HomeMy WebLinkAbout5637 1 • No. 5637 GARFIELD COUNTY BUILDING SANITATION and PLANNING DEPARTMENT 109 Rib Strccl Suite 303 Glenwood Springs, Colorado 81601 (303) 945 -8212 Job Address 1237 County Road 326, Silt Nature of Work Building Permit Use of Buildin: 1 • • - _ Owner Kelly & Karen Protz Contractor Owner Amount of Permit$ 259,45 Date August 18, 1995 Permit: 153.00 Plan 99.45 Paid $99.45 S. Archuleta Clerk BUILDING PERMIT APPLICATION . onIFIELO courrtv, coLOnADo Applicant io complete numbered spaces only. PERMIT NO. 3 3 7 PARCELi5Ci•ED NO. Jon Ap0SESS . 3 0. 1. aO // _I . i 76 2 _._.- 1 LEGAL LOr '10 [31.01EK SUBDIVISION DESCR, f / ( o �y 2 OWNER Jfy , f K4g, D st 0DDRFSS �: e . . jr.... 1`0 777'3» INS P1 1 ar a1lf 1 12 3 GONTRACIOR / ADDRESS Pn upEssp No 4 ARC! II f EDT OR DESS MR �r / 8L4 AIIDRFSS FeI UCFNSE NO 5 ENGINEER 4// /1 ( ADDUCES Pn 1.10015E 1 — 6 5.00E BUILDING 1 'Cf 8 Or 120T f lr1:111 9 / 7 10 Or n 0012S 7 USE OF BUILDING Two V C'.AK •.i i • - j B // .1 e '. 8 Class or won ,/ )(EV/ ri 0012)11100 nLL AL IF.. PA 1 ION nl? 11 MOVE II REMOVE »/ / / � �y(J 9 DESCRIBE WonK: vhcry1 i r, 214. C J 44/�/Q '' ` eiCi O _ tit i AO VC' • _ • . c..' r ./{! • R / • el {'••L L ge C • lo 0 31N3LE 0 DARPDR I' All IDLE DGI Iifl r-: DRIVEWAY PERMIT ON 511E SEWAIE DISPOSAL PC0M11 511 PI 114 � 1 1 Vnrun ion ro1 wonK. 1 ‘7957 ADJUSTED VAL 1 P1 01) 01 1 rr1< FEE '//• VS– P01201112121 4,/c3 /r 0 SPECIAL CONDITIONS ffi / pp V< 6 5011701 IMPAr.T EET pin OF f11111L1111Ii or] 11=F ,T PIIILPR If IC' rli ''oV ()NI To IAL EC1:$ e,e.± 4 OCC GR L01111 (ID it fl NOTICE WAIF, -R 9llPl'LY DATE FERMI 11551100 8 y5 .' SEPARAT PERMIf3 ARE REQUIRED FOR ELECTRICAL, PLUM01110. 111 - AlIt u3. n. V EN TILATING OR AIR CONDITIONING. Sr feeTAnmmvm RK RecEmED U.uEmumEU T118 PERMIT BECOMES NULL AND VOID IF WORK OR G0115101)07 AD 1FIt?R'JPD Is J.0r ur1G NOT COMMENCED WITHIN 100 DAYS, OR IF CONSTRUCTION DR WORK 1; susrrr OR ABANDONED FOR 0 PERIOD OF 1110 DAYS AT APE TIME 412100 WORK IS COMMENCED YEN 111 DPI' I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED s 41 APPLICATIOI I AND KNOW THE SAME TO BE TRUE AAID CORRECT ALL PROVISIONS OT LAWS AND ORDINANCES 121f ?0 DEPI GOVERNING THIS TYPE OF WORK WILL DE COMPLIED '41!1211 WHETHER SPECIFIED HEREIN OR NOT THE GRAN [VI0 OE 0 PERMIT DOES NDT PRESUME 10 8115 5011. REPORT AUTHORITY TO VIOLATE 00 CANCEL 1HE PROVISIONS OP ANY 0111ER 5101E DR — — -- 'L LOCAL LAW REG TINT C •151 RUC LION 012 TH PER FORMAL 101E OF SPI[IAGKS CONST• A 1 lA a—% Date � — i FI ODD !- EVA.1:11 r " Signature 1 r (Mr ErAntal or ei horlv.ed ager having Ina f undreslnod amen ohnvn — , MANLT I I01A1' B Ing De,arlment Approvaldatn -Ian inn en. lens AemmVdn! - 0111ER AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, COPT TRACTOR AND /012 TIIE AGENT OF TIIE CONTRACTOR 012 OWNER 10 CONSTRUCT THE STRUCTURE AS DETAILED 00 PLANS AND SPECIFICATIONS SUBMI f T ED TO AND REVIEWED BY 111E BUILDPJG DEPART MEN T IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUfIIORITY GIVEN 10 3020.201 CRS AS AMENDED. THE 810140R FURFIIER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NO FULLY COMPLIED WITII IN THE LOChfION, ERECT IOPJ, CONST RUCTION AND 1.15E OF THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN 30 REVOKED BY NOTICE FROM TIIE C000IY AND TIIAT 111EN AND MERE If SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMIT BASED UPON PIArIS, SPECIFICA11ON5 AND OTHER DA FA SIIALL 00 1 PREVENT 111E BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENT INC BUILDING OPERATION BEING CARRIED ON TFIEREUNDER WIIEN 10 VIOLATION OF THIS CODE Oft ANY OTHER ORDINANCE OR REGULATION OF 1015 JURISDICTION, THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICA DONS AND INSPECTIONS CONDUCTED THEREAF1ER DOES NOT 0005121 TUTE AN ACCEPTANCE OP ANY RESPONSIBILITIES OR LIABILITIES BY GARPIELD COUNTY P00 ERRORS, OMISSIONS OR DISCREPANCIES THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CON5I RUCTION RESTS SPECIFICALLY WIT11 111E ARCHITECT, DESIGNER, BUILDER AND OWNER. COMMENTS ARE INTENDED TO BE CO1ISERVAI IVE AND IN SUPPOR T OF 111E OWNERS IN 1 Rf205 F. Garlorrn.003 I HEREBY ACKNOWLEDGE 11101 I HAVE READ MIL/UNDERSTAND 111E AGREEMEN 1 ABOVE (1011 IAL RP ) Hid. Reb.r`C i C ,L 5 ;5447 ` \ elr• P.... 3 .139'53'17'E. 1323.76 nens to •nc corner 1 -141------- ,. DrtF �� - NWI /4NEI /4 Sect 35 T.6 S.. R.92. re M . U 7 i / ` U . / • — M V APPkoc � fa • e... D J A4 fork- /1 F a`r .F v - - - . `lei Re on A 453 r f 0 14 O I " CI 1 ° tto ■ Z Pel• \ 4\ . Gow d ate .«I r •b N. 1 ,n e,5. \ Co a ?2t , • • 1 - : I C 0 /11:)1.) is \ N. Pole 0 •rhnd Utility 11... _ _ Irrl S.rlu Olr.h — C 1 44 k Count Road 326 (Chi•'erfleld Lone) pia a Dfhely IMPROVEMENT LOCATION CERTIFICATE o b g 9 3o Ke rr& 1-)05 CJ 1 6.s ?'dai i L eou (/y PROPFRTY DFSCRIPTION ) - r � Cv ��� 0°40 � / Township 6 South. Range 92 West of the 8th P.M. on 35. NWI /4NEI /4. aL -�-, 1 co i(p Garfield County. Colorado. 1a nU Addressed as: 1237 County Ro 3 28. Slit. .O 81652. P 17 FLOOD PLAIN STATEMENT r For 1 oar QQrO3t. 'f I have examined the FIRM map. of Garfield Count . doted Janu I lf7 J and the parcel shorn hen y cr y 3. 1988. Panel 080205 1400, Bu O J on does not be withal a 100 -year Hood Plain PIPROYEMENT LOCATION CERTIFICATE 6a , Perink- I hereby certify that this Improvement Location Certificate vas }, Title Company. that It Is not a land survey plot. or improvement establishment of fence. buildln surve f. for aldothatnit aith it not to be relied upon for the lines. S or o future Improvement N. I further certify that the Improvements on the above describ g � 27. 1993. except utility connections. are entirely Whin the boundaries o .parc.l December except as shorn that there are no eneroocMents upon the ducribed s by Improvements on any adjoining g promises. except as Indicated and tha th ey. is he. ..., intdin ar .ian of ofty easement a.....:__ , e l \ 7 \ 4 11% Sis it I kj a f k IA 51 \ ' ' 1 V _ I Ns A r-e p s -A T z r % R- a a� � T o �' 1 27 E t ? R` 7, T ? T m 1 G.- � F z n \ 3 4, / r a c K ) I rc g „ o� u SSca1 -IN. o- :s�?� 21oSJ 2 . . • . . L L. k ... n 2 $ Ci Si � % - • / § { s 4 � :. f ® �� \ / 'tcS { 't E ~ % � %ƒ - /s_ { /\ & r1 8 c o / \1 A ta & / . 0 \ / \ f )'- Q... � / c_. [ / u .. / \ ; . \ f k _� 2 ! y% \ 4 !{¥% \� - 7.. E /� \ ± i ¥ I , . . K Fed. R.har ';ba \ . Wire Nog. 5 .89' SS'17'E: 1323.76 - ` - DI¢en to nce crner - s io 11 Irrl —.i o Dlh o h NWI /4NEI /4 Section 35 • ce T.6 S.. R.92 W. Nr it a a ( APPRoK,lmate- — /, � " 1 .0eb{ ran. of I 9 �/ e %0 -- r Is ARC C TIT" I r 0 a p L•■ 433 ft Hires �_ 0 . Z CI a r PoIo e b n /f //�� N. 1 mi4 rN.h I a \ f S Z.IwC-S . . I ; I 1 1 ° _r N. Pelt - ° . OY.rheeJ Uf lllr y II... IrrI .ti. Dtteh _� - - ' • r I • Count Road 326 (Chi.•erfleld Lane) IMPROVEMENT LOCATION CERTIFICATE PROPERTY DESCRIPTION Township 6 South. Range 92 West of the 6th PA. Section 35. NWIJ4NEI /4. Garfield County. Colorado. Addressed ac 1237 County Road 326. Silt. CO 81852. r . FLOOD PLAIN STATEMENT 1 d parcel ed shown � maps of Garfield County. dated January 3. 1986. Panel 080205 1400. on does not IIe within a 100-year Flood Plan. ______ MENT LOCATION CERTIFICATE I hereby certif that this Title Company. that if Is no o �w� plat flffc ov.m a prep• h , , or Commonwealth e establish of fence. building survey and that 11 11 not to b. relied upon for the or o Inure Improvement 1 further certify that the Improvements on the above described parcel 00 1' date. Decembe 1993. except utility connection.. .. entirely within the bound of '? .. ail. except P that there are no encroachments !loon the described b hoProvemento on any adjoining premises except as Indioot.d. and mat there Is ea •,., • e. ar Mon of .w easement crn.. .-_ - - ` K 077, TR D cn CI L. O FOUNDATION REQUIREMENTS FOR RESIDENTIAL ACCESSORY STRUCTURES Sec. 2907, Uniform Building Code (a) General Footings and foundations, unless otherwise specifically provided, shall be constructed of masonry, concrete or treated wood in conformance with U.B.C. Standard No. 29 -3 and in all cases shall extend below the frost line. Footings of concrete and masonry shall be of solid material. Foundations supporting wood shall extend at least 6 inches above the adjacent finish grade. Footings shall have a minimum depth as indicated in Table No. 29 -A un- less another depth is recommended by a foundation investigation. (b) Bearing Walls Bearing walls shall be supported on masonry or concrete foundations or piles or other approved foundation sys- tem which shall be of sufficient size to support all loads. Where a design is not provided, the minimum foundation requirements for stud bearing walls shall be as set forth in Table No. 29-A Exceptions: 1. A one -story wood or metal frame building not used for human occupancy and not over 400 square feet in floor area may be constructed with walls supported on a wood foundation plate when approved by the building official. 2. The support of buildings by posts embedded in earth shall be designed as specified in .Section 2907(g). Wood posts or poles embedded in earth shall be pressure treated with an approved preservative. Steel posts or poles shall be protected as specified in Section 2908(h). Treated Stud Stud Wall Wall _ Raroset Anchors Treated Gracie Grade Treated Sill & Sill F oun dat ion Plates — • - 4' Concrete Slab Wood Sill Plate Concrete Slab on Grade Optional Brick -' Stud Vall (16' o.c. 4' Concrete Slab on Grade Veneer with : with brick veneer) metal ties at- 2 sf/tle & III 1/2' Exp. Material 1. 4' Conc. Slab on Grade tud Wall - 24'o,c. Hartz. W10x10 Wire 1:1:1 , Treated Sill Mesh ' ' Grnde o Gr de A% /lam% / //� ill •�rlt e _ 1/2' Anchor Bolt m 3 0 .. , ax. Ti; 8' Conc. or Block / Foundation Wall C `' 12 ' 14 Rebar CT yp) CI ar Iggl Monolit 16 hic Frost -Depth Spread- Footing • it PLANS EXAMINATION August 09, 1995 Protz Residence 1237 County Road 326 Silt, CO 81652 CONDITIONS FOR PLAN REVIEW # 117 -9 This plan review represents an examination of plans / drawings showing substantial conformity with applicable codes of the Garfield County Building Dept. Subject to the following conditions. Respectfully, William D Allred I.C.B.O., Code Consultant (970) 945-4418 • PLAN REVIEW: # 117 GARFIELD COUNTY DATE: PERMIT NO: August 09, 1995 PLANS EXAMINATION ADDRESS: 1237 County Road 326 Silt, CO 81652 OWNER: CONTRACTOR: NAME: Protz NAME: MAILING ADDRESS: MAILING ADDRESS: TELEPHONE: (970) 876 -5036 TELEPHONE: (970) BUILDING PERMIT FEE: Fees are based on the March - April 1994 edition of the Building Standards. Garage: 784 sq. ft. X $16.69= $13,084.96 Calculated Valuation: $13,084.96 Building Permit Fee: = $153.00 Plan Review @ 65 %: = $ 99,45 Total Fees: $252.45 ELECTRICAL PERMITS MUST BE OBTAINED SEPARATELY FROM THE STATE ELECTRICAL INSPECTOR. THIS PERMIT DOES NOT INCLUDE ELECTRIC. • Independent Professional Building Inspection Bill Allred 45855 Hwy 6, Canyon Creek # 63 Glenwood Springs, CO 81601 (970) 9454418 August 09, 1995 Protz Residence (free standing garage) 1237 County Road 326 Silt, CO 81652 CONDITIONS FOR PLAN REVIEW # 117 -95 SUB TO THE FOLLOW CONDITIONS_ GENERAL REQUIREMENTS: 0-1 All references are taken from the 1988 Uniform Building Code (U.B.C.), 1988 Uniform Plumbing Code (U.P.C.), and the 1988 Uniform Mechanical Code (U.M.C.) The Approved Plans, Permit, and Plan Review, are to be kept on the site during construction. Plans and Permits must be available for reference during inspections. 1) Refer to (Section 2907., of the U.B.C.) minimum requirements for monolithic slab on grade foundation systems. This type of construction is approved for unoccupied buildings only, M - 1 Occupancies and shall be placed on undisturbed soils only without fill and with ideal soils conditions only. Please keep in mind that the Garfield County Building Official, may require soils tests, if adverse soils are encountered during construction, (please see attached). B -3 Footing and foundation unless otherwise approved by the Building Official, shall be constructed of masonry, concrete, or treated wood in conformance with U.B.C. Standard No. 29 - 3., and in all cases shall extend below the frost line and meet the minimum depth as required in Table No. 29 - A., unless another depth is recommended by a foundation investigation, (Section 2907 (a)., U.B.C.) G -9 It is our understanding that the owner desires to construct the house for himself and therefore does not need a general contractor. However, it is the duty of the owner to notify the Building Dept. when the construction is ready for inspection. Schedule the inspection at least one day before such inspection. All work is subject to inspection prior to any cover up, (Section 305., entire Section of the U.B.C.) G -15 Notify all utilities for line locations and approval prior to beginning any excavation on site (Public Service Electric, Natural Gas, Telephone, etc.) B -10 Anchor bolts shall comply with, (Section 2907, (0, U.B.C.) B -21 Concerning the property, provide premises identification which is legible from the street in accordance with, (Section 513, U.B.C.) B -33 Concerning the main house, provide smoke detectors in accordance with (Section 1210 (a)., 4., and 5., U.B.C.) One detector is required on each level and they shall be inter - connected with battery back - up. The detector centrally located in the corridor. Also, a detector is required with - in each bedroom. (See attached hand - out and coordinate with the Building Inspector during construction). ( 4tt_fl °f't ° '& 0 K B-47 Please submit roof truss diagrams bearing the stamp and signature of a Colorado Professional Engineer and indicating design for a minimum of 40# / sq. ft. live load, (Section 2305., U.B.C.) Additional field framing may be required. B -50 Frame nailing to be compliance with (T.B.L. 25 - Q., U.B.C.) B -68 Roof rafters and ceiling joists shall be supported laterally to prevent rotation and lateral displacement when required by (Section 2506 (L)., Section 2517 (h), 6., of the U.B.C.) G -1.1 Every attempt is made by the Building Department to perform a thorough plan review, however please be aware of (Section 303 (c) of the U.B.C., which states): This issuance or granting of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. The issuance of the permit based upon plans, specifications and other data shall not prevent the Building Official from thereafter requiring the correct- ion of errors in said plans, specifications and other data, or from preventing building operations being carried on thereunder when in violation of this code or of any other ordinances of this jurisdiction. All construction shall be approved prior to the issuance of Certificate of Occupancy t} OULU \ Art Hougland, Bill Allred, (Building Official) (Plan Checker) Garfield County (970) 945 -4418 • GARFIELD COUNTY BUILDING AND PLANNING MINIMUM APPLICATION REQUIREMENTS for SINGLE FAMILY DWELLING CONSTRUCTION including NEW CONSTRUCTION MANUFACTURED HOMES ADDITIONS ALTERATIONS and MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. Adequate and complete information will prevent delays in the plan review process. Reviewing a plan and the discovery that required information has not been provided by the applicant may result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor may be required to provide this information before the plan review may proceed. This causes delays because other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. If you do not, it may be helpful to obtain a book titled "Dwelling construction under the Uniform Building Code. This book is available to you through this department at our cost. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following check list prior to and during design. Applicants are required to indicate appropriately and to submit completed check list at time of application for a permit: 1 1. Is a site plan included that indicates the distance of the proposed building or addition to property lines, other buildings, set back easements and utility easements? Yes I/ No of Not necessary for this project ( 2. Does the site plan include the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to property lines, wells (on subject property and adjacent properties) , streams or water courses? Yes No m Not necessary for this project _1/ a, 3. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes 1/ No n, Not necessary for this project (2) 4. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform buildin code or per stamped engineered design? Yes VI No („ Not necessary for this project (2) 5. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes No m Not necessary for this project: _<2, 6. Do the plans indicate the size an location of ventilation openings for the attic oof joist spaces and soffits? Yes _ No m Not necessary for this project (2) 7. Do the plans include design loads as required under the Uniform Building code for roof snow loads, (a minimum of 40 pounds per square foot in Garfield County) floor loads and wind loads? Yes _V" No n Not necessary for this project 12, 8. Does the plan include a building section drawing indicating foundation, wall, floor and roof construction? Yes _ No m Not necessary for this project (2) 9. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes _(/ No m Not necessary for this project (2) 2 10. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes _L/ No in Not necessary for this project (2) 11. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span bet�v een the ridge and the eave down to existing grade contours? Yes v No m Not necessary for this project ( ) 12. Does the plan include any stove or zero clearance fireplace p lanned for installation including make and model and Colorado Phase II certifications or phase lI EPA certification? / /� Yes No n ✓ ) Not necessary for this project (2) 13. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter 37? Yes No in Not necessary for this project _(-�z 14. Does the plan include a window schedule or other verification that egress /rescue windows from sleeping rooms and /or basements comply with the requirements of the Uniform Building Code? Yes __VI No in Not necessary for this project (2) 15. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes _f C No in Not necessary for this project (2) 16• Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes No in Not necessary for this project _ __(2) 17. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes No in Not necessary for this project V 18 Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from that association, if required by that association, prior to submitting an application for a building permit? Yes No i Not necessary for this project 3 19. Have two (2) complete sets of constructions drawings been submitted with the application? Yes No r/,,, Not necessary for this project (2) 20. Is this an application for the placement of a manufactured home? Yes No If yes, have you specified the size of the unit; live roof load; foundation design; method of anchoring? Yes No (1) Not necessary for this project (2) 21. Have you designed or had this plan designed while considering building and other construction code requirements? Yes L No (+) 22. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield Building Department? Yes _ 1�' No (s) 23. Do you understand that approval for design and /or construction changes are required prior to the application of these changes? Yes No („ 24. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit Fee" as well as any "School impact" or "Septic system " fees required, at the time you pick up your building permit:? Yes �l No a 25. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes _ (/ No („ 26. Are you aware that the person signing the Permit Application whether the "Owner ", "Agent of the Owner ", "General Contractor ", "Contractor" or otherwise, signing the application is the party responsible for the project complying with the Uniform Codes ". Yes _ No (n (CONTINUED ON NEXT PAGE) 4 I I hereby acknowledge that I have read, understand and answered these questions accurately to the best of my ability. 4 �� � ev 7- • 9r signatr date Phone: 876 -Se3( (days); 376-Sosic (evenings) • Project Name: TWO ems . q,Q- .G _e • Project Address: 42 37 C, (e .302 5 //¢ ('r) 3/(52. Notes: - (1) If you have answered No on any of these questions you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in Issuing the permit are to be expected. Work may not proceed without the issuance of the permit. • (2) If you have answered 'Not necessary for this project' on any of the questions and it is determined by the Building Official that the information Is necessary to review the application and plans to determine • minimum compliance with the adopted codes, please expect the following: • A. The application may be placed behind more recent applications for building permits in the review process and not reviewed until required Information has been provided and the application rotates again to first position for review. B. Delay in issuance of the permit. C. Delay in proceeding with construction. (3) If you answered No to this question the circumstances described in the question could result in a "Stop Work Order being issued or a'Certificate of Occupancy' not being Issued. PerApp01.95 Effective June 1, 1995 5 • i J . : 'n .:.4,161 J,:,iJJ JJ4:14� id - :ei r .'.a/ -/l JJJ.; .4 .;J<d Jd J ila..u'a i THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BULDING PERMIT A FIELD COUNTY, COLORADO Date Issued . -- - --. Zoned Area Permit No.S » AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of e above described structure, the permit may then be revoked by notice from t ount ling 6 IM EDIATELY BECOME NULL AND VOID, Use . Address or L al Descriptio f :Z. + 1 Owner e / /c. " `�, ,.t g �y' Contractor 044.14 Setbacks Front Side Side Rear This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection. INSPECTION RECORD Zoning Roof Covering Electric -Final (by STATE inspector) Footing i, c (l(1 4 r 95 Foundation Plumbing- Underground Gas Piping Heating Ventilation Frame i- =1 -° %t '4-- Insulation Plumbing -Rough Drywall Electric -Rough (by STATE inspector) Final /_ g—iL A-C. ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING — WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 945 -8212 1119 8th Street, County Courthouse, Glenwood Springs, Colo. APPI,OKE D DO NI DESTR Y THIS CARD