HomeMy WebLinkAbout5553 •
•
1 N 5553
GARFIELD COUNTY
BUILDING, SANI7A 77ONand PLANNING DEPARTMENT
109 Sth Street Suite 303
Glenwood Sprioga, Colorado 81601
(303) 945-8212
Job Address 5320 County Road 154, Glenwood Springs
NaturcofWork Building Permit
UscofBuilding Office & Shop
Owner C & C Properties
Contractor Owner
Amount of Permit $ 193.05 - Date June 9, 1995
Permit: 117.00
Plan . 76.05
Paid $76.05 6 -2 -95
S. Archuleta
Clerk
■
cot 6 K2 ¶ys C 7 C
BAJILDING PERMIT APPLICATION C j JgcKSOr wo /hr's.
^ GARFIELD COUNTY, COLORADO
Applicant to complete numbered spaces only. PERMIT NO. CS PARCEUSCHED NO.
JoaAOEREss 3 aQ C O-C- [ 4 /S 5' £4w ce'c iLciren, /f
1 LEGAL LOT NO. BLOCK SUBDIVISION v56d177.nr /yJe- ar�d�2ta4
DESCR, , y ls eT o
2 OWNER C "lc Meer I /e.. ADDRESS 7/70 ts , fl . P ✓ + y { JIIK. PH. S6yrc-c,
3 CONTRACTOR / A ADDRESS PH. LICENSE NO.
4 ARCHITECT OR DESIGNER // ADDRESS PH LICENSE NO
5 ENGINEER Ai ADDRESS
PI1. LICENSE NO. /
6 S.F OF BUILDING {J. Q G $ Al S.F OF LOT /3� rJ de Sp / -, HEIGHT / NO. OF FLOORS l
7 USE OF BUILDING d ir( Si e" p/0
8 CLASS OF WORK: °NEW °ADDITION r$ TERATION &E °MOVE °REMOVE
g DESCnIDE WORK: r,7 /a-rye S / / ��'fP 4'C✓ TGS� /ed i dicArccs #'/eX ri? G4_,, /. // r
doc' f • cOC.- /eel Cale- 1 C/Co'/, arsta4L r.e.- >ef . fAce -/N /e.m/v., f 7
10 GARAGE SINGLE DOUBLE CARPORT SINGLE DOUBLE
DRIVEWAY PERMIT ON SITE SEWAGE DISPOSAL PERMIT SITE PLAN
`
11 VALUATION or WORK: $ /4,erdC f ADJUSTEDVAL.S PLAN CHECK FEE 0 5 PERMIT FEE // C"
SPECIAL CONDITIONS: AlyyGec/ IcYYJt'ovC•i sl/C /l� for •,47tz /fie SCHOOL IMPACT FEE "07 NO. OP BUILDINGS ON USE OF BUILDINGS NOW ON
Q I/ 1 PARCEL PARCEL
/
TOTAL FEE • 3. 5 • OCC. GRQ- Z C TYPE r
NOTICE WATER SUPPLY DATE PERMIT ISSUED 6 -7 -/ S
SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING,
VENTILATING OR AIR CONDITIONING. /
SPECIAL APPROVALS REWIRED RECEIVED Nor REQUIRED
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS ZONIING y
NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED
OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS
COMMENCED. HEALTH DEPT.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW
THE SAME TO SE TRUE AND CORRECT. ALL PROVISIONS of LAWS AND ORDINANCES FIRE DEPT.
GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED
HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE SOIL REPORT
AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR
LOCAL LAW REGULATI> CONSTRUCTION OR THE PERFORMANCE OF SETBACKS
CONST• _ __20N. . - s _
t
• . " - �'1f/NL_' D...4 . ' •. S
air FLOOD FWARD
Sign. . „ a •irontraelor "zee) ir r n. lndl�rs[o notice above —
4 ,.v .M . � r�d� MANUF, HOME
tiding Dela:U �% •ro data. if' Planning Department Approval/dale
`
OTHER
AGREEMENT
PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND /OR THE AGENT OF THE CONTRACTOR OR OWNER TO
CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT
IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE
REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER
AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF
THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT
SHALL BECOME NULL AND VOID.
THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM
THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING
OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS
JURISDICTION.
THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN
ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE
RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER,
BUILDER AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST.
Garform.003 I HEREBY ACKNOWLEDGE THAT 1 HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE IN IAL C
9d ' 2G.DS 6 -a -13 II
GARFIELD COUNTY
BUILDING AND PLANNING
NOTICE
A COPY OF THIS PLAN REVIEW IS ATTACHED TO THE OWNER'S OR
CONTRACTOR'S COPY OF THE APPROVED PLANS. THIS PLAN REVIEW IS
PROVIDED IN CONJUNCTION WITH OR IN PLACE OF REDLINING THE
APPROVED PLAN.
IT IS THE RESPONSIBILITY OF THE OWNER AND /OR THE CONTRACTOR TO
CLOSELY REVIEW THE PLAN REVIEW AND VERIFY THAT ALL CORRECTIONS
NOTED ARE BROUGHT INTO COMPLIANCE WITH CODES ADOPTED BY
GARFIELD COUNTY.
THE ISSUANCE OR GRANTING OF A PERMIT OR APPROVAL OF PLANS,
SPECIFICATIONS AND COMPUTATIONS SHALL NOT BE CONSTRUED TO BE A
PERMIT FOR, OR AN APPROVAL OF, ANY VIOLATION OF ANY OF THE
PROVISIONS OF ANY CODE, ORDINANCE OR RESOLUTION OF GARFIELD
COUNTY. PERMITS PRESUMING TO GIVE AUTHORITY TO VIOLATE OR
CANCEL THE PROVISIONS OF CONSTRUCTION CODES OR OTHER
ORDINANCES OR RESOLUTIONS OF GARFIELD COUNTY SHALL NOT BE VALID.
THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND
OTHER DATA SHALL NOT PREVENT THE CHIEF BUILDING OFFICIAL FROM
THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS,
SPECIFICATIONS AND OTHER DATA, OR FROM PREVENTING BUILDING
OPERATIONS BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF
CODES, ORDINANCES OR RESOLUTIONS OF GARFIELD COUNTY.
(Authority under the 1988 Uniform Building Code Section 303 (c). titled:
Validity of Permit.)
THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND
INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN
ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD
COUNTY FOR ERRORS OMISSIONS OR DISCREPANCIES. THE RESPONSIBILITY
FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS
SPECIFICALLY WITH THE ARCHITECT, DESIGNER U LDER AND OWNER.
COMMENTS AND NOTATIONS ARE INTENDED"TO C NSTRUCTIVE AND IN
SUPPORT OF THE OWNERS INTEREST.
Art Hougland, of Building Official
PRNOTICE
109 8TH STREET, SUITE 303 • 945 8212/625- 5571/285 -7972 • GLENWOOD SPRINGS, COLORADO 81601
CIF.1r.rn NAI. UPON
n ny„ r n
kk.4' ; 114 PA'
noTgo
INSPECTIONS
0 C enotrerfre'
CCiriPti
wrowUr
Or.f4 CP0(1/177
Pago ,
• COlr
•
Garfield County
Building & Planning Department
109 Eighth Street, Suite 303
Glenwood Springs, CO 81601
(303) 945 -8212
Plan analysis based on
the 1988 Uniform Building Code
Project Number: Name: C & C Properties
Address: 5320 County Road 154, near Glenwood SP. Date: June 7, 1995
Contractor: Same
Occupancy: B2 Designer: Same
Type of Const: V -N Engineer: None indicated
Plans Examiner: Art Hougland
NOTE:The code items listed in this report are not intended to be a complete
listing of all possible code requirements in the 1988 UBC. It is a guide to
selected sections of the code.
Report created using Plan Analyst software by b w & a. (719) 599 -5622
Portions of the material contained in this program are reproduced from the
Uniform Building Code ( 1988 edition) with permission of International
Conference of Building Officials
FL NAME OCC MAX FLR AREA ALLOWED RATIO STATUS
1 Office B2 ok 288 Interior finish only
1 Showroom B2 ok 312 Interior finish only
1 Bathroom B2 ok 30 Interior finish only
1 Warehouse B2 ok 480 Interior finish only
1 Warehouse B2 ok 640 Interior finish only
1 Accessory areas B2 ok 90 Interior finish only
TOTAL FOR FLOOR 1840 Allowed area not checked
BUILDING TOTAL 1840 Allowed area not checked
Page # 2
Code review for:
Project Id.: C & C Properties
Address: 5320 County Road 154, near Glenwood SP.
OTHER BUILDING ELEMENTS Table 17 -A
ELEMENT MATERIAL RATING NOTES
Interior Bearing wall Any 0 hr
Interior nonbrg wall Any 0 hr
Structural Frame Any 0 hr
Exterior Struct Frame Any 0 hr See footnote #1
Floor /Ceiling Assembly Any 0 hr
Roof /Ceiling Assembly Any 0 hr
Stairs Any None
FOOTNOTES:
1) Minimum on exterior side also based on exterior brg. wall requirements.
DRAFT STOPS:
If there is combustible construction in the roof /ceiling assembly, draft
stops shall be installed so that the area of concealed space does not
exceed 3000 square feet and so that the horizontal dimension between stops
does not exceed 60 feet. -- Sec. 2516.(f)4.B.(iii)
OCCUPANCY SEPARATIONS
None required
ADDITIONAL SEPARATIONS
FOR B2 OCCUPANCY:
A lhr occupancy separation is required around rooms containing a boiler or
central heating unit greater than 400,000 BTU input. -- Sec. 708.
Storage areas in excess of 1000 sq.ft. are required to be separated from
the retail area by a lhr occupancy separation. -- Sec. 702.(b)2.
EXIT REQUIREMENTS:
FL NAME OCCUPANT NUMBER EXIT PANIC RATED DOOR NOTES
LOAD REQUIRED WIDTH [ft.] HDWR CORRIDOR SWING
1 Office 3 1 0.1 No No N/R
1 Showroom 10 1 0.2 No No N/R
1 Bathroom * 0 1 0.0 No No N/R
1 Warehouse 1 1 0.0 No No N/R
1 Warehouse 1 1 0.0 No No N/R
1 Accessory areas * 1 1 0.0 No No N/R
TOTAL 15 1( 1) 0.3( 0.3) No No N/R
Page # 3
Code review for:
Project Id.: C & C Properties
Address: 5320 County Road 154, near Glenwood SP.
* NOTE: This area is being treated as an accessory for occupant loads.
-- Sec. 3302.(a) exception
Door swing is based on Sec. 3304.(b) except as noted.
Occupant load is based on Table 33 -A.
Number of exits is based on Table 33 -A except as noted.
Exit width is based on Sec. 3303.(b).
FOOTNOTES:
HANDICAPPED ACCESS:
1) Handicapped access is required to at least one primary entrance
to this building. -- Sec. 3301.(e) & Table 33 -A
2) If a ramp is used for handicapped access, the max slope is
1:12. -- Sec 3307.(c)
Provide a landing within 1 inch (1/2 inch at doors used for handicap access)
of the threshold. -- Sec. 3304.(h)
The minimum width is same as door width and the minimum length is 44 inches.
- - Sec. 3304.(i)
The maximum travel distance in this building is 150 feet.
- - Sec. 3303.(d)
AUTOMATIC. SPRINKLER SYSTEMS:
If openings are not provided in each 50 feet of exterior wall or there is
floor area more than 75 feet from an exterior opening, an automatic
sprinkler system is required. -- Sec. 3802.(b)
If there are 100 or more sprinklers, the automatic sprinkler system shall be
supervised by an approved central, proprietary, or remote station service
or a local alarm which will give an audible signal at a constantly
attended location. -- Sec. 3803.
STANDPIPE REQUIREMENTS:
There is no requirement for a standpipe. -- Table 38-A
A hose is not required. -- Table 38 -A
FOOTNOTES:
1) The location is to be per Sec. 3805.(c),(d),and /or(e)
Page # 4
Code review for:
Project Id.: C & C Properties
Address: 5320 County Road 154, near Glenwood SP.
WALL AND CEILING FINISH:
1) Wall and ceiling finish materials are required to comply with
Sec. 4204.(a) and Table 42 -B.
2) Carpeting on the ceiling is required to have a Class I flame
spread rating. -- Sec. 4204.(b)
3) Textile wall coverings shall have Class I flame spread rating.
and shall be protected by automatic sprinklers or meet the
acceptance criteria of U.B.C. Standard No. 42 -2 -- Sec. 4205.
INSULATION NOTES:
1) All insulation material including facings are required to have a flame -
spread rating of 25 or less and a maximum smoke density of 450 unless
it is in a concealed space and the facing is in contact with a wall or
ceiling. -- Sec. 1713.(c) exc. #2
2) Foam plastic insulations are required to be protected. -- Sec. 1712.
GLAZING REQUIREMENTS:
1) All glazing in hazardous locations is required to be of safety
glazing material. -- Sec. 5406.(d)
ADDITIONAL REQUIREMENTS:
For B2 occupancy
In all areas customarily occupied by humans, provide natural or
artificial light and ventilation. -- Sec. 705.
C07
o
•
Page # 5
Code review for:
Project Id.: C & C Properties
Address: 5320 County Road 154, near Glenwood SP.
If water fountains are provided, one must have a spout within 33 inches of
the floor and up -front controls. -- Sec. 511.(c)
HANDICAPPED TOILET FACILITIES:
1) All doorways leading to a toilet room for handicapped are required to
provide 32 inches clear width. -- Sec. 511.(a)
2) Provide 44 inches clear on each side of doorways. -- Sec. 511.(a) 1.
3) Provide a. 60 inch diameter clear area within the toilet room(s).
- - Sec.511.(a)2.
4) Provide a clear area 42 inches wide and 48 inches long in front of at
least one water closet. If in a compartment and door is on the side,
provide a clear access width of 34 inches. Door may not encroach into
clear area. -- Sec. 511.(a)3.
5) A 48 inch access width is required to the handicapped compartment.
- - Sec. 511.(a)3.
6) Grab bars are required behind and on one side or on both sides of
handicapped water closet. Side bar is required to be 42 inches long (min)
and extend 24 inches in front of water closet. Rear bar is to be 24 inches
long in a room or 36 inches long in a compartment. The top of the bars are
to be 33 to 36 inches above the floor. -- Sec. 511.(a)5.
7) Provide a clear area under at least one lavatory. 30 inches wide X 29
inches high X 17 inches deep minimum. -- Sec. 511.(b)1.
8) The bottom of one mirror, opening of a towel fixture, and disposal fixture
is required to be within 40 inches of the floor. -- Sec. 511.(b)2. &3..
9) The top of the seat on the water closet is required to be 17 to 19 inches
above the floor and cannot be sprung to return to the lifted position.
- - Sec. 511.(a)4.
•
Garfield County
Building & Planning Department
109 Eighth Street, Suite 303
Glenwood Springs, CO 81601
(303) 945 -8212
Plan review based on
the 1988 Uniform Building Code
Project Number: Name: C & C Properties
Address: 5320 County Road 154, near Glenwood SP. Date: June 7, 1995
Contractor: Same
Occupancy: B2 Designer: Same
Type of Const: V -N Engineer: None indicated
Plans Examiner: Art Hougland
Report created using Plan Analyst software by b w & a. (719) 599 -5622
Portions of the material contained in this program are reproduced from the
Uniform Building Code ( 1988 edition) with permission of International
Conference of Building Officials
SHEET IDENTIFICATION CORRECTION REQUIRED
1 Plan Exist. Warehouse: Provide 1 exit(s) from this area. -- Table
33 -A & Sec. 3303.(a)
2 Plan No information provided: Provide a landing on both sides of
door. Note: The step & size requirements. -- Section
3304.(i) & (j)
3 Plan No information provided: The exits from this area do not provide
the minimum required width. -- Sec. 3303.(b)
4 Plan No information provided: Provide handicap access to the
building. -- Sec. 3301.(e) & Table 33 -A
5 Plan Not indicated on plan: At least one toilet for each sex is
e$5 jM,y'i required to comply with the handicap requirements.
402140)(d& -- Table 33 -A and Sec. 511.
6 Plan Not indicated on plan: The require 0 inch clear area is not
provided in this t et room. -- Sec. 511.(a)2.
7 Plan Not indicated on plan: vide a 48 inch clear access width to
the han plan:
compartment. -- Sec. 511.(a)3.
8 Plan Not indicate on plan: Provide the required 48 inch clear space
in front of one water closet. -- Sec. 511.(a)3.
9 Plan Nnd ated on plan: Provide the required 42 inch clear width
/ at one water closet. -- Sec. 511.(a)3.
46 1J07 /2<Cfr'R'3y !3/c egvS /JO C /1847 !S n9oc TU /lfriiroGn
c.7 ee eoP lO q
Page # 2
Required corrections for:
Project Id: C & C Properties
Address: 5320 County Road 154, near Glenwood SP.
# SHEET IDENTIFICATION CORRECTION REQUIRED
10 Plan Not indicated on plan: Providthe required 29 inch height, 30
inch clear wid , & 17 inch clear depth under at
least one 1 tory. -- Sec. 511.(b)1.
11 Plan Not indicated on n: Provide at least one mirror with the
bot om within 40 inches of the floor. -- Sec.
12 Plan Not indicated on plan: Grab bars need to be shown on the plans
that comply with section 511.(a)4.
13
14 Plan Not ind. for Shed Roof: Show all design loads used in the design
of this building on the plans. (snow, wind, seismic,
live, etc.) -- Chapter 23
15 Plan Build.Insp. to verify: This beam is not supported to the
foundation. Jc s5/" stuo5 y" or rsttrp rc r'ort,
5t91
16 Plan See attached information: These rafters are over the maximum
allowed span. -- Sec. 2517.(h) 2.
w its Cc r1 0901 /ft'C DdvOo C r Tots :0 -
•
•
Project Number: Name:
Address: Date: June 7, 1995
Beam ID: Shed roof for C &C Properties @ 5320 C.R. 154
BEAM SPAN= 16.0000 Feet.
Uniform Load
The plf on the beam is 40.0 L.L and 10.0 D.L.
Note: Based on top edge having continious lateral support.
HEM -FIR #2
Size = 1 - 2 X 8
Used REPETITIVE MEMBER bending.
Increase in allowable for duration of load = 15 %
BENDING
ALLOWED = 17378.5 inch /lbs
ACTUAL = 19200.0 inch /lbs
MEMBER OVER STRESSED
SHEAR
ALLOWED = 625.3 pounds
ACTUAL = 369.8 pounds
Shear OK
DEFLECTION
L /180 = 1.0667 inches
L/240 = 0.8000 inches
L/360 = 0.5333 inches
ACTUAL Total Load Deflection = 1.1056 inches
ACTUAL Live Load Deflection = 0.8844 inches
NOTE DEFLECTION
NOr/E: Root'?
Cony- Vtna,- per
/ P conec19Het
i
•
•
Project Number: Name:
Address: Date: June 7, 1995
Beam ID: Shed roof for C &C Properties @ 5320 C.R. 154
BEAM SPAN= 15.5000 Feet.
Uniform Load
The plf on the beam is 40.0 L.L and 10.0 D.L.
Note: Based on top edge having continious lateral support.
HEM -FIR #2
Size = 1 - 2 X 8
Used REPETITIVE MEMBER bending.
Increase in allowable for duration of load = 15 %
BENDING
ALLOWED = 17378.5 inch /lbs
ACTUAL = 18018.8 inch /lbs
MEMBER OVER STRESSED
SHEAR
ALLOWED = 625.3 pounds
ACTUAL = 357.3 pounds
Shear OK
DEFLECTION
L /180 = 1.0333 inches
L/240 = 0.7750 inches
L/360 = 0.5167 inches
ACTUAL Total Load Deflection = 0.9737 inches
ACTUAL Live Load Deflection = 0.7790 inches
NOTE DEFLECTION
•
•
Project Number: Name:,
Address: Date: June 7, 1995
Beam ID: Shed roof for C &C Properties @ 5320 C.R. 154
BEAM SPAN= 15.0000 Feet.
Uniform Load
The plf on the beam is 40.0 L.L and 10.0 D.L.
Note: Based on top edge having continious lateral support.
HEM -FIR #2
Size = 1 - 2 X 8
Used REPETITIVE MEMBER bending.
Increase in allowable for duration of load = 15 %
BENDING
ALLOWED = 17378.5 inch /lbs
ACTUAL = 16875.0 inch /lbs
Bending OK
SHEAR
ALLOWED = 625.3 pounds
ACTUAL = 344.8 pounds
Shear OK
DEFLECTION
L /180 = 1.0000 inches
L/240 = 0.7500 inches
L/360 = 0.5000 inches
ACTUAL Total Load Deflection = 0.8540 inches
ACTUAL Live Load Deflection = 0.6832 inches
NOTE DEFLECTION
_ .11
• 4 o
' k .
TO 77.
---
t '
1 61-11---
c / - 9,_-- - 1
14- I
e e t
) 1,2
1 i
....\-,.. )
-r 1 4-16 ill 24
l „
1 -x
/ 0 f
1 \ i c . •
_-- :i
V Warehouse Showroom 77 9 4.1. ,
] - , 13
---ii r
(9 (
---- fry)
kil 12 ---)1- - — - ,
„ —
, \
sr .
/ tl_ _
. a .
i •-•", ..
..--- 1 - Li 1/4,
7, ,
17/ 1 16
s 11 i ll __
, ■ _ ,
)
Work Bench C —_
E Ma/
_.,
,,,,,:,q
F ,,,,,,./2,,,..„ / c,
0 „Hi:
t‘
-----
. ,
COZY CORNERS 5320 ROAD 154
Existing Shed Roof --_------
2 X 8 Rafters 24" apart \ / Steel Girder
3J4" plywood sheeting \ \ ,
I=
f — ter`
`.. __ - - 1 ' Existing
. I 3 es. 2 x 10's staggered over 40' length Steel Building
(lashed to rafters with metal straps and
lashed to studs with metal plates and metal snaps) 11•
• 4 x 4 studs (6 studs spaced 96" apart) t
(metal base plate on bottom)
4" Rehicrced Concrete Slab
�
' —•I 2al e ' x ac h s squtuare d over 3" Gravel Base \
1 '\ \
EZ Concrete Base ` 1
Existing concrete flocs
I
16• 1
Shed Area 40' x 10'
4 • J
..- cr) 4: i
I
I
It
x
iciotoc it s ; W yo7,...,a,/„0
d
i
1 1
p, o ■
II
Y ti uc.c f- '
,
k k
ti1 v
N: il _ .1 it- \ .
1 : Ze e "'CC -Oiriltie2. ,/ A_ h j
'1 •I r rs
�}. & I S /N� =a-r
.
, J - 4,-/- /w.--c) ■
t S c - 4J `,'
y c Q\
1 L
— — — / 1 0
pp
C1
b
j\
M
4i
I i ., TArT pdo2 • , Or -.rear'
T yr3 LO I
i - I + ' r
r .,30
,r-a d -.if" c'o sr Gt e-- Dart ce
�D . X V / / S74 4a,la -. _XLr',9 /LCp 6rc keel '
(r�-is i eei td . t ` c_ Tv- e4 ce W - f 2 /�sC
r 7/., ( p' -7-rz,-. �y�y
• •
Sec. 104. (b) Additions, Alterations or Repairs. The present
wording in this section will allow existing buildings to be altered,
repaired or modified without complying with all provisions of the code
as long as the new work complies with the code. The code . also intends
that the new work will not make the existing building unsafe nor should
the new work cause any portion of the existing building to be in violation
of the code. For example, any new addition or new alterations should not
remove or block existing exits.
There are two separate provisions which relate to limiting any
altered building to the height, number of stories and area specified for
new buildings. At first, these two provisions seem to create a
redundancy, but further study reveals that the first addresses the specific
case of a change in occupancy and would apply even if no alterations or
additions were made to the existing building. The second provision has
the effect of not permitting an addition to an existing building if the
existing building already is nonconforming due to excessive height,
number of stories or area.
Section 104 (b) also intends to permit additions or alterations to
existing noncomplying buildings only when such additions or alterations
will result in conditions no more hazardous than existing conditions.
tt�tie�r �r �� SSS hV ii In. d1tIMS Wifitl � Neil
THIS CARD IS POSTED ON THE JOB
24 HOURS NOTICE REQUIRED FOR INSPECTIONS
BUILDING PERMIT .
A FIELD COUNTY, COLORADO
Date Issued 9 . .... FIELD
Area Permit No 5 �
AGREEMENT
In consideration of the issuance of this permit, the applicant hereby agrees to comply with
all laws and regulations related to the zoning, location; construction and erection of the
proposed structure for which this permit is granted, and further agrees that if the above
said regulations are not fully complied with in the zoning, location, erection and
construction of the above describe ' t ucture, the permit may then be revoked by notice
from t Bu' i In cts a I 1 LATELY BECOME NULL AND VOID,
Use �� � - _'' Alb
Address o Legal n 1 1, - n F
Owner ) / le Contractor 0 WA,J ea
Setbacks Front Side Side r e
R a
This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection.
INSPECTION RECORD
Zoning Roof Covering
Electric -Final (by STATE inspector)
Footing c S F o¢ —
Foundation
Plumbing- Underground
Gas Piping Heating Ventilation
Frame 4. / Insulation
Plumbing -Rough � �4-� ,; Drywall to- - 9s 2,,/
Electric -Rough