Loading...
HomeMy WebLinkAbout1.05 Engineers report for ISDS repair.pdfAttachment "E'' ) .. ', .. 6 SCHMUESER GORDON i MEYER ENGINEERS SURVEYORS July 26, 2005 Mr. Ron Vanmeter Garfield County Building Department 108 8'" Street, Suite 201 Glenwood Springs CO 81601 RE: Sopris RV Park Application for Repair of ISDS Dear Ron: I I 8 W 6TH, SUITE: 200 GLENWOOD SPRI~GS, CO 6 I 60 I 9 70·94 5· I 004 FX 970·945·5948 ASPEN PO BOX 2155 ASPEN, CO 81612 970·925·6727 l"RC TED E;l TT[ P 0 BOX 3088 970-:349·5355 F)( 970·925·4157 f"X 970·349·5358 This is to transmit an application for the repair of the above-referenced ISDS system. This is to also follow up on conversations and correspondence I have had with both yourself and Steve Hackett over the last several months concerning our involvement in finding a solution to the problems with the system earlier this year. By way of history, it was determined last spring that liquid, either effluent or raw sewage, from the northerly or leach field A of the Sopris RV Park was being discharged to the surface. The owners of the Sopris RV Park, Stanley and Valeria Koziel, took immediate steps to address the problem. This office was contacted to assist them in analyzing the situation. The Koziel's also immediately decreased the water usage in the RV park. Since the original discharge was noted, I have been on site approximately six different times. At no time has there been additional discharge of liquid to the ground surface and, therefore, there has been no additional potential negative impact to the public health of either the residents of the RV park of other persons using the property. After investigation alternatives, it has been concluded that the likely cause of the discharge was excessive use of water within the RV park and physical damage to the disposal field, both of which resulted in an overloading of the disposal field. Please note that we also revisited the possibility of connecting the Sopris RV Park to the Town of Carbondale wastewater treatment facility. The Town was not actually contacted. While the RV park is located directly across the Roaring Fork River from the wastewater treatment facility, the Sopris RV Park ISDS system itself is located some 500 horizontal feet from the wastewater plant. From a practical standpoint, connection would actually require on the order of 1500 feet of line to be laid, including a river crossing of the Roaring Fork River. It becomes apparent that that alternative is cost prohibitive for this property. Attached is an application form for the repair as well as a $50 permit fee. It is the intent of the owners to totally remove the existing disposal field and replace it in place. Therefore, it is not possible to do percolation tests at the site. Also attached hereto is the packet, which was prepared by the Garfield County Planning Department for the Board of County Commissioners meeting on July 17, 1995. In that packet is a report prepared by Enartech dated December 21, 1994, which provides the technical information required in the pemnit form. That report lists the design flows, has a site plan attached and provides a typical detail for leach field A Please note that leach field A is 2304 square feet and receives pumped effluent from a series of septic tanks. l.\2005\2005-39617-26-Q511r lo Vanmeter doc 6 Jply 26, 2005 Mr.· Ron Vanmeter Page 2 An additional attachment is the original application for leach field A signed by Peter Belau, P.E., December 21, 1994. Note that the perc rates in three test holes were 24 mpi, 27 mpi and 95 mpi. If you require additional information, please make that request directly with the Koziel's. I will assist \hem in providing such information as necessary. Respectfully submitted, SCHMUESER GORDON MEYER, INC. DWG:Iec\2005-396.001 Attachments cc: Stanley and Valerie Koziel. w/o attachments I \2005\2005-396\7-25-05 Hr ~o V~IYT}e!er doc pd$50°(?, ~-. .~-' 05 ~\.;lid GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 108 Eighth Street, Suite 201 Glenwood Springs, Colorado! 81601 Phone (970) 945-8212 INDIVIDUAL SEWAGE DISPOSAL PERMIT PROPERTY Permit 4088 A•sessor's Parcel No. This does not constitute a buildmg or use permit. Owner's Name&li;'>r IS B J Y~esent Address _W_,_""-'-:~ffi~\l";--,.----Phone Sto~-O\to~ System Location Olo4 D c.Q \ D6 c I d& Legal Description of Assessor's Parcel No. ______;"; ).___,;3"-q-'--'3"---·"oZ'"""8'.._C{_.__-_6_0 _-_0::._:./_~-----------SYSTEM DESIGN ______ Septic Tank Capacity (gallon) ______ Other ______ Percolation Rate (minutes/Inch) Number of Bedrooms (or other) ____ _ Required Absorption Area -See Attached ~ lo Special Setback Requirements: Date ________ _ Inspector ___ _ FINAL SYSTEM INSPECTION AND APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering lnstalla~ System Installer__ ;c_fL_ Lm&r Septic Tank Capacity ___________7-tt1--~~::::l,f"-'<c6,.,;:------'-.~'::J,-..~-u,_7{L.:i'-_.2_.,i.p.fJ-t-__2j--'--'QC-"'-6-~'------SeptiC Tank Manufacturer or Trade Name ___ _,A-:5J~--1Ud.w~=~-· f-:.,l"t"''"'~=~--'(:;~,u!,l""'V~i4!.41..JJ'->4,rtf.L~-"""'"---''----1[['-'-'-) ____ _ Septic Tank Access within 8" of surtace ----~Dd..-4-<4>4~"'---'G'='-"'LI)(.,...I,_),&_J.,'("r---\:--'-'"t'-1'-f£ -.vu.._.,=>,___.l.,"~l"!(,""-'~-------l/Absorption Area K U fh tt£42 4f lu)'LO/~ 'jo Yr~,_\ Absorption Area Type and/or Manufacturer or Trade Name __ An-,UL'-I<f!J-__ ~d--·'-''-'-c~r.---f-P·"-~?1'-l' \-J-1 ,_,tif...M1'-""""-'-"Id£c="'=~J'---Adequate compliance with County and State regulations/requirements _.MJ,._ -~-~ Othar ___ _ Date ______ _ _ ___ Inspector ___________________________ _ RETAIN WITH RECEIPT RECORDS 1\T CONSTRUCTION SITE •CONDITIONS: 1. AI! Installation must comply w1th all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit is valid only tor connectlon to structures which have fully complied with County zoning and building requirements. Connection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who conslructs. alters, or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or speclflca1Jons contained In the application of permit commits a Class I, Petty Offense ($500.00 fine-6 months In jail or both). \ol/1-.,• Ann1 ''"'~•,.,. INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION O~R U'>~iShW~ ti&~ 6 ADDRESS 06lfQ [(X{ n~ <( fl /at" PHONE Cf (0 -Cf'£J-O/_3 CONTRACTOR "DC\ v [. d I H i c I< 5 -_/c. ADDRESS 3-5).0 5 G"bhJ ltv PHONE qq£,-;;2.) ,_s1 'f6_3'-2/82 PERMITREQUESTFOR NEWINSTALLATION ALTERATION ~ Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4). LOCATION OF PROPOSED FACILITY: Near what City of Town Qft.t.6.;," V"r l£ Size of Lot Legal Description or Address WASTES TYPE: ~ ~ ~ COMMERCIAL OR INDUSTRIAL NON-DOMESTIC WASTES OTHER-DESCRIBE BUILDING OR SERVICE TYPE: Number ofBedroomsc::;,;. f\:rTf'Ute:P 1B:. · ,}1, 11 'i-1-~'!{Number of Persons _ _ Garbage Grinder Automatic Washer SOURCE AND TYPE OF WATER SUPPLY: ~ Dishwasher SPRING STREAM OR CREEK If supplied by Community Water, give name of supplier: DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: !i""o c ; -~ 1\l]ilo:Jo::J Urrea. ' Was an effort made to connect to the Community System? i-e; · A site plan is required to be submitted that indicates the following MINIMUM distances: Leach Field to Well: 100 feet Septic Tank to Well: 50 feet Leach Field to Irrigation Ditches, Stream or Water Course: 50 feet Septic System (septic tank & disposal field) to Property Lines: 10 feet YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITHOUT A SITE PLAN. GROUND CONDITIONS: Soc i'«rffic,.~ ~a . ..>-', 1'1 ~ f-E NC,;Nc<:)C•~ f:.c,y·"-'f · Depth to first Ground Water Table Percent Ground Slope J TYPE OF INDNIDUAL SEW AGE DISPOSAL SYSTEM PROPOSED: 2 ... ~ · VAULTPRIVY AERATION PLANT COMPOSTING TOILET INCINERATION TOILET VAULT RECYCLING, POTABLE USE PIT PRIVY RECYCLING, OTHER USE CHEMICAL TOILET OTHER-DESCRIBE. _____________ _ FINAL DISPOSAL BY: @oRPTION TRENCH, BED ORP~ UNDERGROUND DISPERSAL ABOVE GROUND DISPERSAL EVAPOTRANSPIRATION SAND FILTER WASTEWATER POND OTHER-DESCRIBE. _______________________ _ WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? * . PERCOLATION TEST RESULTS: (To be completed by Registered Professional Engineer, if the Engineer does the Percolation Test) S'e<;< \ "l'\ \ /'w>ru c-n"t<l J ~ l.ldl. Minutes. ____ ___yer inch in hole No. 1 Minutes _____ _.per inch in hole NO. 3 Minutes. ____ _..er inch in hole No. 2 Minutes _____ __.,er inch in hole NO. Name, address and telephone of RPE who made soil absorption tests: --------------Name, address and telephone ofRPE responsible for design of the system:-----------Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional tests and reports as may be required by the local health department to be made and furnished by the applicant or by the local health department for purposed of the evaluation of the application; and the issuance of the penni! is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made, information and reports submitted herewith and required to be submitted by the applicant are or will he represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of healtli in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any falsification or misrepresentation may result in the denial of the application or revocation of any penni! granted based upon said application and in legal action for peijury as provided by law. ""'"' \~1, ,;,_ Date_1'----=-2-'-7_-_0_~=----PLEASE DRAW AN ACCURATE MAP TO YOUR PROPERTY!! 3