Loading...
HomeMy WebLinkAbout5569 • No. 5569 GARFIELD COUNTY BUILDING, SANITATIONaad PLANNING DEPARTMENT 109 8th Street Suite 303 Gkowood Springs. Colorado 81601 (303) 945-8212 Job Address. 6200 County Road 320, Rifle Nature of Work Building Permit UscofBuilding C^rnge k Caryort Owner Cecil & Betsy Phillips Contractor Steve Stanek Amount of Permit$ 311.85 Date June 20, 1995 Permit: 189.00 Plan : 122.85 Paid $122.85 5 -26 -95 S. Archuleta Clerk • BUILDING PERMIT APPLICATION GARFIELD COUNTY. COLORADO Applicant to complete numbered spaces onl PERMIT NO. S S PARCEUSCHED NO. JOB ADDRESS 6, zoo 32 / ,,e,, 1 LEGAL LOT NO. BLOCK SUBDIVISION DESCR. H.f'e (. 2 OWNERC %Qksy \`.i � t R ta ADDRESS &I PH. Las-I WK PH. (oaS•SS -L 3 CONTRACTOR S]"I✓t SAL N.LK. ADDRESS PH. LICENSE NO. 4 ARCHITECT OR DESIGNER ADDRESS PH, LICENSE NO. 5 ENGINEER ADDRESS PH. LICENSE NO. 6 SF OF BUILDING S.F OF LOT /O • / 9 HEIGHT NO. OF FLOORS / 7 USE OF BUILDING q is,S e_. 8 CLASS OF WORK: ...�yyyy o NEW rI DDITION C ALTERATION oREPAIR oMOVE oREMOVE 9 DESCRIBE WORK: 78 / 0 ?cLA�r- st- ,(��'' aZ Ce2O VX�_ 10 GARAGED SINGLE DOUBLE ((WO SINGLE DOUBLE DRIVEWAY PERMIT ON SITE SEWAGE DISPOSAL PERMIT SITE PLAN 1 1 VALUATION OF WORK: $ / 7 Z /SA 7s DJUSTED VAL.$ K PLAN CHECK FEE /a707.87.5- PERMIT FEE �e � 0 SPECIAL CONDITIONS: SCHOOL IMPACT FEE .`.//// NO. OF BUILDINGS ON USE OF BUILDINGS NOW ON N! • PARCEL PARCEL TOTAL FEE 3/ 2:c OCC. GR./1 – / � / " CONST.TYP J NOTICE WATER SUPPLY DATE PERMIT ISSUED (9 sZt7 - 9s SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, SPECIAL APPROVALS REQUIRED RECEIVED NOT REQUIRED VENTILATING OR AIR CONDITIONING. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS ZONING NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. HEALTH DEPT. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES FIRE DEPT, GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE SOIL REPORT AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF SETBACKS fONa w_tr) ST\) \ p Y ma, . re L19S \\ � �, (Date) Sir of e� entractor a rized age,i going read . sii nderstood 41 . ab• . FLOOD HAZARD . B 11 p / pr / tg �� Planning p IApprovaVd.: T r MANUF HOME — — g OTHER AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND /OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER _ AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING 0 . 2 - • •EING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JU • SDUS PT . THE REVIEW OFT - , ' 1 •LANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPT4M. OF ANY' S': (0 • :ILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE RESPON ITTQQ FiQrFl E • AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER, LD t.UIER OWI IZ1 1 1 1 ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. (�+��L� GarTdL`i1NW3• LL •,33 ACKNOWLEDGE THAT 1 HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL 1 / 4 l 1 rd %7a. ? a -7.f GARFIELD COUNTY BUILDING AND PLANNING NOTICE A COPY OF THIS PLAN REVIEW IS ATTACHED TO THE OWNER'S OR CONTRACTOR'S COPY OF THE APPROVED PLANS. THIS PLAN REVIEW IS PROVIDED IN CONJUNCTION WITH OR IN PLACE OF REDLINING THE APPROVED PLAN. IT IS THE RESPONSIBILITY OF THE OWNER AND /OR THE CONTRACTOR TO CLOSELY REVIEW THE PLAN REVIEW AND VERIFY THAT ALL CORRECTIONS NOTED ARE BROUGHT INTO COMPLIANCE WITH CODES ADOPTED BY GARFIELD COUNTY. THE ISSUANCE OR GRANTING OF A PERMIT OR APPROVAL OF PLANS, SPECIFICATIONS AND COMPUTATIONS SHALL NOT BE CONSTRUED TO BE A PERMIT FOR, OR AN APPROVAL OF, ANY VIOLATION OF ANY OF THE PROVISIONS OF ANY CODE, ORDINANCE OR RESOLUTION OF GARFIELD COUNTY. PERMITS PRESUMING TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF CONSTRUCTION CODES OR OTHER ORDINANCES OR RESOLUTIONS OF GARFIELD COUNTY SHALL NOT BE VALID. THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE CHIEF BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA, OR FROM PREVENTING BUILDING OPERATIONS BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF CODES, ORDINANCES OR RESOLUTIONS OF GARFIELD COUNTY. (Authority under the 1988 Uniform Building Code Section 303 (c). titled: Validity of Permit.) THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOIT AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABINIFIAY,GARFIELD COUNTY FOR ERRORS OMISSIONS OR DISCREPANCXWNRESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONS - MIN - ION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER, BUILDER AND OWNER. COMMENTS AND NOTATIONS ARE INTENDED TO''9T' L IVE AND INN SUPPORT OF THE OWNERS INTEREST. w. M Art Hougland, uilding Official PRNOTICE 109 8TH STREET, SUITE 303 • 945 8212/625- 5571/285 -7972 • GLENWOOD SPRINGS, COLORADO 81601 • /10? .7 ill; NO 5 ; Nittrhi tHL Anc.2.u4v, J A0 4 Yiiafri4216° dr.() ( ; N ) C fie "lite CLIION C.).), -4 Jr) r 7.11. rk't •'''C'; r 4 n r rioa NjOdil PIN 1 .1 ilijNOO PLANS EXAMINATION June 15, 1995 Cecil and Betsy Phillips 6200 320 road Rifle, CO 81650 Plan Review # 70 -95 This plan review represents an examination of plans / drawings showing substantial conformity with applicable codes of the Garfield County Building Dept. Subject to the following conditions. Respectfully, William D Allred LC.B.O., Code Consultant (970) 945 -4418 PLAN REVIEW: if 70 GARFIELD COUNTY DATE: PERMIT NO: June 15, 1995 PLANS EXAMINATION ADDRESS: 6200 320 Road Rifle, CO OWNER: CONTRACTOR NAME: Cecil and Betsy Phillips NAME: Steve Stanek MAILING ADDRESS: MAILING ADDRESS: TELEPHONE: (970) 625 -1074 TELEPHONE: (970) BTJII,DING PERMIT FEE' Fees are based on the March - April 1994 edition of the Building Standards. Garage: 784 sq. ft. X $16.69 = $13,084.96 Carport 280 sq. ft. X $16.69 = $ 4,673.00 Owners Calculated Valuation: $17,757.96 Building Permit Fee: = /9 Plan Review ( 65 %: = $122.85 Total Fees: $311.85 ELECTRICAL PERMITS MUST BE OBTAINED SEPARATELY FROM THE STATE ELECTRICAL INSPECTOR. THIS PERMIT DOES NOT INCLUDE ELECTRIC. Independent Professional Building Inspection Bill Allred 45855 Hwy 6, Canyon Creek # 63 Glenwood Springs, CO 81601 (970) 945 -4418 June 15, 1995 Cecil and Betsy Phillips 6200 320 road Rifle, CO 81650 CONDITIONS FOR. PLAN REVIEW # 70 -95 SUBJECT TO THE FO TOWING ONDITIONS: GENERAL REQUIREMENTS: 0-1 All references are taken from the 1988 Uniform Building Code (U.B.C.), 1988 Uniform Plumbing Code (U.P.C.), and the 1988 Uniform Mechanical Code (U.M.C.) The Approved Plans, Permit, and Plan Review, are to be kept on the site during construction. Plans and Permits must be available for reference during inspections. Also, reference the generic drawings from the applicant. Also, reference (Section 2907., with exceptions , U.B.C.) for foundation design (see attached) The attached Code interpretation is only prescriptive for M -1 occupancies only (garages). Please be aware that the Garfield County Building Official, may require additional information concerning soils tests, etc., per (section 302 (b)., U.B.C.) and (Section 2905, U.B.C.) 0-15 Notify all utilities for line locations and approval prior to beginning any excavation on site (Public Service Electric, Natural Gas, Telephone, etc.) BUILDING CODE ITEMS: B -10 Anchor bolts shall comply with, (Section 2907, (f), U.B.C.) B -21 Provide premises identification which is legible from the street in accordance with, (Section 513, U.B.C.) • FOUNDATION REQUIREMENTS FOR RESIDENTIAL ACCESSORY STRUCTURES Sec. 2907, Uniform Building Code (a) General Footings and foundations, unless otherwise specifically provided, shall be constructed of masonry, concrete or treated wood in conformance with U.8. C. Standard No. 29 -3 and in all cases shall extend below the frost line. Footings of concrete and masonry shall be of solid material. Foundations supporting wood shall extend at least 6 inches above the adjacent finish grade. Footings shall have a minimum depth as indicated in Table No. 29-A un- less another depth is recommended by a foundation investigation. (b) Bearing Walls Bearing walls shall be supported on masonry or concrete foundations or piles or other approved foundation sys- tem which shall be of sufficient size to support all loads. Where a design is not provided, the minimum foundation requirements for stud bearing walls shall be as set forth in Table No. 29-A. Exceptions: 1. A one -story wood or metal frame building not used for human occupancy and not over 400 square feet in floor area may be constructed with walls supported on a wood foundation plate when approved by the building official. 2. The support of buildings by posts embedded In earth shall be designed as specified In Section 2907(g). Wood posts or poles embedded in earth shall be pressure treated with an approved preservative. Steel posts or poles shall be protected as specified in Section 2908(h). Treated - Stud Stud Vall Vail Rnriset Anchors Treated Grade Grade Treated Sill & Sill Foundation Plates ' • 4' Concrete Slab Wood Sill Plate Concrete Slab on Grade Optional Brick Stud Vall (16' o.c. 4' Concrete Slab an Grade Veneer with N M with brick veneer) netnl ales at 1/2' Exp. Material 2 sf /tie & • 4' Conc. Slab Stud Wall 24 or. Horiz. on Grade Treated Sill WIOx10 Wlre , , Mesh Grade Z Grade WAY c • • 1/2' 'Anchor Bolt °D #4 Rebnr. 3 Max 6' on center 45 Max. 8' Foundation or Block Foundation Vall 12' . #4 Rebar (Typ). 16' Monolithic Frost -Depth Spread - Footing B -32 The main house only, provide smoke detectors in accordance with (Section 1210 (a)., of the U.B.C.) One smoke detector is required on each level and they shall be inter connected. Audible from the bedrooms with the door dosed and in compliance with the listing that comes with the detectors (coordinate with the County Garfield Building Inspector, during inspections). On existing R -3 occupancies battery operated (ok). B-47 Please submit roof truss diagrams bearing the stamp and signature of a Colorado Professional Engineer and indicating design for a minimum of 40# / sq. ft. live load, (Section 2305, U.B.C.) Additional field framing may be required. G -1.1 Every attempt is made by the Building Department to perform a thorough plan review, however please be aware of (Section 303 (c) of the U.B.C., which states): This issuance or granting of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. The issuance of the permit based upon plans, specifications and other data shall not prevent the Building Official from thereafter requiring the correct- ion of errors in said plans, specifications and other data, or from preventing building operations being carried on thereunder when in violation of this code or of any other ordinances of this jurisdiction. All construction shall be approved prior to the issuance of Certificate of Occupancy V V I Art Hougland, Bill Allred, (Building Official) (Plan Checker) Garfield County (970) 945 -4418 , , 11n c r K 1.5 r e, i, . �' I 1 �T \ oT ( q� 2 C. eY� { l I 1 ■ 1 r I I h....._.. 1 .� I p 1 ! t t ! Q Of:, i L .' 1 _I. / ._ ��._ _ . I _. ` ` \� `I -_ -..- 1 . _ 1 I i - Y CI s J ` \ f j + �i r C �� i._ 1 I -. ; N / 7 , I J i I J 4 1I ./I I l ; I � _ , .. i 'I C b qZ I I1 x . R 1. a- 1 I_. I I I i 1..1 • ' I __.__.._ _.. _ _._ I • -' j I - - - : .. .:. L . __� • � 1 1 _. - --__ s. I 1 1 /0 I • ' _- . -I 1...- -. __.... _ _ -. __.. - li • I � �_.._ 1 1 . . .. . ._ . • I • i • f I • : 9 I . . ... .. . . . r . . �; • I, • .- r . • • • I. r �� l � I • • : I .I. I. �� 1 1 I : _ I I • L . _ C1' ' �I • I I 1 !1 _ I 1 1 I • 1 I • KS_ _ _ • f l ' • 1 _. 1 I• I I • I. - I_ I - , - I N ; i { 1 j I I I I I _ -I. • 1 - _ _.._. i._ - - -.. - - - - - -- - • 9.. 1 p_ _1_ _ I ;� __ - - I • 11 L _ _ L • 1 1 • l 1 1- 1 - - -1 - _,_ � l �_� i..- I • • � � 1 � 1 , ^ ,,,,,,,,,,,;,..osti...... „ _ , O c.)‹..).0_ c _ ,,, T II L il It 1 t ,_----__`-____-_---^_'`-,-----_-'---�-.-'.-'-_--~_-_----'-_---_-__-_'-_--__-----`--------_ ~ • -� ' - . . NE COR. ,- /— sea 26 N89'41 '27"E f / / ' .72 x ‘ TWO STORY ' ,�, c 9aras¢. LOG HOUSE ma JO ' W.C. 0) ROAD am: b ,p SCALE ' , + 200 0 200 _ S89'32'lO'W � / e _ 6€6:29' _ _ _.; — JO' W.C. 1' = 200' NOM RECORD DISTANCE BETWEEN WITNESS CORNERS IS 666.29 it FIELD MEASURED DISTANCE $ 66.47 fT. RExER TO COMMONWEALTH TITLE INSURANCE COMM/TMEWT N0. 9210016 DATED SEPT. 25 1992 DE/B/T a t FOR ACCESS ROAD LEGAL DESCRIPTIONS LEGAL DESCRIPTION A parcel of land being the NE1 /4NE1/4NE1/4 of Section 26, T6S, R94W of the 6th P.M., Garfield County, Colorado being more fully described as follows: Beginning at the Northeast Corner of said Section 26, being a stone corner, thence S00'40'53"E 665.63 feet along the East line of said Section 26; thence 589'32'10 'W 666.29 feet along the South line of sold NE1 /4NE1/4NE1/4; thence NOO'37'54 "W 66742 feet along the West line of said NE1 /4NE1/4NE1 /4; thence N89'41'27"E along the North line of said Section 26 665.72 feet to the POINT OF BEGINNING. IMPROVEMENT LOCATION CERTIFICATE I HEREBY CERTIFY THAT THIS IMPROVEMENT LOCATION CERTIFICATE WAS PREPARED FOR MESA NATIONAL BANK, THAT IT IS NOT A LAND SURVEY PLAT OR IMPROVEMENT SURVEY PLAT, AND THAT IT IS NOT TO BE RELIED UPON FOR THE ESTABLISHMENT OF FENCE, BUILDING, 01? OTHER FUTURE IMPROVEMENT LINES I FURTHER CERTIFY THAT THE IMPROVEMENTS ON THE ABOVE DESCRIBED PARCEL ON THIS DATE, 11/20/92, EXCEPT UTILITY CONNECTIONS, ARE ENTIRELY WITHIN THE BOUNDARIES OF THE PARCEL, EXCEPT AS SHOWN, THAT THERE ARE NO ENCROACHMENTS UPON THE DESCRIBED PREMISES BY IMPROVEMENTS ON ANY ADJOINING PREMISES EXCEPT AS INDICATED, AND THAT THERE IS NO APPARENT EVIDENCE OR SIGN OF ANY EASEMENT CROSS /NG OR BURDENING ANY PART OF SAID PARCE , EXCEPT AS NOTED. RICHARD L, HOL L.S. 1 35 0 1 N : f. e " % Lt 4- 4/ NOTE.. t t 4-1 COhO NATIONAL FLOOD INSURANCE MAPS DO NOT IND /C ' "OPERTY AS BEING /N A 100 YEAR FLOOD PLAIN. IMPROVEMENT LOCATION CER77f7CA7E RICHARD L. HOLSAN 6200 320 ROAD Profession/ Land Surveyor RIFLE; COLORADO 4773 214 Rd. Slit Colorado (303) 876 -2947 DATE 11/20/92 PRa1. 92102 I SHEET 1 OF 1 THIS CARD IS POSTED OD __ B THE BB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT G RFIELD COUNTY, COLORADO Date Issue /9 S " zoned Area Permit No.. AGREEMENT �/ i In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described ructure, the permit may then be revoked by notice from t(( lje'ZFaont�B}Iil�ing�h ( l5pe forE 1 ATELYCOME NULL AND VOID, Use (S ! _ t � -- 3 e Addre Legal DescripP t r i av b 3o I r f • ( y ` - ! c Owner ?e0. 6C, ; it 1�. .5 Contractor V &A) g 4.$ lig - t Setbacks Front Side Side Rear This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection. INSPECTION RECORD Zoning Roof Covering k.----7 4._a7_t5 Electric -Final (by STATE inspector) Footing Foundation 7- Plumbing- Underground Gas Piping Heating Ventilation Frame Insulation Plumbing -Rough Drywall Electric -Rough (by STATE inspector) Final 7,-,23,9c-- ✓..< - ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING — WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 945 -8212 109 8th Street, County Courthouse, Glenwood Springs, Colo. APP OV E D DO NOT DESTROY THIS CARD Date } B y j a / a