. 1204. 41. Glazing in hazardous locations as defined in UBC Sec. 5406 (glazing in doors and adj cent to doorways, and glazing in windows located within 18" vertica 1y of a walking surface) shall be safety glazed or protected. 42. Glass i, sloped glazing (more than 15 from the vertical) and skylights shall meet the requirements of UBC Chapter 34. Skylights and roof and wall panels of light- transmitting plastics shall meet the requirements of UBC Chapter 52. 43. Provide combustion air for fuel burning equipment per UMC Chapter 6. 44. Pressure relief valves and /or combination pressure /temperature relief valves shall b1 provided with a drain line to a floor drain with min. 1" air gap or extend d to the exterior of the building - UPC Sec. 1007. 45. Domestic ishwashing machines shall not be directly connected to a drain or waste dis oser without the use of an approved airgap - UPC Sec. 608 (d). 46. Fuel burn ng appliances shall not be located in any room used or designed to be used as a sleeping room, bathroom, or closet or any enclosed space opening into such room or space* UPC Sec. 1309 and UMC Sec. 704 (unless listed fot such use). 47. Appliance (including space heating and water heating equipment) shall be accessibl for repair and removal in accordance with the UMC. 48. LPG fuele appliances shall not be installed in a pit, under -floor (crawl) space, or basement - UMC Sec. 504 (f). 49. Appliance located in a garage (or in an enclosure opening into a garage) shall be located out of the normal path of vehicles or protected from damage. ny portion of the appliance creating a flame, spark or glow shall be instal ed a min. of 18" above the garage floor - UMC Sec. 508. 50. Each wate closet stool shall be located in a clear space not less than 30" in width nd 24" in front of stool - UBC Sec. 511 (a). 51. Toilet rooms without operable windows shall be equipped with an exhaust system ducted to the exterior - UBC Sec. 1205 (c). 52. Showers and Tub /Shower enclosures shall have a smooth, hard, nonabsorbent surface t a height of 70" min. above the drain inlet - UBC Sec. 510 (b). Water -res stent gypsum board shall not be used over vapor barriers, in saunas or steam rooms, or on ceilings - UBC Sec. 4712: 53. Attic acc ss opening of not less than 22" by 30" is required - UBC Sec. 3205 (a). 30" y 30" if mechanical equip. in attic space - UMC 'Sec. 708. 54. Enclosed ttic and rafter spaces shall have cross ventilation of min. 1 /150 of the a ea of the space ventilated. The area may be 1/300 if provided equally t lower and upper portions of the space with min. 3' vertical separatio of locations - UBC Sec. 3205 (c). 55. Garage ai a of common wall between living space and garage shall be finished with mate ials approved for one -hour fire - resistive construction. This also applies o ceilings and bearing walls if living space above the garage. Self closing min. 1 3/8" solid , tight fitting door is required between house and garage UBC 503 (d) 3. 56. Electrically wired, interconnected smoke detectors are required in all sleeping room access areas, near the top of stairways in upper levels, and near the bottom of stairways to basements - UDC Sec. 1210 (a). 57. Wood stoves and factory built chimneys, and manufactured fireplace units and venting systems shall be installed in accordance with the manufacturers listing requirements and inspected during installation UMC Chapter 9 and UBC Chapter 7. 58. Masonry nd concrete fireplaces and barbecues shall meet the requirements of UBC Chapters 23, 24, 26, 27 and 29. A chimney shall not support any structural load other than its own weight unless designed an a supporting member - UBC Sec. 3703 (a). 59. 60. COPIES OF THE I ITEM(S) CHECKED BELOW ARE ATTACHED (Copies of any of the items above or belox are available upon request). Excavaticns, fills, foundations, and retaining walls - UBC Chapters 23 and 29. Retaining walls - UBC Sec. 2308 (b) and 2907 (g) 4. (y) li Roof coverings and drainage - UBC Chapt 2 (Roof drains sized in accordancqe with UPC Appendix D).,Ib /Q P/- /)[(( f'rciifeN rim f ' Roof she thing - UBC Sec. 2516 (i). Wood combined with (supporting) masonry or concrete - UBC Sec. 2515. Floor shathing - UBC Sec. 2516 (h). Wiring i plenums - UMC Chapter 10 and NEC. Fire and draft stops - UBC Sec. 2516 (f). Nailing equirements for connecting wood members - UBC Sec. 2516 (j). Enclosure of elevator, vent, and dumbwaiter shafts, and clothes and rubbish chutes - UBC Sec. 1706. Exterior wall coverings and exterior weather protection - UBC Sec. 1707 (d) and 2516 (g). Interior application of gypsum wallboard and interior and exterior applicatton of lath and plaster - UBC Chapter 47. Manufactured wall and ceiling covering systems (simulated stucco, etc.) shall be installed in accordance with manufacturers requirements. Landings and floor level at doors - UBC Sec. 3304 (i). Cross connection control and back flow prevention - UPC Sec. 1002 and 1003. Treated Wood Foundation Systems - UBC Standard 29 -3. , !e de u /Tin Roof g n y eta et / lx8 Sheathing 16" U C • 14 , x 26 T 3-1 - 4 -12 Pitch House 4 4x12 Beam 1S ` 4x4 Redwood aG v 7' U 24' } rl2 k_18,,41 k_8„ n R. Wall 1< 32' A R.Wall • 7' 7' 1 2 Rehr __ I I 31 Underground — 8" I- 8" Footer l< 18 " - ->1 r BUILDING PERMIT G RFFIELD COUNT , COLORADO Date Issues /At.. _ Area a AD ' Permit No AGREE ENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and constru ion of the above described structure, the permit may then be revoked by notice from e Co Ily • ui Ind , r id IMMEDIATELY BECOME NULL AND VOID, Use A G Address pr Legal Descriip I / r , ky �, W 0 Mr R e �Gb,M, g 1)0) odes" Setbacks Front Side Side Rear This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection. INSPECTION RECORD Zoning Roof Covering ,. Footing I' -0nn'dalion ��A" 2,7%,4 Z,„ MASTER PLUPII3CR'9 LICF.NSli i1 Plumbing - Underground Gas Piping, [leafing Ventilation Frame . 4' ^/ 7^ T3 9 ='\"" Insulation Plumbing -Rough Drywall Final ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING — WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE ('hone 945 -8212 1119 8111 Street, Comity Courthouse, Glenwood Springs, Colo. APP OVE / a° Y //- Dates„ . B IF PLACED OUTSIDE - COVER WITH CLEAR PLASTIC