Loading...
HomeMy WebLinkAbout5273 I v f No. 5273 GARP7RI 1) COUNTY BUILDING, SANITA77ON and PLANNING DEPARTMENT 109 Sth Slrc t Suite 303 Glenwood Springs, Colorado 81601 (303) 995-8212 Job Address 0146 County Road 105, Carbondale Nature of Work Building Permit Use of Building Remodel Owner Robert C. & Betty Lou Schenck Sr. Contractor Owner Amount of Permit 178.20 Date August 29, 1994 Permit: 108.00 Plan : 70.20 Paid $178.20 8 -11 -94 S. Archuleta Clerk . GARFIELD COUNTY APPLICATION FOR BUILDING PERMIT �� / 1 PERMIT NUMBER o 1 / please print or type DATE S Assessor's Parcel # TO BE FILLED OUT BY APPLICANT PLOT PLAN ADDRESS 04 - /0,,Sel, NOTE: Show easements, property line dimension: SUBDIVISION ,V,Q all other structures, specify north, and street FILING # LOT ,k BLOCK # name. For odd shaped lots, or if space is a TAX SCHEDULE # - too small, provide separate plot plan. LEGAL (SEC /TWN /RNG) # OF BUILDINGS NOW ON PARCEL W NAME — rr USE OF BUILDINGS NOW ON PARCEL % • Y- 892/ , • Je jj � -- MAILING ADDRESS /',559, - - /OS,9,/ ' - p CITY ____ _ PHONE W3 7 m x NAME ,5 e rne - &CIJ,tr /Z r.5cN e w ADDRESS CITY 1,36c. S m NAME � —.. ...._.._._ _.........1 .__...._ o OGeJ.sYF/.� c+ .SON ADDRESS y , N � g CITY _ , P 1 x °HONE LICENSE l,� �� I CJ �, �� / CLASS OF WORK L _, __ ,os NEW : ALTERATION 1./ - "' - " -- /v DEMOLISH REPAIR f MOVE _ 7-- 49.9/Z-e-�S MOBILE HOME (make /model) S.F. OF BUILDING 599' S.F. OF LOT /3,d # OF FLOORS / HEIGHT /g 677fa�QG /7 #, OF FAMILY UNITS / # OF BEDROOMS / INTENDED USE OF BUILDING /51;772 .22,F AZ &Pa , 4.QP,e /N6 K f/A//E GARAGE: SINGLE DBg,/eXCERPORT: SINGLE DBL (jttht ..5//{ /C,E /67 FIREPLACE , /Agl"r FRONT PROPERTY LINE /ran o .siii/.F ,,��ivv� DOCUMENTS ATTACHED _ STREET NAME /ROAD NUMBER /1 WATER SUPPLY //JELL CHECK IF CORNER LOT _ DRIVEWAY PERMIT hl/J DESCRIPTION OF WORK PLANNED SITE PLAN ,(/i2 I BUILDING PLANS ler SANITARY SEWER CLEARANCE . -,E,r,U /NG- I hereby acknowledge that I have read this ON SITE SEWAGE DISPOSAL PERMIT ',era _,G X /Sy" / application and the above is correct and I OTHER DOCUMENTS (specify) agree to comply with all county ordinances ':SPEC and state laws regulat'ng building constructio_ i . ar ,1OB. a ' a P� b, 6[O ' p I n n � 7/ SIG ATURE ' D l "'I lJ� / Y FOR OFFICE USE ONLY VALUATION I " Odd — FLOOD HAZARD PERMIT FEE gag, -' PLAN CHECK FEE $ 7c, 2c-' CERTIFIED BLDG ELEVATION TOTAL FEE $ /78.20 SCHOOL IMPACT FEE $ 007 SPECIAL CONDITIONS 0A /LI/ 46.E H el/L/I�{ h DATE PERMIT ISSUED X6 1J$.EG - V -r Oat, _ ZONING DISTRICT PROBLEMS WITH PERMIT ' TYPE OF OCCUPANCY R ' 3 TYPE OF CONSTRUCTION. r ADDITIONAL INFORMATION NEEDED S.F. OF BUILDING L TT LL''pry' � l d� MAX. HEIGHT RO , CLASS. CERTIFIED BY COLORADO REGISTERED LAND SURVEYOR SETBACKS FROM PROPERTY LINE: FRONT OR ENGINEER REAR RIGHT LEFT OFF STREET PARKING SPACES REQUIRED y pL� `yam P 9/2 �n f APPROVED / L /L/ �/L,_����+7 1 % /� APPROVED: / Y • v 2 Yr B LDING D PAR/ T DATE PLANNING D PARTMENT DATE • GARFIELD COUNTY BUILDING AND PLANNING NOTICE A COPY OF THIS PLAN REVIEW IS ATTACHED TO THE OWNER'S OR CONTRACTOR'S COPY OF THE APPROVED PLANS. THIS PLAN REVIEW IS PROVIDED IN CONJUNCTION WITH OR IN PLACE OF REDLINING THE APPROVED PLAN. IT IS THE RESPONSIBILITY OF THE OWNER AND /OR THE CONTRACTOR TO CLOSELY REVIEW THE PLAN REVIEW AND VERIFY THAT ALL CORRECTIONS NOTED ARE BROUGHT INTO COMPLIANCE WITH CODES ADOPTED BY GARFIELD COUNTY. THE ISSUANCE OR GRANTING OF A PERMIT OR APPROVAL OF PLANS, SPECIFICATIONS AND COMPUTATIONS SHALL NOT BE CONSTRUED TO BE A PERMIT FOR, OR AN APPROVAL OF, ANY VIOLATION OF ANY OF THE PROVISIONS OF ANY CODE, ORDINANCE OR RESOLUTION OF GARFIELD COUNTY. PERMITS PRESUMING TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF CONSTRUCTION CODES OR OTHER ORDINANCES OR RESOLUTIONS OF GARFIELD COUNTY SHALL NOT BE VALID. THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE CHIEF BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA, OR FROM PREVENTING BUILDING OPERATIONS BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF CODES, ORDINANCES OR RESOLUTIONS OF GARFIELD COUNTY. (Authority under the 1988 Uniform Building Code Section 303 (c). titled: Validity of Permit.) THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS OMISSIONS OR DISCREPANCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER, BUILDER AND OWNER. COMMENTS AND NOTATIONS ARE INTENDED TO CONSTRUCTIVE AND IN SUPPORT OF THE OWNERS INTEREST. L a t trhi_w i ti r Art Hougland, of Building Official PRNOTICE 109 8TH STREET, SUITE 303 • 945.82121625- 55711285 -7972 • GLENWOOD SPRINGS, COLORADO 81601 PLANS EXAMINATION August 24, 1994 Robert and Betty Schanck 0146 105 Road Carbondale, CO 81623 #91 -94 This plan review represents an examination of plans / drawings showing substantial conformity with applicable codes of the Garfield County Building Dept. Subject to the following conditions. Respectfully, �y y ,{1) William D Allred LC.B.O., Code Consultant (303) 945-4418 PLAN REVIEW: # 91 GARFIELD COUNTY DATE: PERMIT NO: August 24, 1994 Pi _ANS EXAMINATION ADDRESS: 0146 105 Road Carbondale, CO i1 EB; Ca MUDD& NAME:Robert and Betty Schenck NAME: Owner MAILING ADDRESS: same as above MAILING ADDRESS: TELEPHONE: (303) 963 -2167 TELEPHONE: (303) HI BIDING PERMIT FFI.; Fees are based on the March - April 1994 edition of the Building Standards. Calculated Total Valuation: $9,000.00 Building Permit Fee: = $117.00 Plan Review @ 65 %: _ $ 76.05 Total Fees: $193.06 ELECTRICAL PERMITS MUST BE OBTAINED SEPARATELY FROM THE STATE ELECTRICAL INSPECTOR THIS PERMIT DOES NOT INCLUDE ELECTRIC. Independent Professional Building Inspection Bill Allred 45855 Hwy 6, Canyon Creek # 63 Glenwood Springs, CO 81601 (303) 945-4418 August 24, 1994 Robert and Betty Schenck 0146 105 Road Carbondale, CO 81623 CONDITIONS FOR PLAN REVIEW #91 -94 GENERAL REOIIIREMENTS: 0 -1 All references are taken from the 1988 Uniform Building Code (U.B.C.), 1988 Uniform Plumbing Code (U.P.C.), and the 1988 Uniform Mechanical Code (U.M.C.) Minimum requirements based on Chapter 12., of the U.B.C. The Garfield County Building Official, may require section drawings concerning the structural integrity of the building (foundation, rafter system, bearing walls, etc. (Section 302 (b)., U.B.C.) G -9 It is our understanding that the owner desires to construct the house for himself and therefore does not need a general contractor. However, it is the duty of the owner to notify the Building Dept. when the construction is ready for inspection. Schedule the inspection at least one day before such inspection. All work is subject to inspection prior to any cover up, (Section 305, entire Section of the U.B.C.) BUILDING CODE ITEMS: B -18 Showers shall be finished and sealed to protect structural elements from moisture to a height of not least than 70 inches above the drain inlet, (Section 510 (b)., U.B.C.) Gypsum water resistant green board required, check U.B.C. Standards. B -20 The contractor needs to be aware of (Section 1204 of the U.B.C.), when ordering windows. Each sleeping room shall have at least one window or door which may be used for escape or rescue. The following. required: Maximum sill height above floor: 44 inches Minimum net clear opening width: 20 inches " " 11 height: 24 inches " " 5.7 square feet A minimum of 20 inches wide by 41 inches high or 34 inches wide by 24 inches high is needed to achieve the required 5.7 square feet. B -27 Vent fans are required in each bathroom, note the laundry room is also required to have ventilation capable of providing five air changes per hour and connected directly to the outside, (Section 1205 (c)., U.B.C.). B -37 Exterior roof sheathing and wall sheathing are to be covered with a weather resistive barrier ahead of siding and roof covering. ( Building paper such as 30# felt on the roof sheathing and 15# felt or tyvek, is acceptable on wall sheathing.) (Reference Section 1707 (a) and Chapter 32, of the U.B.C.) B -39 Guardrails of 36 inches minimum height shall be installed at open sides of stairways, landings, ramps, decks, or porches more than 30 inches above grade or floor below. Open guardrails shall have a pattern such that a sphere 6 inches in diameter cannot pass through, (Section 1711, U.B.C.) B -89 The 1988 U.B.C. (Section 3304 (i).,) requires a landing on each side of a door, there are some exceptions. However, the exterior doors are required to have landings. Minimum size 36 inches by 36 inches, provided the door does not swing over the landing, a 7 1/2 inch step is allowed. - B -98 If a wood stove is desired, will need to be an approved stove and be installed according to the manufactures documents and listed and approved by, (LC.B.O., B.O.C.A., or U.L.) B -1.1 Factory built chimney and fireplaces shall be listed and installed in accordance with the manufactures documents and Chapter 37., of the U.B.C., coordinate inspections with the Building Inspector prior to cover -up. PLUMBING CODE ITEMS: P -1 Coordinate all water and sewer extensions, connections, and pressure tests outside the building with the Building Inspector for Garfield County, prior to back fill, (Section 317 (a), (b), (c), (d), of the U.P.C.) P -3 Plumbing and mechanical must comply with the Uniform Plumbing Code (U.P.C.) and the Uniform Mechanical Code (U.M.C.) P4 Dishwashers must hook to the drainage system through an approved air gap. Contact Building Department, for other approved method prior to installation, (Section 608 (c), U.P.C.) P -6 Hose bibbs shall be equipped with self - draining approved backflow prevention devices, (Section 1003 (h) and (i) U.P.C.) P -9 Provide a floor drain for the temperature / pressure relief valves on the boiler and hot water heater. This floor drain needs to be accessible and close to the boiler and hot water heater, (Section 1007, U.P.C.) MECHANICAL CODE ITEMS: M -2 The clothes dryer vent cannot terminate in the crawl space. Will need to be a minimum 4 inch diameter and duct directly to the outside, (Section 1903 (a)., (b)., (c)., of the U.M.C.) G -1.1 Every attempt is made by the Building Department to perform a thorough plan review, however please be aware of (Section 303 (c) of the U.B.C., which states): This issuance or granting of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. The issuance of the permit based upon plans, specifications and other data shall not prevent the Building Official from thereafter requiring the correct- ion of errors in said plans, specifications and other data, or from preventing building operations being carried on thereunder when in violation of this code or of any other ordinances of this jurisdiction. All construction shall be approved prior to the issuance of Certificate of Occupancy P.\ vcil Cif Art Hougland, Bill Allred, (Building Official) (Plan Checker) Garfield County (303) 945 -4418 - • ' 1 ( Lt ill. 7" 73 OVED vpo, cop-0,frotwe ai ri P / /fret, .; 0 NOTED 14../ rm et 09/- ,er. i 5 R my • i..”4.; ; giait/ le IV . . SCS .11 K vi it ROUT IHEit: 1.ANS ON SITE COVPrY oPY' Page y N N 1 F 1 j 1 N I i I , , 5:: l ' 1 1 a I r - �� � f m m tO l`I1 Q J] l H .p 4 ° '6 u csl x P is V 2 • s. M b W 0 Co za tb ck• o r ___ . - _ i 1 g , • . ..... cri 1 J L is T b 1 In ■3\ Q X ? CI U •7 j z 1 A , Vs p J -� .11x N ° w Q - 15, -s r `f S 1W' s 1.3 (.1; �� v a • T V is V _ :: ' , + vs =la'4 I6rt, . . I. . • m 7 -c ,x„.4c --- : 4_1,1c/1'6 rersg/Ilh Ciagzr., A; /re& ^,),/ 25fr7tV 1.4% •/(SL- 4 7. 4AZIL - 2 - /:, /er n ./ , "v ia/7 :V /6 " 2;1; c7t6 - A14/2..L-To 7-.42 /VD. //;, C.t../is/s- Yor4 aoc-f-x •'115 10/ 7; !,, Xt 7Jjo Z., / /cr v 4...)/.77 /2. x-/E-4 • i tior9E/7/6:- ...5. =IL./ .//t 7 4.-) 45'o , . 1 L a40 ...4 . / e " L5 rip o ^ S.c,v0 I Ate F.1- :Ix" r. X 39' ,v i.i„fr. T __:.:. ki 5 3s� l -807; Do , 3,, ,,,,, , 2&z. 4) /'Wa&J 283.5" zg3 .s•. w/yne� �yb'. \\/ r if 93/y 1l 1. z9 '� (j�j 14---- `l z 3!Y < l39 "---- ---- a .1 �7 W/NUOu �1 � 3D „ L z7 a "E — � 99 i / 7, s' 11 ,r v f +' / COLORADO STATE ELECTRICAL BOARD ,,' INSPECTION REPORT AND CORRECTION NOTICE Permit# °7 q y I K 7 y 7 Contractor /Ho> owner " ' ` � J � . �yy Address 0 O 6. f-C . /G..0 wJ ( C r < a> c r . _k_ .c � --c.l Phone # / / (- 7 / Date Received . �� , Date Inspected / � � Arrival Time Consult Time Travel Time Inspection Time Time Lapse TYPE OF INSPECTION: Res. Id'Comm 0 Rough -in 0 Final 0' Partial 0 Reins 0 Temp Meter 0 Temp Heat 0 Mobile Horne 0 Service 0 Other (please specify) v P _ . “,[ r - .l rj Serv t--' Wiring Method �'' Type 1 0 or 3 0 Classified area Yes No v Size /j 7t) GFCI Yes , <Clo Overhead Finished basm't Yes - No Underground .- Sub panels Yes ��No Type Grnd (- Elec Range - Yes � No .�� Size Grnd Conductor - Elec Dryer Yes ''� o Date Meter Released / Elec Wtr Heater Yes No ACTION: Accepted Z _' Rejected Remarks REINSPECTION FEE REQUIRED. -A reinspection will not be per- formed until the reinspection fee is received. You are required to make the following corrections or repairs on the elec- trical installation at the above address. CORRECTIONS: . i 1 Inspector -- I L— e7 f'rQ Page 1 of SALL THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT GARFIELD COUNTY, COLORADO Date Issued 9 Zoned Area Permit No 7 AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above escribed structure, the permit may then be revoked by notice from " unt } B + � uil n sp ector and IMMEDIATELY BECOME NULL AND VOID Use _ [J Addres Lebal Desc 'ption OiV % a 1Q to f C tea 1 " Owner D S.' �" h ' C Contractor t » Setbacks Front Side Side Rear This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection. INSPECTION RECORD Zoning Roof Covering Electric -Final (by STATE inspector) Footing 7/ ; r- q Foundation Plumbing-Underground Gas Piping s s - Heating Ventilation Frame j - yi Insulation / _ / _ Plumhin� Rquhr/ �G f Drywall //- - /' j Electric -Rough b STATE ins etctor s/,. � Y P ) '�� Final i /-n3 -rte ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 945 -8212 10 9 8th Street, County Courthouse, Glenwood Springs, Colo. APPROVED DO NOT DESTROY THIS CARD Date Cl/+^z ? r