Loading...
HomeMy WebLinkAbout5652 No. 5652 GARFIELD COUNTY BUILDING, SANITATION and PLANNING DEPARTMENT 109 8th Street Suite 303 Glenwood Springs, Colorado 81601 (303) 945 -8212 Job Address 0147 Do3ores ;ir "?.e.. We =.th.lnk 'axiell Glenwood S.ri • Nature ofWork ui Blding Use of Building Single Family Dwelling W /Double Garage o wncr Darrel & Hattie Norgren Contractor Alpine CW, Inc. Amount of Permit$ 1,676.75 Dale August 29, 1995 Permit: 1016.22 Plan . 660.53 Paid $660.53 8 -9 -95 S. Archuleta Clcrk BUILDING PERMIT APPLICATION OARFIELD COUNTY, COLORADO Applicant to complete numbered spaces only. PERMIT NO.56 P ARCEL/SCHED NO. ___ - Joa ADDRESS 01/{7 DOLORES CIRCLE, GLENWOOD SPRINGS, CO 1 LEGAL LOT NO. BLOCK SUBDIVISION DESCR. Five (5) Westbank_.Ranch P.U.D. - filing 4l 2 OWNER Darrel & Hattie Norgrer ADDRESSuenv er , . �� S P H . $S 0212 /.21_Q (30 936 WKPH - 3 CONTRACTOR Alpine CM, Inc. ADDRESS ran S Jct., 81501 P 4 4.5 — 505 LICENSE NO 4 ARCHITECT OR DESIGNER S ame ADDRESS Same PH. Same LICENSE NO. 5 L.J. Lindauer Inc. ADDRESoG a n d 9d qg7 Ave 81501 P �41 LICENSE NO. 28331 6 S.F OF BUILDING 3129 S.F OF LOT 59242 HEIGHT 29 , NO. OF FLOORS 3 7 USE OF BUILDING Single family residence 8 CLASS OF WORK: XNEW ['ADDITION n ALTERATION aREPAIR oMOVE uREMOVE 9 DESCRMEWORK. Construction of a 2 -story with walk -out basement single family dwelling. (Ea. 5 / 10 GARAGE ( DOUBLE DRIVEWAY PERMIT ON SITE SEWAGE DISPOSAL PERMIT SITE PLAN 11 VALUATION OF WORK: $ 207, 634.86 ADJUSTEDVAL.$ PLAN CHECK FEE 4O. S3 I PERMIT F! Q) v , .2 2 SPECIAL CONDITIONS: SCHOOL IMPAQ E NO. OF BUILDINGS ON USE OF BUILDINGS NOW ON q � ' / PARCEL PARCEL TOTAL FE # 7 7 73- OCO. GR. CONST. TYPE NOTICE WATER SUPPLY DATE PERMIT ISSUED - f' SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING. SPECIAL APPROVALS REQUIRED RECEIVED NOT REQUIRED THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS ZONING NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED • OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. HEALTH DEPT. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES FIRE DEPT. GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED - — HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE SOIL REPORT AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF SETBACKS COr .. %" � . (Date) ra l9 t IV illft i, nature o ner, • . rector or authorized :gent h. • _•:.da f' ,.. notice above. FLOOD HAZARD / 0.. • • p ,^ 2,46 Z MANUF. HOME — - Building Department Approve /.: Le Q 9 Planning Department Approval/date OTHER • AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND /OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER, BUILDER AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Garform.003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE IN IAL 1 al i40--3 • GARFII LD COUNTY RUILDING AND PLANNING MINIMUM APPLICATION REQUI1tEMENTS for SIl1GI,li FAMILY DWELLING CONSTRUCTION including NEW CONSTRUCTION A1)1)fTIONS ALTERATIONS and MOVED BUILDINGS • In order to understand the scope Of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. Adequate and complete information will prevent delays in the plan review process. Reviewing a plan and the discovery that required information has not been provided by the applicant may result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor may be required to provide this information before the plan review may proceed. This causes delays because other plans that are in line. for review may he given attention before the new information may he reviewed after It has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. If you do not, it may be helpful to obtain a book titled 'Dwelling construction under the Uniform Building Code. This book is available to you through this department at our cost. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following check list prior to and during design. Applicants are required to indicate appropriately and to submit completed check list at time of application fora permit: • 1. Is a site plan included that indicates the distance of the proposed building or addition to property lines, other buildings, set back . easenu tls and utility easements? Yes • _ No in Not necessary for this project ____ _22) 2. Does the site plan include the location of the LS.D.S. (Individual Sewage Disposal System) and the distances to properly lines, wells (on subject properly and adjacent properties) , streams or water courses? Yes No u) Not necessary for this project a) 13. Does the site plan indicate Ilse location and direction of Ilse County or private road accessing the property? Yes- No _____, Not necessary for this project (2) 4 Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building code or per snooped engineered design? Yes _le_ No „) Not necessary for this project 5. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and Ilse clearances required between woocl and ear II? Yes No Not necessary for this project 0) 6. Do the plans indicate the size an location of ventilation Openings for the attic, roof joist spaces and soffits? Yes _V_ No in Not. necessary for this project (2) 7. Do the plans include design loads as required under the Uniform Building code for roof snow loads, ( a minimum of 40 pounds per square foot in Garfield County) floor Toads and wind loads? Yes _V_ No (n Not necessary for Ibis project. (2) 8. Does the plan include a building section drawing indicating font ion, wall, floor and roof construction? Yes No --___ n Not necessary for this project (2) 9. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or musses? Yes _V_ No ,n Not necessary for this project (2) 10. Does the building section drawing or other detail include the method of positive connection of all columns and beams? 2 Yes No (U Not necessary for this project (2) 11, Does the plan indicate the (height of the building or proposed addition from-the (highest point of the building or addition measured at mid span between Ilse ridge and the cave down to existing grade contours? Yes V. No (,) Not necessary for this project (21 12. Does Ilse plan include any stove or zero clearance fireplace planned for installation including slake and model and Colorado Phase II certil Lions or phase 11 EPA certification? Yes No in Not necessary for this project (2) 13. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter :37? Yes __ -_ -- No _1(1) Not. necessary for this project V m 14. Does.tibe Plan Include a window schedule or other verification that egress /rescue windows from sleeping rooms and /or basements comply with the requirements of the Uniform Building Code? Yes _y_ No m Not necessary for dais project (2) 15. Does the plan include a window schedule or other verification that windd s provide natural light and ventilation for all habitable rooms? Yes V No (u Not necessary for this project (2) t6. Do tlnetplans indicate the location of glazing subject to human impact such ?s glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes _ e_ No ,u Not necessary for this project (2) 17. Is the location of all nat and liquid petroleum gas furnaces, boilers a red water heaters indicated 011 the plan? Yes Apr_ No ( 1 ) Not necessary for this project („ 18. Ilave two (2) complete sets of constructions drawings been submitted with the application? Yes je No („ Not necessary for this project (2) 19. 1lave you designed or had this plan designed while considering buildin r and other construction code requirements? Yes No („ • 20. Does the plan accurately indicate what you intend to construct and wlistl. will receive a final inspection by the Garfield Building Department? Ycs ]/ No 21. no you understand that approval for design anti /or construction chttirtges "ae required 11rio1_to (he application of these changes? Yes _ No 22. 1)o you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be regitired to pay the "Permit Pet" as well as any "School impact" or "Septic system " fees required, at the time you pick up your building permit? Yes _ No 23. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a_ final inspection - print' to receiving a Certificate of Occupancy and occupaiy of the building"? Yes __ -- No - - - - -'n 24. Are you aware Iha( the person signing the Permit. Application whether the "Owner" "Agent of the Owner" "General Contractor" "Contractor" or otherwise, signing the application is the party responsible for the protect :omplying with the Uniform Codes "" Ycs - No I hereby acknowledge that I have read, understand and answered these clinestions accurately to the hest of any ability, i - , sihnalurc - - - -- b date Phonct\47bJ45.Z (clays), c91o)?,q5 �4 (evenings) Project Nall' e. Jlf p� -°- = � - - - - -- - - = Esc -�� -- Project Address: 4 • o • Notes: (I) If you have answered "No' oil any of these questions you' nay be required to provide this Information al Ilse request of the nun Wing 011lcht! prior to beginning the plan review process. Relays In Issuing the permit ate to be expected. Work may not in nceed without the Issuance of the permll. ( If you have answered "Ilot necessary for 11115 project on any of the questions and II Is determined by the Iuilding Official That the hdormadml Is necessary to review the application and plans to determine minimum compliance svltlr the adopted codes, please expect the following: A. "flre nppllcnlloo may be placed hehhid more recent applications for building permits In the review pl ocess and nut 1eviewed milli required InlorrontInit has been provided and the application rotates again to firs( position for review. It, Delay In Issuance of the pet snit. C. Delay In pmocceding whit cunsItictlun. ( If you answerer) "110 to this question We cnculnsl our es described In the question could result 10 a "Slop %York Diner being Issued or O'Cei llticalc of Occupancy' 1101 being Issued. Effective May I, 1994 isaihtshi t1.44 J' ijtit dddd.i. J4Q II as; whist: 0111i.:L THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS i BUILDING PERMIT ;AFIELD COUNTY, COLORADO Date Issue.... Zoned Area r Permit No AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the bove descri ed structure, the p mit may hen be r ked by notice from t o 1 I an ME� }�1(� L AND VO ao Use -a• ( ((s�t f � ! Addr= • egalDescri•lion * J 41 0 e OS Own:( 1� , i . 1 1 Contractor is Alt - Setbacks Front Side Side Rear This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection. I INSPECTION RECORD Zoning Roof Covering 125 eu j4-r /c - s- 5s ,. Electric -Final (by STATE inspector) ' Footing et_ A 7-9A - k,..„, Foundation,'n"" "d"°` le/e6 -°4 fr anosz s m s ffetr4 x /J / /sK 1 o -/ p ° �"" i I Plumbing- Underground Gas Piping 0 4 h -22 -T. T,v.--e Heating Ventilation 1 Frame / - 4-- 96, Insulation / -76 Tni ra /se /3 39. --24' 1 Plumbing -Rough kt -22-is J i,..6 Drywall A ' - yr -1- ' vO ��^r i _z y-�� s```-� c'.UT l '-dpi' � /te is ry . Electric -Rough 1 1 - ye (by STATE inspector) T;C. ; Final .f- -4t -qq / ` ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING — WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. / THIS PERMIT IS NOT TRANSFERABLE Phone 945 -8212 10 9 8th Street; County Courthouse, Glenwood Springs, Colo. APPROVED DO NOT DESTROY THIS CARD Date ei CBYAi2 N O N 0 4 (-f O bU O O N N n O d p Lo n U a) a ti u « Q a) a) i n �r-! O U > N N ",7 W _4, O o O O • N � d n p N w co a) N n v V o r \ n N V 0) LO o m 0 m •" 0 - 4 .O. N • in 4-1 . O ti y V [� 'b ~ I Cd (n CI V i 01 crl Q 0 r-1 CO 0.∎ i.. kale t a --1 -H N p Cs/ O t--, up a p li 4 'b N O r 'J N > O VI oTh o v 0 Q �'� r co 50 01 g 40 en Imo' V] y am - ',, 0 - b r c.) g U r a U ' . U 1.1011111, rro■) 0 V1 a) 40 01 z oAG] F"+ 0 G C-', r te ' 18114 �I 0 q 0 'd 0 0A • ry b p m w g m toe Cos a) ') H p+ ou c7 p p A 0 O v F--1 -4-) O q ,---{ 'Ed cQ b q 4-■ >' ' 0 U co ca Q , a) ,H >. 4-I c2 �w °�. x m p a 0 o W al H d C d v U w o 0 V ++ PC 1.4 U rn 09 m 0 U /.— Q 0 'C 0 . w o ry N :4 0 cn ro p p c) o � O y q d . �- (� "-) n " O o +J cu S v CI U cu' '6 U +' u on w a) bU m 0 bf) v 0 u' �i a? U R. s, R 3 �) a b c b CI CU "CJ 7 , o E D 0 0 CQ U CQ F: 0 0